Skip to code content (skip section selection)
Compare to:
San Francisco Overview
San Francisco Charter
San Francisco Administrative Code
ADMINISTRATIVE CODE
THE SAN FRANCISCO CODES
PREFACE TO THE ADMINISTRATIVE CODE
CHAPTER 1: GENERAL PROVISIONS
CHAPTER 2: BOARD OF SUPERVISORS
CHAPTER 2A: EXECUTIVE BRANCH
CHAPTER 2B: ASSESSMENT APPEALS BOARDS (TAX APPEAL BOARDS)
CHAPTER 3: BUDGET PROCEDURES
CHAPTER 4: CITY BUILDINGS, EQUIPMENT, AND VEHICLES
CHAPTER 5: COMMITTEES
CHAPTER 6: PUBLIC WORKS CONTRACTING POLICIES AND PROCEDURES
CHAPTER 7: DISASTER COUNCIL
CHAPTER 8: DOCUMENTS, RECORDS AND PUBLICATIONS
CHAPTER 9A: FARMERS' MARKET
CHAPTER 9B: FLEA MARKET
CHAPTER 10: FINANCE, TAXATION, AND OTHER FISCAL MATTERS
CHAPTER 10A: [REQUEST FOR SHERIFF’S SERVICES]*
CHAPTER 10B: SPECIAL LAW ENFORCEMENT AND PUBLIC WORKS SERVICES
CHAPTER 10C: REIMBURSEMENT FOR TOWING AND STORAGE OF VEHICLES
CHAPTER 10E: PLANNING MONITORING
CHAPTER 10F: 1660 MISSION STREET SURCHARGE
CHAPTER 10G: BOARD OF APPEALS SURCHARGE FOR PERMITS AND FEES
CHAPTER 10H: RECOVERY OF COSTS OF EMERGENCY RESPONSE
CHAPTER 11: FRANCHISES
CHAPTER 12: HOUSING AUTHORITY
CHAPTER 12A: HUMAN RIGHTS COMMISSION
CHAPTER 12D: MINORITY/WOMEN/LOCAL BUSINESS UTILIZATION
CHAPTER 12E: BAN ON CITY USE OF GAS-POWERED LANDSCAPING EQUIPMENT
CHAPTER 12F: IMPLEMENTING THE MACBRIDE PRINCIPLES - NORTHERN IRELAND
CHAPTER 12G: PROHIBITION ON USE OF PUBLIC FUNDS FOR POLITICAL ACTIVITY BY RECIPIENTS OF CITY CONTRACTS, GRANTS, AND LOANS
CHAPTER 12H: IMMIGRATION STATUS
CHAPTER 12I: CIVIL IMMIGRATION DETAINERS
CHAPTER 12J: CITY BUSINESS WITH BURMA PROHIBITED
CHAPTER 12L: PUBLIC ACCESS TO RECORDS AND MEETINGS OF NONPROFIT ORGANIZATIONS
CHAPTER 12M: PROTECTION OF PRIVATE INFORMATION*
CHAPTER 12N: LESBIAN, GAY, BISEXUAL, TRANSGENDER, QUEER, AND QUESTIONING YOUTH: YOUTH SERVICES SENSITIVITY TRAINING
CHAPTER 12S: WORKING FAMILIES CREDIT PROGRAM
CHAPTER 12Y: SAN FRANCISCO SLAVERY DISCLOSURE ORDINANCE*
CHAPTER 13: JAILS AND PRISONERS
CHAPTER 14A: DISADVANTAGED BUSINESS ENTERPRISE PROGRAM
CHAPTER 14B: LOCAL BUSINESS ENTERPRISE UTILIZATION AND NON-DISCRIMINATION IN CONTRACTING ORDINANCE
CHAPTER 14C: [EXPIRED]
CHAPTER 15: MENTAL HEALTH SERVICE
CHAPTER 16: OFFICERS AND EMPLOYEES GENERALLY
CHAPTER 17: PUBLIC OFF-STREET PARKING FACILITIES
CHAPTER 18: PAYROLL PROCEDURE
CHAPTER 19. PUBLIC SAFETY CAMERA ORDINANCE
CHAPTER 19A: PUBLIC HEALTH
CHAPTER 19B: ACQUISITION OF SURVEILLANCE TECHNOLOGY
CHAPTER 20: SOCIAL SERVICES
CHAPTER 21: ACQUISITION OF COMMODITIES AND SERVICES
CHAPTER 21A: HEALTH-RELATED COMMODITIES AND SERVICES
CHAPTER 21B: COMMODITIES AND SERVICES RELATING TO PROJECTS ADDRESSING HOMELESSNESS
CHAPTER 21D: FOOD PURCHASES AT HOSPITALS OPERATED BY THE DEPARTMENT OF PUBLIC HEALTH AND JAILS OPERATED BY THE SHERIFF’S DEPARTMENT
CHAPTER 21E: GOODS OR SERVICES CONTRACTS FOR INCARCERATED PERSONS
CHAPTER 21F: SAN FRANCISCO PUBLIC UTILITIES COMMISSION SOCIAL IMPACT PARTNERSHIP PROGRAM.
CHAPTER 21G: GRANTS
CHAPTER 21H: PROCUREMENT OF FIREARMS AND AMMUNITION
CHAPTER 22: RADIO COMMUNICATION FACILITIES
CHAPTER 22A: INFORMATION AND COMMUNICATION TECHNOLOGY
CHAPTER 22B: TELECOMMUNICATIONS FACILITIES
CHAPTER 22C: PUBLIC INTERNET ACCESS
CHAPTER 22D: OPEN DATA POLICY
CHAPTER 22E: CITY-OWNED FIBER-OPTIC FACILITIES
CHAPTER 22G: OFFICE OF EMERGING TECHNOLOGY
CHAPTER 22H: DESIGNATION UNDER HEALTH INSURANCE PORTABILITY AND ACCOUNTABILITY ACT (HIPAA)
CHAPTER 22I: OFFICE OF CYBER SECURITY AND DUTIES OF THE CHIEF INFORMATION SECURITY OFFICER
CHAPTER 23: REAL PROPERTY TRANSACTIONS
CHAPTER 23A: SURPLUS PUBLIC LANDS ORDINANCE
CHAPTER 24: REDEVELOPMENT AGENCY
CHAPTER 24A: ADMINISTRATIVE STRUCTURE LOCAL RENT SUPPLEMENT PROGRAM IN THE OFFICE OF MAYOR
CHAPTER 24B: RELOCATION APPEALS BOARD
CHAPTER 25: STREET LIGHTING
CHAPTER 26. [RESERVED]
CHAPTER 27: HEALTHY NAIL SALON RECOGNITION PROGRAM
CHAPTER 28: ADMINISTRATIVE DEBARMENT PROCEDURE
CHAPTER 29: FINDINGS OF FISCAL RESPONSIBILITY AND FEASIBILITY
CHAPTER 29A: APPROVAL OF POWER PLANT; PLANNING CODE SEC. 303(q) CRITERIA
CHAPTER 29B: CHILD CARE FEASIBILITY STUDY FOR CITY AND CITY-FUNDED PROJECTS
CHAPTER 30: CENTRALIZATION OF WORKFORCE DEVELOPMENT
CHAPTER 31: CALIFORNIA ENVIRONMENTAL QUALITY ACT PROCEDURES AND FEES
CHAPTER 32: RESIDENTIAL REHABILITATION LOAN PROGRAM
CHAPTER 33: COMMISSION ON THE STATUS OF WOMEN
CHAPTER 33A: LOCAL IMPLEMENTATION OF THE UNITED NATIONS CONVENTION ON THE ELIMINATION OF ALL FORMS OF DISCRIMINATION AGAINST WOMEN (CEDAW)*
CHAPTER 34: NOTIFICATION TO ASSESSOR CONCERNING ZONING RECLASSIFICATIONS OF PROPERTY, CONDITIONAL USE PERMITS AND VARIANCES
CHAPTER 35: RESIDENTIAL, HOTEL, AND PDR COMPATIBILITY AND PROTECTION
CHAPTER 36: COMMUNITY IMPROVEMENTS AREA PLANS AND PROGRAMS
CHAPTER 37: RESIDENTIAL RENT STABILIZATION AND ARBITRATION ORDINANCE
CHAPTER 37A: RENT STABILIZATION AND ARBITRATION FEE
CHAPTER 37B: MIDTOWN PARK APARTMENTS
CHAPTER 37C: EVICTION PROTECTIONS FOR COMMERCIAL TENANTS DURING COVID-19 PANDEMIC
CHAPTER 38: COMMERCIAL LANDLORDS; ACCESS IMPROVEMENT OBLIGATIONS AND NOTICE TO SMALL BUSINESS TENANTS REGARDING DISABILITY ACCESS
CHAPTER 39: [RIGHT TO RETURN TO REVITALIZED PUBLIC HOUSING]
CHAPTER 40: HOUSING CODE ENFORCEMENT LOAN PROGRAM
CHAPTER 41: RESIDENTIAL HOTEL UNIT CONVERSION AND DEMOLITION
CHAPTER 41A: RESIDENTIAL UNIT CONVERSION AND DEMOLITION
CHAPTER 41B: COMMUNITY OPPORTUNITY TO PURCHASE ACT
CHAPTER 41C: TIME-SHARE CONVERSION ORDINANCE
CHAPTER 41D: RESIDENTIAL HOTEL VISITOR POLICIES
CHAPTER 41E. RESIDENTIAL HOTEL MAIL RECEPTACLE ORDINANCE
CHAPTER 41F: TOURIST HOTEL CONVERSION*
CHAPTER 41G: RESIDENTIAL HOTEL COVID-19 PROTECTIONS
CHAPTER 42: INDUSTRIAL DEVELOPMENT AUTHORITY
CHAPTER 43: MUNICIPAL FINANCE LAW
CHAPTER 44: ADULT DAY HEALTH CARE PLANNING COUNCIL
CHAPTER 45: JURY FEES
CHAPTER 47: PREFERENCE IN CITY AFFORDABLE HOUSING PROGRAMS
CHAPTER 48: RENTAL SUBSIDY PROGRAM FOR LOW-INCOME FAMILIES
CHAPTER 49: SECURITY DEPOSITS FOR RESIDENTIAL RENTAL PROPERTY
CHAPTER 49A: RESIDENTIAL TENANT COMMUNICATIONS
CHAPTER 49B: RESIDENTIAL RENTAL UNITS: LOCK REPLACEMENTS BY LANDLORD WHEN TENANTS VACATE
CHAPTER 50: NONPROFIT PERFORMING ARTS LOAN PROGRAM
CHAPTER 51: VOLUNTARY ARTS CONTRIBUTIONS PROGRAM
CHAPTER 52: SAN FRANCISCO CARBON MITIGATION PROGRAM
CHAPTER 53: URBAN AGRICULTURE
CHAPTER 53A: URBAN AGRICULTURE INCENTIVE ZONES ACT PROCEDURES
CHAPTER 54: SOUTHEAST COMMUNITY FACILITY COMMISSION
CHAPTER 56: DEVELOPMENT AGREEMENTS
CHAPTER 57: FILM COMMISSION
CHAPTER 58: RIGHT TO COUNSEL IN CIVIL MATTERS
CHAPTER 58A: RIGHT TO CIVIL COUNSEL FOR VICTIMS OF DOMESTIC VIOLENCE
CHAPTER 59: HEALTHY FOOD RETAILER ORDINANCE
CHAPTER 59A: FOOD SECURITY AND EQUITY REPORTS
CHAPTER 60: ASSISTED HOUSING PRESERVATION ORDINANCE
CHAPTER 61: WATERFRONT LAND USE
CHAPTER 62: DOMESTIC PARTNERSHIPS
CHAPTER 63: WATER EFFICIENT IRRIGATION ORDINANCE*
CHAPTER 64: CITY EMPLOYEE AND CITY CONTRACTOR SAFETY AND HEALTH
CHAPTER 65: RENT REDUCTION AND RELOCATION PLAN FOR TENANTS INCONVENIENCED BY SEISMIC WORK PERFORMED PURSUANT TO CHAPTERS 14 AND 15 OF THE SAN FRANCISCO BUILDING CODE
CHAPTER 65A: COMPENSATION, OR SUBSTITUTE HOUSING SERVICE, FOR TENANTS AFFECTED BY TEMPORARY SEVERANCE OF SPECIFIED HOUSING SERVICES DURING MANDATORY SEISMIC WORK REQUIRED BY BUILDING CODE CHAPTER 34B
CHAPTER 66: SEISMIC SAFETY RETROFIT PROGRAM
CHAPTER 67: THE SAN FRANCISCO SUNSHINE ORDINANCE OF 1999
CHAPTER 67A: CELL PHONES, PAGERS AND SIMILAR SOUND-PRODUCING ELECTRICAL DEVICES
CHAPTER 67B: PARENTAL LEAVE AND TELECONFERENCING
CHAPTER 68: CULTURAL EQUITY ENDOWMENT FUND
CHAPTER 69: SAN FRANCISCO HEALTH AUTHORITY
CHAPTER 70: IN-HOME SUPPORTIVE SERVICES PUBLIC AUTHORITY
CHAPTER 71: MILLS ACT CONTRACT PROCEDURES
CHAPTER 72: RELOCATION ASSISTANCE FOR LEAD HAZARD REMEDIATION
CHAPTER 74: RENT ESCROW ACCOUNT PROGRAM
CHAPTER 77: BUILDING INSPECTION COMMISSION APPEALS
CHAPTER 78: DEPARTMENT OF BUILDING INSPECTION PERMIT TRACKING SYSTEM
CHAPTER 79: PREAPPROVAL NOTICE FOR CERTAIN CITY PROJECTS
CHAPTER 79A: ADDITIONAL PREAPPROVAL NOTICE FOR CERTAIN CITY PROJECTS
CHAPTER 80: ANTI-BLIGHT ENFORCEMENT PROCEDURE
CHAPTER 80A: ORDERS TO VACATE DUE TO HAZARDOUS HOUSING CONDITIONS
CHAPTER 82: LOCAL HIRING POLICY FOR CONSTRUCTION
CHAPTER 83: FIRST SOURCE HIRING PROGRAM
CHAPTER 84: SAN FRANCISCO RESIDENTIAL RENT ASSISTANCE PROGRAM FOR PERSONS DISQUALIFIED FROM FEDERAL RENT SUBSIDY PROGRAMS BY THE FEDERAL QUALITY HOUSING AND WORK RESPONSIBILITY ACT OF 1998 (QHWRA)
CHAPTER 85: THE HOUSING INNOVATION PROGRAM
CHAPTER 86: CHILDREN AND FAMILIES FIRST COMMISSION
CHAPTER 87: FAIR HOUSING IMPLEMENTATION ORDINANCE
CHAPTER 88: PERFORMANCE AND REVIEW ORDINANCE OF 1999
CHAPTER 89: DEPARTMENT OF CHILD SUPPORT SERVICES
CHAPTER 90: ENTERTAINMENT COMMISSION
CHAPTER 90A: PROMOTING AND SUSTAINING MUSIC AND CULTURE
CHAPTER 91: LANGUAGE ACCESS
CHAPTER 92: REAL ESTATE LOAN COUNSELING AND EDUCATION
CHAPTER 93: PREGNANCY INFORMATION DISCLOSURE AND PROTECTION ORDINANCE
CHAPTER 94: THE SAN FRANCISCO PLAZA PROGRAM
CHAPTER 94A: THE SAN FRANCISCO SHARED SPACES PROGRAM
CHAPTER 94B: ENTERTAINMENT ZONES
CHAPTER 94D: GREATER DOWNTOWN COMMUNITY BENEFIT DISTRICT MASTER PERMITTING FOR ENTERTAINMENT ACTIVATION PROGRAM
CHAPTER 95: IDENTIFICATION CARDS
CHAPTER 96: COORDINATION BETWEEN THE POLICE DEPARTMENT AND THE DEPARTMENT OF POLICE ACCOUNTABILITY
CHAPTER 96A: LAW ENFORCEMENT REPORTING REQUIREMENTS
CHAPTER 96B: POLICY MAKING MARIJUANA OFFENSES THE LOWEST LAW ENFORCEMENT PRIORITY
CHAPTER 96C: POLICE INTERROGATION OF YOUTH - JEFF ADACHI YOUTH RIGHTS ORDINANCE
CHAPTER 96D: PRESENTATION OF YOUTH CASES
CHAPTER 96E [DOMESTIC VIOLENCE DATA REPORTING]*
CHAPTER 96F: COMMUNITY POLICING PLANS
CHAPTER 96G: LIMITS ON POLICE DEPARTMENT USE AND STORAGE OF DNA PROFILES
CHAPTER 96H: LAW ENFORCEMENT EQUIPMENT POLICIES
CHAPTER 96I: POLICE DEPARTMENT POLICIES AND PROCEDURES
CHAPTER 97: HEALTHCARE IMPACT REPORTS
CHAPTER 98: THE BETTER STREETS POLICY
CHAPTER 99: PUBLIC POWER IN NEW CITY DEVELOPMENTS
CHAPTER 100: PROCEDURES GOVERNING THE IMPOSITION OF ADMINISTRATIVE FINES
CHAPTER 101: RESTRICTING THE PURCHASE, SALE, OR DISTRIBUTION OF SUGAR-SWEETENED BEVERAGES BY OR FOR THE CITY
CHAPTER 102: OUR CHILDREN, OUR FAMILIES COUNCIL
CHAPTER 103: NON-COOPERATION WITH IDENTITY-BASED REGISTRY ORDINANCE
CHAPTER 104: COLLECTION OF SEXUAL ORIENTATION AND GENDER IDENTITY DATA
CHAPTER 105: CIGARETTE LITTER ABATEMENT FEE ORDINANCE
CHAPTER 106: CITY NAVIGATION CENTERS
CHAPTER 107: CULTURAL DISTRICTS
CHAPTER 107A: AFRICAN AMERICAN ARTS AND CULTURAL DISTRICT
CHAPTER 107B: CASTRO LESBIAN, GAY, BISEXUAL, TRANSGENDER, AND QUEER (LGBTQ) CULTURAL DISTRICT
CHAPTER 107C: AMERICAN INDIAN CULTURAL DISTRICT
CHAPTER 107D: SUNSET CHINESE CULTURAL DISTRICT
CHAPTER 109: PRIORITIZING 100% AFFORDABLE HOUSING
CHAPTER 110: FORGIVABLE LOAN FOR FIRST-TIME HOMEBUYERS
CHAPTER 111: HOUSING REPORTS FOR SENIORS AND PEOPLE WITH DISABILITIES
CHAPTER 115: AUTOMATED POINT OF SALE STATION REGISTRATION AND INSPECTION ORDINANCE
CHAPTER 116: COMPATIBILITY AND PROTECTION FOR RESIDENTIAL USES AND PLACES OF ENTERTAINMENT
CHAPTER 117: COOPERATIVE LIVING OPPORTUNITIES FOR MENTAL HEALTH PROGRAM
CHAPTER 118: PLACE FOR ALL PROGRAM
CHAPTER 119: SAFE PARKING PROGRAMS
CHAPTER 120: ADMINISTRATION OF AFFORDABLE HOUSING FUNDS
CHAPTER 121: CLOSURE OF JUVENILE HALL
CHAPTER 122: CLOSURE OF COUNTY JAIL 4
CHAPTER 123: LIBRARY LAUREATE PROGRAMS
CHAPTER 123A: LIBRARY READ TO RECOVERY PROGRAM
APPENDIX: Table of Initiative Ordinances and Policy Declarations
References to Ordinances
San Francisco Business and Tax Regulations Code
BUSINESS AND TAX REGULATIONS CODE
THE SAN FRANCISCO CODES
PREFACE TO THE BUSINESS AND TAX REGULATIONS CODE
ARTICLE 1: PERMIT PROCEDURES
ARTICLE 2: LICENSE FEES
ARTICLE 3: [REPEALED]
ARTICLE 4: [RESERVED]
ARTICLE 5: ELECTRICAL MUSICAL DEVICES
ARTICLE 6: COMMON ADMINISTRATIVE PROVISIONS
ARTICLE 7: TAX ON TRANSIENT OCCUPANCY OF HOTEL ROOMS
ARTICLE 8: SUGARY DRINKS DISTRIBUTOR TAX ORDINANCE
ARTICLE 9: TAX ON OCCUPANCY OF PARKING SPACE IN PARKING STATIONS
ARTICLE 10: UTILITY USERS TAX
ARTICLE 10B: ACCESS LINE TAX
ARTICLE 11: STADIUM OPERATOR ADMISSION TAX
ARTICLE 12: BUSINESS REGISTRATION
ARTICLE 12-A: [REPEALED]
ARTICLE 12-A-1: GROSS RECEIPTS TAX ORDINANCE
ARTICLE 12-B: [REPEALED]
ARTICLE 12B-1: NEIGHBORHOOD BEAUTIFICATION AND GRAFFITI CLEAN-UP FUND TAX OPTION
ARTICLE 12-C: REAL PROPERTY TRANSFER TAX
ARTICLE 12-D: UNIFORM LOCAL SALES AND USE TAX
ARTICLE 13: CONNECTIONS TO THE POLICE DEPARTMENT TERMINAL ALARM PANEL
ARTICLE 14: TRANSPORTATION AUTHORITY
ARTICLE 15: BUSINESS IMPROVEMENT DISTRICTS PROCEDURE CODE
ARTICLE 15A: PUBLIC REALM LANDSCAPING, IMPROVEMENT AND MAINTENANCE ASSESSMENT DISTRICTS ("GREEN BENEFIT DISTRICTS")
ARTICLE 16: [REPEALED]
ARTICLE 17: [REPEALED]
ARTICLE 20: FINANCIAL INFORMATION PRIVACY ORDINANCE
ARTICLE 21: EARLY CARE AND EDUCATION COMMERCIAL RENTS TAX ORDINANCE
ARTICLE 22: PARKING STATIONS; REVENUE CONTROL EQUIPMENT
ARTICLE 23: VEHICLE REGISTRATION FEE EXPENDITURE PLAN
ARTICLE 28: HOMELESSNESS GROSS RECEIPTS TAX ORDINANCE
ARTICLE 29: VACANCY TAX ORDINANCE
ARTICLE 29A: EMPTY HOMES TAX ORDINANCE
ARTICLE 30: CANNABIS BUSINESS TAX
ARTICLE 32: TRAFFIC CONGESTION MITIGATION TAX
ARTICLE 33: OVERPAID EXECUTIVE GROSS RECEIPTS TAX
ARTICLE 36: [REPEALED]
ARTICLE 37: FAIR WAGES FOR EDUCATORS PARCEL TAX ORDINANCE
References to Ordinances
San Francisco Campaign and Governmental Conduct Code
San Francisco Environment Code
ENVIRONMENT CODE
THE SAN FRANCISCO CODES
PREFACE TO THE ENVIRONMENT CODE
CHAPTER 1: PRECAUTIONARY PRINCIPLE POLICY STATEMENT
CHAPTER 2: ENVIRONMENTALLY PREFERABLE PURCHASING ORDINANCE
CHAPTER 3: INTEGRATED PEST MANAGEMENT PROGRAM
CHAPTER 4: HEALTHY AIR AND CLEAN TRANSPORTATION PROGRAM
CHAPTER 5: RESOURCE CONSERVATION ORDINANCE
CHAPTER 7: MUNICIPAL GREEN BUILDING REQUIREMENTS*
CHAPTER 8: TROPICAL HARDWOOD AND VIRGIN REDWOOD BAN
CHAPTER 9: GREENHOUSE GAS EMISSIONS TARGETS AND DEPARTMENTAL ACTION PLANS
CHAPTER 10: TRANSPORTATION OF AGGREGATE MATERIALS
CHAPTER 11: CELL PHONE DISCLOSURE REQUIREMENTS
CHAPTER 12: URBAN FORESTRY COUNCIL
CHAPTER 13: ARSENIC-TREATED WOOD
CHAPTER 14: CONSTRUCTION AND DEMOLITION DEBRIS RECOVERY ORDINANCE*
CHAPTER 15: GREEN BUSINESS PROGRAM
CHAPTER 16: FOOD SERVICE AND PACKAGING WASTE REDUCTION ORDINANCE
CHAPTER 17: PLASTIC BAG REDUCTION ORDINANCE
CHAPTER 18: SOLAR ENERGY INCENTIVE PROGRAM
CHAPTER 19: MANDATORY RECYCLING AND COMPOSTING
CHAPTER 20: EXISTING BUILDINGS ENERGY PERFORMANCE
CHAPTER 21: CLEAN ENERGY FULL DISCLOSURE ORDINANCE
CHAPTER 22: SAFE DRUG DISPOSAL
CHAPTER 23: DRINK TAP ORDINANCE
CHAPTER 24: BOTTLED DRINKING WATER
CHAPTER 25: CLEAN CONSTRUCTION REQUIREMENTS FOR PUBLIC WORKS
CHAPTER 26: BETTER ROOF REQUIREMENTS
CHAPTER 27: ANTIBIOTIC USE IN FOOD ANIMALS
CHAPTER 28: FLAME RETARDANT CHEMICALS IN UPHOLSTERED FURNITURE AND JUVENILE PRODUCTS
CHAPTER 29: ELECTRIC VEHICLE READINESS IMPLEMENTATION*
CHAPTER 30: RENEWABLE ENERGY FOR COMMERCIAL BUILDINGS
CHAPTER 31: ELECTRIC VEHICLE AND CHARGING IN COMMERCIAL PARKING LOTS AND GARAGES*
CHAPTER 32: MANDATORY EDIBLE FOOD RECOVERY
References to Ordinances
San Francisco Fire Code
San Francisco Health Code
HEALTH CODE
THE SAN FRANCISCO CODES
PREFACE TO THE HEALTH CODE
ARTICLE 1: ANIMALS
ARTICLE 1A: ANIMAL SACRIFICE
ARTICLE 1B: PERFORMANCE OF WILD OR EXOTIC ANIMALS FOR PUBLIC ENTERTAINMENT OR AMUSEMENT
ARTICLE 1C: SALE OF ANIMALS
ARTICLE 1D: ANIMAL FUR PRODUCTS
ARTICLE 2: COMMUNICABLE DISEASES
ARTICLE 3: HOSPITALS
ARTICLE 4: DECEASED PERSONS
ARTICLE 5: PUBLIC HEALTH - GENERAL
ARTICLE 6: GARBAGE AND REFUSE
ARTICLE 7: LAUNDRIES
ARTICLE 8: FOOD AND FOOD PRODUCTS
ARTICLE 8A: CANNABIS CONSUMPTION PERMITS
ARTICLE 9: DAIRY AND MILK CODE
ARTICLE 10: MEAT AND MEAT PRODUCTS
ARTICLE 11: NUISANCES
ARTICLE 11A: BED BUG INFESTATION PREVENTION, TREATMENT, DISCLOSURE, AND REPORTING
ARTICLE 11B: HEALTHY BUILDINGS
ARTICLE 12: SANITATION - GENERAL
ARTICLE 12A: BACKFLOW PREVENTION
ARTICLE 12B: SOIL BORING AND WELL REGULATIONS
ARTICLE 12C: ALTERNATE WATER SOURCES FOR NON-POTABLE APPLICATIONS
ARTICLE 14: AMBULANCES AND ROUTINE MEDICAL TRANSPORT VEHICLES
ARTICLE 15: PUBLIC SWIMMING POOLS
ARTICLE 16: REGULATING THE USE OF 'ECONOMIC POISONS'
ARTICLE 17: DISPOSAL OF UNCLAIMED PERSONAL PROPERTY AT SAN FRANCISCO GENERAL HOSPITAL
ARTICLE 18: PROVIDING FOR ISSUANCE OF CITATIONS TO VIOLATORS
ARTICLE 19: SMOKING POLLUTION CONTROL
ARTICLE 19A: REGULATING SMOKING IN EATING ESTABLISHMENTS [SUSPENDED]
ARTICLE 19B: REGULATING SMOKING IN SHARED OFFICE WORKPLACE [SUSPENDED]
ARTICLE 19C: REGULATING SMOKING IN PUBLIC PLACES AND IN HEALTH, EDUCATIONAL AND CHILD CARE FACILITIES [SUSPENDED]
ARTICLE 19D: PROHIBITING CIGARETTE VENDING MACHINES
ARTICLE 19E: PROHIBITING SMOKING IN PLACES OF EMPLOYMENT AND CERTAIN SPORTS ARENAS [SUSPENDED]
ARTICLE 19F: PROHIBITING SMOKING IN ENCLOSED AREAS, CERTAIN UNENCLOSED AREAS, AND SPORTS STADIUMS
ARTICLE 19G: ENFORCEMENT OF SMOKING PROHIBITIONS
ARTICLE 19H: PERMITS FOR THE SALE OF TOBACCO
ARTICLE 19I: PROHIBITING SMOKING IN CITY PARK AND RECREATIONAL AREAS AND FARMERS' MARKETS
ARTICLE 19J: PROHIBITING PHARMACIES FROM SELLING TOBACCO PRODUCTS
ARTICLE 19K: PROHIBITING SALES OF TOBACCO PRODUCTS ON PROPERTY OWNED BY OR UNDER THE CONTROL OF THE CITY AND COUNTY OF SAN FRANCISCO
ARTICLE 19L: PROHIBITING SMOKING AT CERTAIN OUTDOOR EVENTS
ARTICLE 19M: DISCLOSURE TO PROSPECTIVE RESIDENTIAL TENANTS OF WHETHER A UNIT IS SMOKE FREE OR SMOKING OPTIONAL, AND INFORMING EXISTING RESIDENTIAL TENANTS WHERE SMOKING IS OPTIONAL
ARTICLE 19N: ELECTRONIC CIGARETTES - RESTRICTIONS ON SALE AND USE
ARTICLE 19O: [SMOKELESS TOBACCO - USE PROHIBITED AT ATHLETIC VENUES]
ARTICLE 19P: PROHIBITING THE SALE OF TOBACCO PRODUCTS TO PERSONS AGED 18, 19, OR 20
ARTICLE 19Q: PROHIBITING THE SALE OF FLAVORED TOBACCO PRODUCTS
ARTICLE 19R: PROHIBITING THE SALE OF ELECTRONIC CIGARETTES LACKING FOOD AND DRUG ADMINISTRATION PREMARKET APPROVAL
ARTICLE 19S: PROHIBITING THE SALE AND DISTRIBUTION OF TOBACCO PRODUCTS IN SAN FRANCISCO
ARTICLE 20: ALKYL NITRITES
ARTICLE 21: HAZARDOUS MATERIALS
ARTICLE 21A: RISK MANAGEMENT PROGRAM
ARTICLE 22: HAZARDOUS WASTE MANAGEMENT
ARTICLE 22A: ANALYZING SOILS FOR HAZARDOUS WASTE
ARTICLE 22B: CONSTRUCTION DUST CONTROL REQUIREMENTS
ARTICLE 23: VIDEO DISPLAY TERMINAL WORKER SAFETY
ARTICLE 24: CHLOROFLUOROCARBON RECOVERY AND RECYCLING
ARTICLE 25: MEDICAL WASTE GENERATOR REGISTRATION, PERMITTING, INSPECTIONS AND FEES
ARTICLE 26: COMPREHENSIVE ENVIRONMENTAL LEAD POISONING INVESTIGATION, MANAGEMENT AND ENFORCEMENT PROGRAM
ARTICLE 27: HEALTH SERVICE SYSTEM AGREEMENT
ARTICLE 28: MEDICAL CANNABIS USER AND PRIMARY CAREGIVER IDENTIFICATION CARDS
ARTICLE 29: LICENSING AND REGULATION OF MASSAGE PRACTITIONERS AND MASSAGE BUSINESSES
ARTICLE 30: REGULATION OF DIESEL BACKUP GENERATORS
ARTICLE 31: HUNTERS POINT SHIPYARD
ARTICLE 32: DISEASE PREVENTION DEMONSTRATION PROJECT
ARTICLE 33: MEDICAL CANNABIS ACT
ARTICLE 34: HEALTHY PRODUCTS, HEALTHY CHILDREN ORDINANCE
ARTICLE 35: BIOLOGICAL AGENT DETECTORS
ARTICLE 36: CHILD COUGH AND COLD MEDICINE WARNING ORDINANCE
ARTICLE 37: TRANS FAT FREE RESTAURANT PROGRAM ORDINANCE
ARTICLE 38: ENHANCED VENTILATION REQUIRED FOR URBAN INFILL SENSITIVE USE DEVELOPMENTS
ARTICLE 39: COMMERCIAL DOG WALKING
ARTICLE 40: SAFE BODY ART
ARTICLE 41: MENTAL HEALTH
ARTICLE 42: [REPEALED]
ARTICLE 43: SURPLUS MEDICATION REPOSITORY AND DISTRIBUTION
ARTICLE 45: CITY-OPERATED ADULT RESIDENTIAL FACILITY
ARTICLE 46:
ARTICLE 47: ADULT SEX VENUES
ARTICLE 48: REQUIRING RETAIL PHARMACIES TO STOCK OPIOID ANTAGONISTS AND BUPRENORPHINE
ARTICLE 49: SPECIMEN TEST COLLECTION SITES
References to Ordinances
San Francisco Municipal Elections Code
San Francisco Labor and Employment Code
San Francisco Park Code
San Francisco Planning Code
San Francisco Zoning Maps
San Francisco Police Code
POLICE CODE
THE SAN FRANCISCO CODES
PREFACE TO THE POLICE CODE
ARTICLE 1: PUBLIC NUISANCES
ARTICLE 1.1: REGULATING THE USE OF VEHICLES FOR HUMAN HABITATION
ARTICLE 1.2 DISCRIMINATION IN HOUSING AGAINST FAMILIES WITH MINOR CHILDREN
ARTICLE 1.3: TEMPORARY MORATORIUM ON RENTAL INCREASES RENT ROLLBACK BASED UPON APRIL 15, 1979, RENTAL RATES AND REFUNDING ANY RENT INCREASES
ARTICLE 1.5: DISPLAY OF LIFE AND PROPERTY CONSERVATION DECALS
ARTICLE 2: DISORDERLY CONDUCT
ARTICLE 3: GAMES OF CHANCE
ARTICLE 4: PARADES
ARTICLE 4.5: FUNERAL PROCESSION ESCORTS
ARTICLE 5: OFFENSIVE POWDERS
ARTICLE 6: FRAUD AND DECEIT
ARTICLE 7: ANIMALS AND BIRDS
ARTICLE 7.1: HORSE-DRAWN VEHICLES
ARTICLE 8: MINORS
ARTICLE 9: MISCELLANEOUS CONDUCT REGULATIONS
ARTICLE 9.5: PROHIBITING OF PROFESSIONAL STRIKEBREAKERS
ARTICLE 9.6: REGULATIONS FOR SOLICITATION FOR CHARITABLE PURPOSES
ARTICLE 10: REGULATIONS FOR ADVERTISING
ARTICLE 10.1: REGULATING EXPOSURE OF PHOTOGRAPHS, CARTOONS OR DRAWINGS ON NEWSRACKS
ARTICLE 10.2: REGULATION OF COMPUTER RENTAL BUSINESSES
ARTICLE 11: REGULATIONS FOR AMUSEMENTS
ARTICLE 11.1: COMMERCIAL DISPLAY OF DEAD HUMAN BODIES
ARTICLE 11.2: REGULATIONS FOR ADULT THEATERS AND ADULT BOOKSTORES PERMIT AND LICENSE PROVISIONS
ARTICLE 12: REGULATIONS FOR AUTOMOBILES
ARTICLE 13: MISCELLANEOUS REGULATIONS FOR PROFESSIONS AND TRADES
ARTICLE 13.1: JUNK DEALERS - PERMIT AND REGULATION
ARTICLE 13.2 BICYCLE MESSENGER BUSINESSES
ARTICLE 13.3: CAR RENTAL BUSINESSES
ARTICLE 13.4: REDUCING RENTAL-CAR BURGLARIES
ARTICLE 14: LICENSES FOR ADVERTISING
ARTICLE 15: LICENSES FOR AMUSEMENTS
ARTICLE 15.1: ENTERTAINMENT REGULATIONS PERMIT AND LICENSE PROVISIONS
ARTICLE 15.2: ENTERTAINMENT REGULATIONS FOR EXTENDED-HOURS PREMISES
ARTICLE 15.3: PROHIBITING NUDE PERFORMERS, WAITERS AND WAITRESSES
ARTICLE 15.4: ENCOUNTER STUDIOS
ARTICLE 15.5: NUDE MODELS IN PUBLIC PHOTOGRAPHY STUDIOS
ARTICLE 15.6: ESCORT SERVICES
ARTICLE 15.7: EVENT PROMOTERS
ARTICLE 16: REGULATION OF CANNABIS
ARTICLE 17: MISCELLANEOUS LICENSE REGULATIONS
ARTICLE 17.1: REGULATIONS FOR FORTUNETELLING; PERMIT AND LICENSE PROVISIONS
ARTICLE 18: SAN FRANCISCO POLICE PISTOL RANGE
ARTICLE 19: DISPOSAL OF UNCLAIMED PROPERTY
ARTICLE 20: REPRODUCING AND FURNISHING REPORTS
ARTICLE 21: BAN ON PUBLIC USE OF GAS-POWERED LANDSCAPING EQUIPMENT
ARTICLE 22: CITATIONS FOR VIOLATIONS OF CERTAIN PROVISIONS OF THE HEALTH CODE AND POLICE CODE
ARTICLE 23: REGULATIONS FOR PORT AREA*
ARTICLE 24: REGULATING STREET ARTISTS*
ARTICLE 25: REGULATIONS FOR PRIVATE PROTECTION AND SECURITY SERVICES*
ARTICLE 26: REGULATIONS FOR PUBLIC BATH HOUSES
ARTICLE 27: REGULATIONS FOR MORTGAGE MODIFICATION CONSULTANTS
ARTICLE 28: REGULATIONS FOR PAWNBROKERS PERMIT AND LICENSE PROVISIONS
ARTICLE 29: REGULATION OF NOISE
ARTICLE 30: PERMITS FOR TOW CAR DRIVERS
ARTICLE 30.1: PERMITS FOR TOW CAR FIRMS
ARTICLE 31: REGULATIONS FOR TEMPORARY HELIPORTS AND PERMIT PROVISIONS
ARTICLE 32: REGULATIONS FOR CONDUCTING BINGO GAMES
ARTICLE 32A: REGULATIONS FOR CONDUCTING POKER GAMES
ARTICLE 33: PROHIBITING DISCRIMINATION BASED ON RACE, COLOR, ANCESTRY, NATIONAL ORIGIN, PLACE OF BIRTH, SEX, AGE, RELIGION, CREED, DISABILITY, SEXUAL ORIENTATION, GENDER IDENTITY, WEIGHT, OR HEIGHT
ARTICLE 33B: PROHIBITION AGAINST DISCRIMINATION BY CLUBS OR ORGANIZATIONS WHICH ARE NOT DISTINCTLY PRIVATE
ARTICLE 33K: [EXPIRED]
ARTICLE 33L: [EXPIRED]
ARTICLE 33M: [EXPIRED]
ARTICLE 34: REGULATIONS FOR PHOTOGRAPHERS - PERMIT AND LICENSE PROVISIONS
ARTICLE 35: FIREARM STRICT LIABILITY ACT
ARTICLE 36: PROHIBITING THE CARRYING OF A FIREARM WHILE UNDER THE INFLUENCE OF AN ALCOHOLIC BEVERAGE OR DRUG, OR POSSESSION OF A FIREARM WHILE UPON PUBLIC PREMISES SELLING OR SERVING ALCOHOLIC BEVERAGES
ARTICLE 36A: [SALE, MANUFACTURE, AND DISTRIBUTION OF FIREARMS AND AMMUNITION; POSSESSION OF HANDGUNS]
ARTICLE 36B: STORAGE OF FIREARMS IN MOTOR VEHICLES
ARTICLE 36C: PROHIBITION OF FIREARMS AT PUBLIC GATHERINGS
ARTICLE 36D: GUN VIOLENCE RESTRAINING ORDERS
ARTICLE 37: POLICE EMERGENCY ALARM ORDINANCE
ARTICLE 38: PROHIBITING DISCRIMINATION ON THE BASIS OF AIDS AND ASSOCIATED CONDITIONS
ARTICLE 39: PEDICABS
ARTICLE 41: PROHIBITING THE SALE OR POSSESSION OF REPLICA HYPODERMIC NEEDLES OR SYRINGES
ARTICLE 42: SALE AND DISPLAY OF AEROSOL PAINT CONTAINERS AND MARKER PENS
ARTICLE 42A: COLOR TIRES
ARTICLE 42B: MERCURY THERMOMETERS
ARTICLE 42D: SALE AND DISPLAY OF PRODUCTS CONTAINING HYDROFLUORIC ACID
ARTICLE 43: ACCESS TO REPRODUCTIVE HEALTH CARE FACILITIES
ARTICLE 44: CLOSED CAPTIONS ACTIVATION REQUIREMENT ORDINANCE
ARTICLE 45: FIREARMS AND WEAPONS VIOLENCE PREVENTION ORDINANCE
ARTICLE 46: PROHIBITING SELF-SERVICE MERCHANDISING OF TOBACCO PRODUCTS EXCEPT IN PLACES TO WHICH MINORS HAVE NO ACCESS
ARTICLE 47: PERSONAL WATERCRAFT
ARTICLE 48: LASER POINTERS
ARTICLE 49: PROCEDURES FOR CONSIDERING ARRESTS AND CONVICTIONS AND RELATED INFORMATION IN EMPLOYMENT AND HOUSING DECISIONS
ARTICLE 50: CRIMINAL HISTORY IN ADMISSION TO POST-SECONDARY EDUCATIONAL INSTITUTIONS
ARTICLE 51: STORMWATER FLOOD RISK DISCLOSURE
ARTICLE 52: OCCUPANT'S RIGHT TO CHOOSE A COMMUNICATIONS SERVICES PROVIDER
ARTICLE 53: REGULATION OF THIRD-PARTY FOOD DELIVERY SERVICES
ARTICLE 55: ACCEPTANCE OF CASH BY BRICK-AND-MORTAR BUSINESSES
ARTICLE 56: VEHICLE SIDESHOWS
ARTICLE 58: TENDERLOIN RETAIL ESTABLISHMENT PILOT PROGRAM
References to Ordinances
San Francisco Port Code
San Francisco Public Works Code
PUBLIC WORKS CODE
THE SAN FRANCISCO CODES
PREFACE TO THE PUBLIC WORKS CODE
ARTICLE 1: GENERAL REQUIREMENTS
ARTICLE 2: PUBLIC CONTRACT PROCEDURE
ARTICLE 2.1: PERMIT FEES AND OCCUPANCY ASSESSMENTS
ARTICLE 2.3: HUNTERS POINT SHIPYARD
ARTICLE 2.4: EXCAVATION IN THE PUBLIC RIGHT-OF-WAY
ARTICLE 3: REGULATIONS IN REGARD TO WORKING CONDITIONS
ARTICLE 4: SEWERS
ARTICLE 4.1: INDUSTRIAL WASTE
ARTICLE 4.2. SEWER SYSTEM MANAGEMENT
ARTICLE 4.3: SEWERS
ARTICLE 5: STREET FLOWER MARKETS
ARTICLE 5.1: ANTI-LITTER RECEPTACLES
ARTICLE 5.2: TABLES AND CHAIRS IN PUBLIC SIDEWALK OR ROADWAY AREAS
ARTICLE 5.3: DISPLAY OF FRUITS AND VEGETABLES OR NONFOOD MERCHANDISE ON PUBLIC SIDEWALKS
ARTICLE 5.4: REGULATION OF NEWSRACKS
ARTICLE 5.5: DISTRIBUTION OF FREE SAMPLE MERCHANDISE ON PUBLIC PROPERTY
ARTICLE 5.6: POSTING OF SIGNS ON CITY-OWNED LAMP POSTS OR UTILITY POLES
ARTICLE 5.7: HANDBILL DISTRIBUTION ON PRIVATE PREMISES; DISPLAY OF BANNERS
ARTICLE 5.8: PERMIT REGULATIONS FOR MOBILE FOOD FACILITIES CONCERNING PRODUCTS FOR HUMAN CONSUMPTION
ARTICLE 5.9: PERMIT REGULATIONS FOR VENDORS
ARTICLE 6: STREET IMPROVEMENT PROCEDURE
ARTICLE 6.1: IMPROVEMENT PROCEDURE CODE
ARTICLE 7: MAINTENANCE DISTRICTS
ARTICLE 9: UNACCEPTED STREETS
ARTICLE 11: SPUR TRACKS
ARTICLE 13: ENGINEERING INSPECTION
ARTICLE 14: UNDERGROUND PIPES, WIRES AND CONDUITS
ARTICLE 15: MISCELLANEOUS
ARTICLE 16: URBAN FORESTRY ORDINANCE
ARTICLE 16.1: TREE DISPUTE RESOLUTION
ARTICLE 17: CONTROL OF DUMPS DISPOSING OF MATERIALS FROM CONSTRUCTION OR DEMOLITION
ARTICLE 18: UTILITY FACILITIES
ARTICLE 19: PUBLIC TELEPHONE BOOTHS ON PUBLIC SIDEWALKS
ARTICLE 20: PROHIBITED BICYCLE ACTIONS AND TRANSACTIONS
ARTICLE 21: RESTRICTION OF USE OF POTABLE WATER FOR SOIL COMPACTION AND DUST CONTROL ACTIVITIES
ARTICLE 22: RECLAIMED WATER USE
ARTICLE 23: GRAFFITI REMOVAL AND ABATEMENT
ARTICLE 24: SHOPPING CARTS
ARTICLE 25: PERSONAL WIRELESS SERVICE FACILITIES
ARTICLE 26*: ILLEGAL DUMPING
ARTICLE 27: SURFACE-MOUNTED FACILITIES
References to Ordinances
San Francisco Subdivision Code
San Francisco Transportation Code
Comprehensive Ordinance List
San Francisco Building Inspection Commission (BIC) Codes
AB-047 Specific Submittal Criteria for Reports, Special Inspections and Final Acceptance Testing of Smoke Control Systems
 
NO. AB-047   :
 
DATE   :
December 12, 2016 (Updated 01/01/2023 for code references.)
SUBJECT   :
Smoke Control Systems
TITLE   :
Specific Submittal Criteria for Reports, Special Inspections and Final Acceptance Testing of Smoke Control Systems.
PURPOSE   :
This Administrative Bulletin outlines the minimum requirements for smoke control systems in the City and County of San Francisco; it covers (1) design criteria, (2) required submittals and documentation. This Administrative Bulletin applies to both new and existing smoke control systems.
REFERENCES   :
Current edition of the California Building Code Section 909
Current edition of the California Fire Code Section 909
 
1.   GENERAL
   a.   Alternate Methods of Smoke Control
      1.   Equivalent/Alternate methods should be pre-approved by DBI/SFFD. See DBI Administrative Bulletin AB-005 for information regarding local equivalencies and DBI Administrative Bulletin AB-028 for information regarding pre-application or pre-addendum meetings. Examples of alternate methods are Natural Ventilation (not applicable to 909.20.3; Smoke proof enclosures), Garage CO Exhaust. Additional justification and analyses are required to show the method provides an equivalent level of life-safety to prescribed methods; typically consisting of providing documentation and supporting calculations.
2.   SMOKE CONTROL SYSTEM DESIGNERS QUALIFICATIONS
   a.   The building owner shall engage an architect, mechanical engineer and electrical engineer as architect and engineers-of-record, to prepare Smoke Control System design documents [SFBC 106A.3.4]. All design professionals shall be licensed in the State of California [CBC 202]. The architect and engineers-of-record shall be responsible for reviewing and coordinating all submittal documents, including reports and deferred submittals, for compatibility with the building design [SFBC 106A.3.4].
      If a smoke control consultant is engaged, this person shall be experienced in smoke control systems and shall be a fire protection engineer or mechanical engineer licensed in the State of California.
   b.   When peer review is required by DBI/SFFD, the reviewer shall be approved by DBI/SFFD, and engaged by the owner or owner’s agent.
3.   RESPONSIBILITIES
   a.   Project Owner
      1.   Designate Responsible Design Professionals and Smoke Control Report Author
      2.   Authorize Peer Review (where applicable)
      3.   Contract development and implementation of Special Inspection Program
      4.   Contract Air Balancer and Special Inspector(s)
      5.   Coordinate Document Submittals:
         i.   Alternate materials and methods requests
         ii.   Preliminary Smoke Control Report
         iii.   Final Smoke Control Report (including amendments)
         iv.   Special Inspection Proposal for Smoke Control
         v.   Final Special Inspection Report
      6.   Coordinate Plan Submittals
         i.   Site Plan
         ii.   Architectural Plan, including smoke barrier plan
         iii.   MEP Plans
         iv.   Fire Alarm Plans including Control Diagrams and Smoke Control Panel Layout
         v.   Sprinkler Plans
   b.   Design Professionals
      1.   Architect of Record
         i.   Architectural Design and Smoke Barrier Plans in accordance with the smoke control report.
         ii.   Must review architectural submittals by others to assure that smoke control system is coordinated into design.
         iii.   Inspect construction, and when satisfied that the design intent has been achieved, the architect shall seal, sign, and date the special inspection report in designated area.
      2.   Mechanical Engineer of Record
         i.   Mechanical Design in accordance with smoke control report and code requirements.
         ii.   Must review mechanical, fire alarm, sprinkler submittals by others to assure that smoke control system is coordinated into design.
         iii.   Inspect construction, and when satisfied that the design intent has been achieved, the mechanical engineer of record shall seal, sign, and date the special inspection report in designated area.
      3.   Electrical Engineer of Record
         i.   Electrical Design in accordance with smoke control report and code requirements.
         ii.   Must review electrical and fire alarm submittals by others to assure that smoke control system coordinated into design.
         iii.   Inspect construction, and when satisfied that the design intent has been achieved, the electrical engineer of record shall seal, sign, and date the special inspection report in designated area.
   c.   Smoke Control Report Author
      1.   Prepare Preliminary Smoke Control Report in accordance with architectural design.
      2.   Prepare Final Smoke Control Report (including amendments).
      3.   Establish smoke control system design, and pass/fail criteria; including necessary weather conditions acceptable during commissioning testing without further review.
      4.   Communicate with Peer Reviewer (where applicable), Fire Department, Department of Building Inspection during review and inspection phases.
   d.   Contractor
      1.   Provide inspection/testing access prior to concealment of ductwork, wiring, piping, etc.
      2.   Marking and identification of all smoke control components.
      3.   Pre-testing of all equipment and systems prior to special inspection.
      4.   Coordinate special inspection and AHJ testing.
   e.   Department of Building Inspection
      1.   Review Plans and Submittals.
      2.   Mandate Peer Review (when necessary).
      3.   Perform field inspections.
      4.   Review special inspection report.
      5.   Provide Certificate of Final Completion when work is completed.
      6.   Custodian of Records (microfilm).
   f.   Fire Department
      1.   Review Plans and Submittals.
      2.   Mandate peer review (when necessary).
      3.   Approval of Preliminary Smoke Control Concept and Final Smoke Control Report and Special Inspection Program.
      4.   Authorize fabrication of smoke control panel after approval.
      5.   Perform field inspections/witness testing and verify compliance with approved plans and documents.
      6.   Review of final special inspection report by Fire Plan Check.
      7.   Communication of deficiencies and required corrections with Plan Check, field inspectors, special inspectors, and design professionals.
      8.   Provide approval documentation when work is complete.
   g.   Special Inspector or Special Inspection Agencies
      1.   Develop special inspection procedure/program (written proposal).
      2.   Prepare special inspection report.
      3.   Witness test and document all devices affecting smoke control system.
      4.   Inspect and document all architectural features affecting smoke control design.
      5.   Where deficiencies are noted during a site visit prepare and post deficiency reports with the permit posted at the job site and notify the contractor and responsible design professionals of corrections required [CBC 1704.2.4].
   h.   Air Balancer
      1.   Perform all required testing with properly calibrated instruments.
      2.   Document all testing and inspection results and provide to Special Inspector(s).
4.   SUBMITTALS FOR SMOKE CONTROL SYSTEMS
   a.   General
      1.   Submit two sets of the following: all reports in booklet format (e.g. spiral bound), 8-1/2 × 11 sheets; drawings, minimum 11 × 17 sheets. One set of each will be returned when approved. Reports shall be accompanied by two sets of CD-Rs with a copy of the report in PDF format including all appendices, diagrams, and all supporting calculation files (with all supporting design scenarios and data files) “burned” onto the CDs. Each CD shall be in a slim plastic “jewel case” with a clear cover. The permit application number, report title, project name and address, CD-R files, report date, and revision number shall be clearly labeled on the CD-R.
      2.   Construction documents shall include sufficient information and detail to adequately describe the design and properly facilitate installation.
      3.   Three types of reports are required: (1) the Smoke Control Report, (2) Special Inspection Program, and (3) Special Inspection and Testing Final Report. Approval of the Smoke Control Report and Special Inspection Program are required before the Mechanical Permit is issued. Provide the (3) Final Testing Report [CBC 909.18.8.3] and Identification and Documentation [909.18.9] to DBI/SFFD at project completion.
      4.   A complete Special Inspection Program with sample reports shall be submitted with the mechanical plans to DBI/SFFD for review and approval prior to issuance of the mechanical permit. Refer to Special Inspection Program requirements section.
   b.   Smoke Control Report
      1.   A written report, titled Smoke Control Report, shall be authored by the smoke control consultant or the mechanical engineer-of-record and submitted to DBI/SFFD for review and approval. The Smoke Control Report is typically a multi-phased approval process and submitted as follows:
         i.   For site permit projects submit a preliminary Smoke Control Report with the site permit drawings. The preliminary Smoke Control Report is generally conceptual in nature, but still includes all aspects required in the final report, including AB-047 Signature Page-Attachment 1, less the specific calculations, supporting data, and diagrams. The acceptance of the preliminary Smoke Control Report does not constitute final approval by SFFD or DBI. Submit the Smoke Control Report as part of the review and approval process of the Architectural, Mechanical, and Electrical addendum drawings.
         ii.   For all projects without a site permit, submit the complete Smoke Control Report with the Architectural drawings (for reference). Submit the Smoke Control Report and Special Inspection Program with the Mechanical, and Electrical drawings, as part of the drawings’ review and approval process.
         iii.   If the Smoke Control Report is revised after approval by DBI/SFFD, the revised report shall be resubmitted with all items required and provided in the original submittal and revised plans showing applicable changes.
      2.   The Smoke Control Report shall include the following information:
         i.   Cover Page: Provide a cover page showing the facility name, address, revision number, permit application and revision numbers, date of submittal and preparer.
         ii.   Signature Page: Provide a completed signature page with final report; AB-047 Attachment 1.
         iii.   Code References: Provide reference to and include copies in appendices of all approved alternate means and methods, and pre-application agreements relating to smoke control. List all applicable codes standards including editions, approved equivalencies, and pre-application agreements for the project.
         iv.   Building Description: Provide a general narrative overview of the building and its uses. Include the building height, number of stories, basement levels, gross floor area, types of occupancies and type(s) of construction, approved variances and equivalencies. Identify the architectural features that affect smoke control design and life-safety: size of atriums, location of fire/smoke barriers, fire-safeing, engineering judgments, make-up air openings, operable windows, vents, floor and wall openings, door closers, ceiling heights, pressurized and non-pressurized stair enclosures, open stairs, shafts used as ducts, duct construction and material, exiting, horizontal exits, heights and types of surrounding structures/buildings, Elevators for Firefighters use.
         v.   Fire suppression systems: Provide a concise narrative overview of the fire suppression system(s). Identify the types of systems and areas served (zoning), major equipment, design criteria and basic operation. Identify the type, location and quantity of flammable or combustible fuel, and hazardous/toxic materials, if any.
         vi.   HVAC and ventilation systems: Provide a concise narrative overview of the HVAC systems whether or not used for smoke control. Identify the types of systems and areas served (zoning), major equipment, fire and smoke dampers type and class including link temperatures, design objectives and basic operation. Identify where fire dampers have actuating devices with increased operating temperatures (not more than 350°F) due to smoke control [CBC 717.3.3] and specify the actuating temperatures for each type of fire damper. Identify where fire/smoke dampers are not provided due to smoke control [CBC 717.2.1; 717.5.3, #1.3, #4]. Identify where fire/smoke dampers are not provided at shafts due to 22-inch sub-ducts and continuously operating exhaust fans connected to the standby power system [CBC 717.5.3, #1.1, #2.2, #2.3].
         vii.   Power supply systems: Provide a concise narrative overview of the primary and standby power sources for the smoke control systems. Include the locations of the standby power source, transfer switches, normal power transformers and switchgear, and describe the independent routing of the normal and standby power distribution systems [CBC 909.11]. Identify the type, location and quantity of flammable or combustible fuel, if any. Address the need for uninterruptible power supplies and power surge protectors [CBC 909.11.1]. Provide a table to indicate all equipment required to be connected to emergency power. Specify the required duration the Stand-by/Secondary Power supply is required to operate the Smoke Management System [909.4.6]. Note standby power is usually required for scavenger fans.
         viii.   Fire alarm, detection and control systems: Provide a concise narrative overview of the fire alarm, detection and control systems as they relate to the smoke control system. Include the building management system (BMS) where used for or interconnected to the smoke control system. BMS systems shall be listed for smoke control use. Identify the smoke control components that must be monitored for proper operation (supervised end-to-end) and the method of supervision [CBC 909.12]. Address the listing of fire detection and control systems (UL category UUKL) including the building management system where used for smoke control [CBC 909.12].
            a.   Damper supervision and control at the Firefighters Control Panel is required for all active-passive zone boundaries, e.g. corridor to residential units, group control and interlocking on fans with dampers is allowed. The minimum acceptable supervision and control required will indicate proper damper operation and fault condition for smoke control operation, i.e. open and closed. These dampers shall be included in the UUKL Self-Test and fail-safe in the closed position [CBC 909].
            b.   Fan supervision and control at the Firefighters Smoke Control Panel is required for all fans used in the smoke control system [CBC 909.16]. Each fan and damper shall have a separate annunciator lights and controls, unless otherwise approved. Power (amperage and voltage) shall be supervised at the downstream side of the electrical disconnects [CBC 909.12] and a positive means of verifying airflow shall be provided (pressure switch/airflow sensor) [NFPA 92 6.4.8.2] at each fan and indicated on the Firefighters Control Panel as a fault condition if failure occurs. Supervision and control of additional fans shall be required in cases where an alternate/equivalent method is approved, e.g. where garage CO exhaust is utilized for smoke control, and use of supply fans are necessary for adequate smoke exhausting.
         ix.   Firefighters Control Panel. Include a narrative description of the Firefighters Control panel. Refer to the Fire Alarm Plan submittal section for additional information.
         x.   Smoke Control/Management Systems. Provide a concise conceptual narrative overview of the smoke control/management systems: concepts, approaches, and design objectives, types of systems, zoning, major equipment, analysis methods, and basic operation and activation sequences.
         xi.   As applicable provide a detailed description of each smoke control zone including: occupancy; fire suppression and fire alarm systems, including specific design criteria required by the smoke control system; construction type, ratings and leakage values; door and window types, ratings, leakage values, and closing methods; operable and fixed exterior openings; expected fire size/loads, combustible materials [CFC]; means of egress; method(s) of smoke control; analyses methods, with referenced equations for hand calculations, name and version of software; design scenarios addressed, including specific weather data used for each scenario; summary of results including but not limited to tenability, timed egress, i.e. ASET vs. RESET; sprinkler type and activation times; activation methods.
         xii.   Provide small-scale drawings, 11 × 17 minimum, showing the location of all smoke zones, including passive smoke zones; include the drawings as PDF files on the required CD-R.
         xiii.   Provide rational analyses of the design; address the stack effect, temperature effect of the fire, wind, HVAC interactions, climate and minimum duration of operation [CBC 909.4.4, 909.4.5, 909.10].
      3.   For smoke control systems using the passive method, identify the total leakage area for typical smoke barriers [CBC 909.5.1].
      4.   Address the probable temperatures to which fans, dampers and ducts may be exposed in a fire [CBC 909.10].
      5.   Identify smoke zone openings which must be open or closed for proper operation, such as doors, windows, dampers and louvers; identify smoke zone openings that are supervised in the open and/or closed positions.
      6.   Address the piston effect of elevators. Additionally, for single car elevator shaft provide calculations to show the smoke control system is not overcome by the piston effect.
      7.   Design Fundamentals; Where applicable the following Guidelines shall apply.
         i.   Design Fire:
            a.   A design fire engineering analysis shall be provided in the smoke control report [909.9]. Address the fuel characteristics (e.g. toxicity, particulate yield, and growth rate), fuel spacing and configurations (radiant heat), heat-release assumptions (HRR), and sprinkler effectiveness assumptions. Justify all assumptions and performance-based approaches. Identify the computer program(s) and version(s) used, if any. Include calculations and an input and output summary for each computer analysis design case.
            b.   Specify the maximum ceiling jet temperatures and time lag expected before sprinkler activation. Provide supporting calculations.
         ii.   Pressurization Method:
            a.   Stairway pressurization systems: Comply with CBC 909.20 to 909.20.4-6 and NFPA 92 4.6 to 4.6.4.2. Use of vestibule transfer grills is not acceptable except for pressurization of large stairway transfer passageways.
            b.   Pressurization calculations may be based on maximum leakage values provided in the CBC [CBC 909.5.] However, architectural specifications for construction leakage may be used if documented in report.
            c.   A minimum Pressure differential of 0.05-water gauge is required across all smoke barriers in fully sprinklered buildings. Un-sprinklered buildings shall comply with CBC 909.6.1 for pressure differentials. [CBC 909.6, 909.6.1].
            d.   Computer calculations shall be provided for all buildings utilizing a multizone model program that is valid for the application, e.g. CONTAM. State all variables used/required in the calculations and additional modifiers are available and used in the calculations, e.g. Wind Tunnel data, provide information in the report. Hand calculations may be provided and/or required to verify computer calculations.
            e.   Base calculations input data on 1 percent wind speeds and dry bulb temperatures of 99.6 and 0.4 percent (NFPA 92A, A.4.4.1). Include prevailing winds, summer and winter, and all other wind directions considered critical to demonstrate wind effects. Current wind data shall be obtained from a nationally recognized authority, e.g. ASHRAE, and included in the report. Use of site specific wind data is recommended.
            f.   All exterior openings and non-smoke management fans in smoke control zones and sub-zones that are operable in smoke control mode shall be included in the analysis in their normal position, e.g. windows, doors, scavenger fans, z-ducts and vents (NFPA 92A, 4.6.1, and 7.1.1.2).
            g.   For smoke control systems using the pressurization method, identify the minimum and maximum pressure differences across smoke zone boundaries (smoke barriers) separating smoke zones [CBC 909.6.1]. Include calculations for each smoke zone where appropriate. Analyses shall include all openings fixed in open position, and within reason openings expected to be opened, e.g. Z-ducts, operable windows and/or doors [NFPA 92 72.2].
            h.   Provide smoke detectors at each floor level entrance to smoke proof enclosure [CBC 909.20.6 and 907.3.1.]. Note: This requirement is satisfied if full area smoke detection is provided throughout the room or corridor accessing the smoke proof enclosure vestibule.
            i.   Provide full area smoke detection in residential corridors to activate the corridor exhaust fans. Activation of the smoke control system by full area smoke detection within residential corridors may be used in lieu of activation by the zoned fire sprinkler system. An application for equivalency per SFDBI Administrative Bulletin AB-005 will not be required for compliance with CBC 909.12.3 for residential corridors.
            j.   Comply with CBC 909.20.7, to provide protection of equipment, control and power wiring, and ductwork.
            k.   Provide pressurization of Fire Service Access Elevator only if the smoke control system is designed under the Current Edition of the CBC/SFBC.
         iii.   Exhaust Method: Typically used in large volume areas, e.g. atriums [CBC 909.8].
            a.   Where space is a simple geometry (no obstructions, simple air supply/makeup air and exhaust, symmetrical square construction) exhaust of smoke may be done using NFPA 92 algebraic calculations.
            b.   In spaces with complicated geometries and/or tenability is used as design criteria, CFD analysis may be required. A complicated geometry is where airflow is obstructed, multiple air supplies, or construction is asymmetrical.
            c.   All exterior openings and non-smoke management fans in smoke control zones and sub-zones that are operable in smoke control mode shall be included in the analysis, e.g. windows, doors, scavenger fans and vents.
         iv.   Natural Ventilation:
            a.   Designs that utilize natural ventilation (not applicable to 909.20.3; Smoke proof enclosures) in whole or part of the smoke management system will require CFD or physical (scale) model analysis.
            b.   The affect of outdoor wind, temperature, design fire size, and the surrounding structures are especially important in the design of natural ventilation smoke control. Multiple design scenarios that reflect a complete range of operating conditions are required to demonstrate the validity of the smoke control systems’ function.
            c.   Wind speeds shall range from zero to the 1 percent annual extreme. Include prevailing winds, summer and winter, and a minimum of 4 other wind directions considered critical to demonstrate wind affect at the required wind speeds. Current wind data shall be obtained from a nationally recognized authority, e.g. ASHRAE, and included in the report.
            d.   Ambient temperature used in calculations shall range from low to high annual extremes, dry bulb temperatures of 99.6 and 0.4 percent, as reported by the most current data obtained from a nationally recognized authority, e.g. ASHRAE.
            e.   For verification of commissioning and testing data provide design calculations for the temperature(s) and wind condition(s) experienced during the testing.
            f.   All openings in smoke control zones that are operable shall be included in the analysis, e.g. windows, doors, and vents. Separate design scenarios for each zone with open and openings closed shall be included.
         v.   Airflow Method: Typically used in tunnels or spaces connected to large volume spaces to manage the flow of smoke from fires.
            a.   Simple geometrical spaces (no obstructions, simple air supply and exhaust, symmetrical smooth construction) the critical air velocity calculation required to prevent the backflow of smoke may be per NFPA 92, section 5.10, Opposed Airflow and CBC, Section 909.7.
            b.   In spaces with complicated geometry (rough, asymmetric construction) and/or where/when tenability is used as design criteria, CFD analysis is required. A complicated geometry is where airflow is obstructed, multiple air supplies, or construction is asymmetrical.
            c.   All openings in smoke control zones that are operable shall be included in the analysis, e.g. windows, doors, and vents. Separate design scenarios for each zone with open and openings closed shall be included.
         vi.   Tenability: Tenability criteria shall be established based on approved documented studies. Items to be included, but not limited to, determining tenability criteria are the following: temperature and humidity, visibility (KS3, light reflecting), toxicity assessment of combustion products and FED.
         vii.   Egress Analysis: Timed egress analyses shall be based on CBC 909.4.6 (where duration of system is less than 20-minutes) based on documented methods as provided in the listed references.
Calculation of Available Safe Egress Time (ASET) and Required Safe Egress Time (RSET) with a minimum safety factor of (1.5). ASET and RSET shall be calculated in phases/time segments: ignition-detection, detection-alarm, alarm-perception, perception-interpretation, interpretation-action, action-movement, and tenability limit only for ASET. Occupancy loads shall be determined by the CBC or actual occupant load, whichever is greater. Consideration shall be made for handicapped and disabled occupants by reduction of travel speeds and flow rates. Lastly, duration of the smoke management system operation shall be the code required minimum or the maximum RSET, whichever is greater.
   c.   Architectural Drawings
      1.   Include a compliance statement stamped and wet signed by the architect-of-record which states:
         “I have reviewed the Smoke Control Report and confirm the smoke management/control system elements shown on the drawings under my responsible charge comply with the Smoke Control Report by (REPORT AUTHOR) and (DATE OF REPORT).”
      2.   As part of the architectural drawings provide smoke barrier drawings showing the location of all smoke zones: delineate each zone as passive or active and provide a zone designation for each active zone. Additionally, show occupancies of each smoke zone and all openings required, e.g. doors required to open for make-up air. The zones and designations used in the architectural drawings shall correspond to zones and designations used in the smoke control report.
      3.   Provide sufficient detail in the drawings to support engineering calculations, e.g. leakage values for walls, ceilings, and doors; locations and heights of surrounding buildings; sizes and locations of make-up air openings; and smoke-barrier wall construction details.
   d.   Mechanical Permit Drawings
      1.   In addition to the information that is typically provided in mechanical drawings, provide the following information in the drawings:
         i.   Include a compliance statement stamped and wet signed by the mechanical engineer-of-record which states: “I have reviewed the Smoke Control Report and confirm the smoke management/control system elements shown on the drawings under my responsible charge comply with the Smoke Control Report by (REPORT AUTHOR) and (DATE OF REPORT).”
         ii.   Submit approved architectural plans that show the location of all smoke zones, including passive smoke zones.
         iii.   Provide a schematic riser diagram of the smoke control/management systems.
         iv.   Provide a narrative summary and sequence of operations of the smoke control/management system operation.
         v.   Identify the major mechanical components used for smoke control in appropriate schedules. Include fans, drivers, variable frequency drives (VFDs) and their locations, and louver and damper operators. Indicate the minimum service factor for fan motors (1.15) and the minimum number of fan belts for belt-driven fans, and temperature rating of fans and ducts [CBC 909.10].
         vi.   Identify the ducts and shafts used for smoke control in the schematic riser diagrams and plan drawings. Indicate the minimum test pressure for ducts and shafts used for smoke control (1.5 times the maximum design pressure) [CBC 909.10.2]. All shafts shall be sheet metal lined, unless an alternate method is approved [CMC 602].
         vii.   For smoke control systems with variable frequency drives (VFDs), locate the VFDs outside the smoke zone they serve. Alternatively, protect VFDs within the smoke zone they serve from smoke and heat so they are capable of continued operation after detection of fire for at least 20 minutes or the time set by the required safe exiting time (1.5 times RSET), whichever is less [CBC 909.4.6.] VFDs shall not serve more than one end device unless listed for smoke control service. Specify the “fail-safe” VFD operation mode and speed.
         viii.   For air-moving systems greater than 2,000 cfm, identify where automatic shutoffs are not provided due to smoke control [CMC 609].
      2.   Prerequisites for a mechanical permit issuance: Approved architectural plans, approved Smoke Control Report, and an approved Special Inspection Program.
   e.   Electrical Permit Drawings
      1.   In addition to the information that is typically provided in electrical drawings, include the following information in the drawings:
         i.   Include a compliance statement stamped and wet signed by the electrical engineer-of-record which states:
         “I have reviewed the Smoke Control Report and confirm the smoke management/control system elements shown on the drawings under my responsible charge comply with the Smoke Control Report by (REPORT AUTHOR) and (DATE OF REPORT).”
         ii.   Identify the major electrical components used for smoke control, including standby (or emergency) power source, transfer switches, and control system(s).
         iii.   Provide load calculations for the standby/emergency power source.
         iv.   Show the layout of the standby generator room (or other secondary power source). The standby generator and its transfer switches shall be in a separate room from the normal power transformers and switchgear [CBC 909.11, 909.11.1].
         v.   Show the routing and fire rating of the normal and standby power distribution systems. The normal and standby power systems shall be routed independently [CBC 909.11].
         vi.   Show the locations of the fire alarm control panel (FACP), firefighters’ smoke control panel (FSCP) and fire alarm annunciator(s).
         vii.   Provide a 1-line diagram showing feeder conductor sizes, overcurrent protection sizes, ampacity calculations, and the connected loads on each feeder supplied by the standby (or emergency) power source [CEC 215.5, 310, 700.5, 701.4, 701.6].
         viii.   For high-rise buildings, show the layout of the Fire Command Center (Central Control Station). See CBC 403.4.6, and 911, for required equipment and furnishings.
         ix.   For buildings with passive smoke zones, connect the motor operators for smoke dampers to the building power panel and emergency/standby power – not the tenant space power panels.
   f.   Sprinkler System Permit Drawings
      1.   Sprinkler system submittals shall be in accordance with SFFD Administrative Bulletin AB 2.04, Fire Sprinkler Submittals.
      2.   In addition to the information that is typically provided in sprinkler system permit drawings, include the following information in the drawings:
         i.   The mechanical engineer-of-record shall review the sprinkler system permit documents for conformance with the smoke control report, prior to submittal to DBI/SFFD and shall so indicate by stamping “Reviewed for Smoke Control Design Compliance, (REPORT AUTHOR) and (DATE OF REPORT)” and signing on each drawing and document.
         ii.   For atriums, provide separate sprinkler zones for the atrium and non-atrium spaces [CBC 909.12.3].
         iii.   For malls, provide separate sprinkler zones for mall and tenant spaces [CBC 402.5, 909.12.3].
         iv.   High-rise buildings with multiple active zones: each zone shall have 2 supplies.
   g.   Fire Alarm System Permit Drawings
      1.   Fire alarm submittals shall be in accordance with SFFD Administrative Bulletin AB 2.01, Fire Alarm Submittals.
      2.   In addition to the information that is typically provided in fire alarm system permit drawings, include the following information in the drawings:
         i.   The mechanical engineer-of-record and electrical engineer-of-record shall review the sprinkler system permit documents for conformance with the smoke control report, prior to submittal to DBI/SFFD and each engineer shall so indicate by stamping “Reviewed for Smoke Control Design Compliance, (REPORT AUTHOR) and (DATE OF REPORT)” and signing on each drawing and document.
         ii.   (REPORT AUTHOR) and (DATE OF REPORT)” and signing on each drawing and document.
         iii.   Provide a detailed fire alarm/smoke control matrix.
            a.   Show every fire alarm/smoke control system input in a column on the left. Include every initiating device by address. Inputs may be combined with prior approval. Include manual operation of control switches for fans and dampers where the switch controls multiple outputs.
            b.   Show every fire alarm/smoke control system output in a row across the top. Include every notification appliance by zone, every fan and damper (or group of dampers) by identifier, every monitored device by identifier and every other event that must occur for proper operation of the smoke control system. Control may be combined with prior approval.
            c.   Show automatic fan shutoffs per CMC 609 where required or provided.
            d.   Show supervised conditions for required smoke control components such as fan power disconnect, pressure differentials switches, switches, fans not full speed, and doors/windows/dampers open or closed.
            e.   Alarm, supervisory and trouble signals shall be transmitted to an approved supervising station in accordance with NFPA 72 [CBC 907.6.5].
         iv.   Provide a full scale color drawing of the Firefighters Smoke Control Panel (FSCP) for review and approval prior to fabrication [CBC 909.2].
            a.   Show individual control switches for fans and dampers or multiple dampers with identical actions, and automatic closing/opening doors required for smoke control [909.16.2].
            b.   The FSCP shall show status indicators for all smoke control equipment by pilot lamp-type indicators as follows [CBC 909.16.1]:
               •   GREEN: Fans, dampers and other operating equipment are in their ON or OPEN status. Provide a green light to indicate Smoke Control Mode and another for Manual Mode.
               •   RED: Fans, dampers and other operating equipment are in their OFF or CLOSED status.
               •   YELLOW: Fans, dampers and other operating equipment are in a fault status.
            Add two pilot lamp-type indicators at right top of FSCP to indicate panel is in smoke control mode: green-normal and red-smoke control mode.
            c.   Provide a legend or matrix either on the FSCP or separately mounted adjacent to the FSCP showing the configuration of fans, dampers and doors in normal status mode and smoke control status mode.
            d.   Alternate designs of the firefighters’ smoke control panel may be approved on a case-by-case basis by SFFD.
            e.   Provide lamp-type indicator for supply airduct smoke detectors adjacent to fan control switch. E.g., garage and/or stairway fan.
         v.   Include a reference copy of the approved mechanical plans.
      3.   Smoke control systems shall have an automatic weekly self-test feature. The self-test feature shall automatically command activation of each associated function(s). An audible and visual trouble signal shall be annunciated at the FSCP identifying any function that fails to operate within the required time period [CBC 909.12, 907; UL 864].
   h.   Smoke Control Systems Designed Per the 1995, 2010 CBC/SFBC or Later.
      Note: Due to the change in model code from the Uniform Building Code (UBC) to the International Building Code (IBC), there was no 2004 CBC/SFBC.
      1.   For existing smoke control systems designed per the 1995 Edition of the CBC/SFBC or later Edition of the CBC/SFBC, comply with the requirements of Section 5 for the modified portions of the system except as revised in this section.
      2.   Where modifications to existing smoke control systems are made and original approved reports are not available, provide a new Smoke Control Report, Special Inspection Program and Final Testing Report.
      3.   Where modifications to existing smoke control systems are minor, DBI/SFFD may waive requirements for new reports or amendments to the original approved reports on a case-by-case basis. Minor modifications do not include new FSDs, smoke barriers/walls, a new Fire Alarm system, changes in use/occupancy, replacement of equipment (not in-kind), or like changes to the building and its systems.
      4.   Where work is done to a building with a smoke control system provide on plans a narrative of the smoke control/management system(s) operation and a matrix of fire/smoke damper operations for normal and smoke control modes of the smoke management system(s).
      5.   Where building renovations do not affect the design or operation of existing smoke control systems, provide the following non-infringement statement on the permit drawings:
         “I have read the Smoke Control Report and confirm the building renovations on the drawings under my responsible charge do not affect the design or operation of existing smoke control systems.”
      The non-infringement statement shall be signed by the architect and engineers-of-record (mechanical and electrical).
   i.   Smoke Control Systems Designed Per the 1992 CBC/SFBC or Earlier
      1.   For smoke control systems designed per the 1992 CBC/SFBC or earlier, comply with the requirements of this section.
      2.   Where building renovations affect the design or operation of existing smoke control systems, provide a smoke control narrative on the permit drawings that describes the building renovations and modifications to the existing smoke control systems.
      3.   Where work is done to a building with a smoke control system provide on plans a narrative of the smoke control/management system(s) operation and a matrix of fire/smoke damper operations for normal and smoke control modes of the smoke management system(s).
      4.   Where building renovations do not affect the design or operation of existing smoke control systems, provide the following non-infringement statement on the permit drawings:
         “The building renovations shown on the drawings under my responsible charge do not affect the design or operation of existing smoke control systems.”
      The non-infringement statement shall be signed by the architect and engineers-of-record.
5.   SPECIAL INSPECTION REQUIREMENTS FOR SMOKE CONTROL SYSTEMS
   a.   Special Inspector
      1.   CBC, Section 909 requires a special inspector to perform inspection and acceptance testing of smoke control systems.
      2.   The special inspector is responsible for verifying that the smoke control system is installed in accordance with the requirements of CBC, Section 909, and that the system achieves the performance defined in the Smoke Control Report.
   b.   Inspection and Test Process
      1.   Two inspection and testing processes are required for smoke control systems:
         i.   Special inspection/testing by a special inspector, and
         ii.   When the special inspector is satisfied that the smoke control system is properly installed and functioning per design, DBI/SFFD inspectors witness final acceptance testing.
   c.   Submittals
      1.   Two submittals are required to document special inspection:
         i.   A written inspection and test program, and
         ii.   A report describing the inspection and testing performed (as required by CBC, Section 909.18.8, AB-046).
   d.   New and Modified Smoke Control Systems
      1.   Inspection, testing and submittal requirements for projects involving modifications to existing smoke control systems are the same as for projects involving new smoke control systems. While new systems require 100 percent of the smoke control system to be tested, the extent of testing required for modifications to existing systems shall be approved by DBI/SFFD.
6.   SPECIAL INSPECTION QUALIFICATIONS
   a.   Special Inspector
      1.   The special inspector shall be employed by the owner, owner’s agent, architect or engineers-of-record but not the contractor or any other person responsible for the work [SFBC 106A.3.5].
      2.   The special inspector shall be a qualified person who shall demonstrate competence, to the satisfaction of DBI and SFFD, for the inspection and testing of smoke control systems.
      3.   The special inspector may be the smoke control system designer, if qualified per 7.1.2.
   b.   Testing Agencies
      1.   Testing agencies shall be engaged by the owner or owner’s agent; “The special inspector shall be employed by the owner, the engineer or architect of record, or an agent of the owner, but not the contractor or any other person responsible for the work” [SFBC 106A.3.5].
      2.   Testing agencies that measure HVAC performance (TAB agencies) shall be certified by the Associated Air Balance Council (AABC) or the National Environmental Balancing Bureau (NEBB).
7.   SPECIAL INSPECTION SUBMITTALS FOR SMOKE CONTROL SYSTEMS
   a.   Special Inspection Program
      1.   General
         i.   A written Special Inspection Program shall be submitted to DBI/SFFD for review and approval [SFBC 106A.3.5].
         ii.   The Special Inspection Program shall be prepared by the architect, mechanical engineer-of-record or the author of the Smoke Control Report. The Program may also be prepared by the special inspector if duly qualified. [CBC 909.18.8.2]
            •   Include the special inspector’s resume with the special inspection program.
         iii.   The Special Inspection Program shall be submitted with the complete Smoke Control Report for review with the Mechanical and Electrical drawings. The issuance of the mechanical and electrical permit is dependent on approval of the submittals of the Smoke Control Report and Special Inspection Program.
      2.   The Special Inspection Program shall include at least the following information:
         i.   Provide a cover page showing the facility name, address, revision number, date of submittal and preparer.
         ii.   Provide a signature page per the attached form; AB-047 Attachment 1 signature page.
         iii.   Identify the components and systems that must be inspected to demonstrate proper installation.
         iv.   Samples of Inspection Reports and time limits for submission of reports.
         v.   Provide an overview of test methods and test approach.
            a.   When leakage testing of residential smoke barriers is to be performed, the Special Inspection Program shall define the number or percentage of units (minimum of 10% of the units or 1 per floor, whichever is greater) to be tested. Include the method of testing, percentage of smoke barriers to be tested and pass/fail criteria.
            b.   If cold/hot smoke visualization testing is required by SFFD, this must be specifically addressed in the Program description. Provide testing details and methods proposed.
      3.   Two hard-copies of the Program shall be submitted in booklet form to DBI for logging-in. One copy will be returned when approved. The Program documents shall be accompanied by two CD-Rs, each with a copy of the Program “burned” onto the CD-R in PDF format. Each CD-R shall be in a slim plastic “jewel case” with a clear cover. The permit application number, project name and address, report title, date and revision number shall be clearly marked on the CD-R.
   b.   Documentation to Support Final Inspection by DBI/SFFD
      1.   When the special inspector determines that the smoke control system is complete and operating properly, then he/she shall write a letter documenting its status. The letter shall be provided to the DBI/SFFD inspectors. The letter is required prior to DBI/SFFD starting their final inspection.
      2.   Satisfactory completion of final inspection of the smoke control system by DBI/SFD inspectors is a prerequisite for TCO.
   c.   Final Report for Special Inspection and Testing (Commissioning Report for CFO)
      1.   A complete Smoke Control System Commissioning Report meeting the requirements of CBC 909.18.8.3 shall be submitted to DBI/SFFD for review and approval.
      2.   Acceptance of the Report by DBI/SFFD is a prerequisite for TOC.
      3.   Include completed attachments 2 and 3; Special Inspection and Testing Checklist, Final Report; for each smoke control system.
      4.   Two hard-copies of the Report shall be submitted to DBI in booklet format for logging-in. The Report copies shall be accompanied by two CD-Rs, each with a copy of the Report “burned” onto the CD-R in pdf format. Each CD-R shall be in a slim plastic “jewel case” with a clear cover. The permit application number, report title, project name and address, date and revision number shall be clearly marked on the CD-R.
      5.   A copy of the Report shall be provided to the SFFD inspector.
      6.   A copy of the Report shall be maintained in the fire control room.
8.   INSPECTION AND TESTING OF SMOKE CONTROL SYSTEMS
   a.   General
      1.   This section provides specific requirements and clarifications for the inspection and testing of new smoke control systems. These requirements are in addition to those specified in CBC, Section 909.
      2.   Projects involving modifications to existing smoke control systems shall employ only those requirements listed below applicable to the project.
   b.   SF Inspection and Testing Requirements
      1.   Special Inspector shall Inspect and test to the following approved documents:
         i.   Smoke Control Report;
         ii.   Fire Alarm system shop drawings with the detailed smoke control sequence of operations matrix and the approved Firefighter’s Control Panel configuration;
         iii.   Architectural plans, with emphasis on smoke barrier plans;
         iv.   Fire Sprinkler plans, with focus on zoning and special design criteria required for smoke control design;
         v.   Mechanical plans;
         vi.   And Electrical plans.
      2.   Witness duct and shaft leakage testing. The test method shall be in accordance with SMACNA, HVAC Systems Testing, Adjusting and Balancing, Second Edition, 1993. Leakage testing shall be performed prior to the installation of dampers, but with all laterals installed. The test pressure and allowable leakage shall be in accordance with CBC, 909.10.2.
         Testing shall be performed during erection of ductwork and prior to concealment.
      3.   Witness leakage testing of the number of dwelling units defined in the Special Inspection Program. Leakage testing shall be accomplished using a calibrated door-fan test rig. Test pressure shall be approximately 0.05 in. WG or greater as determined by design. Measured leakage shall be compared to compartment leakage determined by calculation using allowable barrier leakage area ratios in CBC, 909.5 or architectural specification as applicable.
      4.   Witness airflow testing.
      5.   Visually inspect representative portions of the installed perimeter fire-safing to verify installation per its Listing and/or engineering judgment.
      6.   Visually inspect the Firefighter’s Control Panel (FFCP) and verify:
         i.   The configuration is consistent with approved fire alarm drawings;
         ii.   The panel is representative of the building smoke control system;
         iii.   Indicator lights meet San Francisco requirements:
            •   Green light: Fan ON or Damper OPEN;
            •   Red light: Fan OFF or Damper CLOSED;
            •   Yellow/Amber light: Damper/Fan FAULT or Loss of Power;
         iv.   Verify that loss-of-power or airflow to each smoke control fan causes an immediate illumination of the associated FAULT light on the FSCP.
         v.   Verify that fire alarm control/monitor modules are within 3 feet of HVAC equipment used for smoke control OR that the wiring between is supervised.
         vi.   Verify that the blades on each FSD are monitored. Grouped FSDs with independent motors and jackshafts require the blades of each FSD to be monitored.
         vii.   Verify that all VFD control panels are removed or the HOA on each VFD is password-protected.
      7.   The condition of the building shall be as follows during testing:
         i.   Pressure testing shall be performed with:
            a.   Permanent power to the building and all smoke control equipment;
            b.   Windows and exterior doors CLOSED;
            c.   Sub-ducted exhaust systems (toilet, kitchen and dryer) ON at fire-event speeds;
            d.   Dampers and fans that shut down during a fire event are CLOSED/OFF.
         ii.   Proper operation of the smoke control system under standby power shall be verified (as a minimum) by:
            •   Verifying that current and voltage under normal and standby power are equivalent
         iii.   Current switches shall be adjusted after the building has been verified to be properly balanced. Adjustment shall be verified to indicate a no-belt condition, where appropriate.
      8.   The weekly self-test shall be observed and the following verified:
         i.   A written report is produced. The report must clearly indicate a “start” of the test and an “end.” The report must clearly indicate any failures, but need not specify the component that fails.
         ii.   The test shall cycle those components required for proper operation of the smoke control system as identified in the smoke control report.
         iii.   Any failure during the self-test shall place a “TROUBLE” on the fire alarm control panel and notify Central Station.
         iv.   Any alarm shall interrupt the self-test.
      9.   Special Inspector shall verify that documentation and equipment labels are in order.
         i.   Verify that all fans and dampers used for smoke control are field labeled consistent with the control drawings (approved fire alarm drawings) and the Firefighter’s Control Panel (FFCP). Fan labels shall be red phenolic with 1 white lettering. Where the fan and the local disconnect/control panel are not immediately adjacent, both shall be labeled.
         ii.   Verify that the following are available (or will be available) in the fire control room:
            a.   As-built fire alarm (control) shop drawings;
            b.   Smoke control event matrix (typically in the approved fire alarm shop drawings);
            c.   The approved smoke control report;
            d.   Weekly self-test reports;
            e.   Final Smoke Control Special Inspection report.
9.   REFERENCED PUBLICATIONS
   These documents are considered part of this Administrative Bulletin.
      a.   Current edition of the California Building Code (CBC) / San Francisco Building Code (SFBC)
      b.   Current edition of the California Fire Code (CFC) / San Francisco Fire Code (SFFC)
      c.   Current edition of the California Mechanical Code (CMC) / San Francisco Mechanical Code (SFMC).
      d.   Current edition of the California Electrical Code (CEC) / San Francisco Electrical Code (SFEC).
      e.   NFPA 92 Standard for Smoke-Control Systems
         Guide to the 2006 IBC Smoke-control Provisions, Dr. John H. Klote and Douglas H. Evans, P.E., 2006 International Building Code.
         ASHRAE Guideline 5-1994, Commissioning Smoke Management Systems.
         SMACNA, HVAC Air Duct Leakage Test Manual, 2nd Edition, 2012.
Signed by:
 
Tom C. Hui, S.E., C.B.O.   12/15/2016
Daniel DeCossio   
Director
Fire Marshal
Department of Building Inspection
San Francisco Fire Department
 
Approved by the Building Inspection Commission on May 18, 2011 & Revision August 17, 2016.
Attachment 1: Signature Page
Attachment 2: Special Inspection and Testing Summary Checklist
Attachment 3: Special Inspection and Final Report