1003A.1 Clearances. The clearance between the door and the frame and between meeting edges of doors swinging in pairs shall not exceed 1/8 inch (3.2 mm). The clearance between the door and the floor with either flush or raised sill shall be not more than 3/4 inch (19.1 mm).
1003A.2 Door assemblies. Excluding main entry doors, all exterior swinging doors, and swinging interior and exterior entry doors, including assemblies and related hardware, which are directly accessible from the ground level or by stairs or by ramp, or from roof areas, or parking lot, or garage areas, shall meet the requirements of Grade 20 of ANSI/ASTM F476, Standard Test Methods for Security of Swinging Door Assemblies.
All such doors shall be self-closing continuously locked, and openable from the interior with no special effort or knowledge or key. Where electrically operated locks are used, they must be self-latching and locking and shall have manual release capability from the interior requiring no special effort or knowledge or key.
1003A.2.1 Main entrance. All main entry doors, including electrically operated main entry doors, shall be provided with a primary locking device. “Main entry doors” shall be defined as exterior doors leading directly into the lobby, registration areas or employee entrances.
1003A.2.2 Viewer. Each door shall be provided with a minimum 135-degree viewer which does not have sighting capability when viewed from the outside. Mounting height shall not exceed 58 inches (1473 mm).
1003A.3 Fire-rated door assemblies. Fire-rated door assemblies shall meet the requirements of Grade 20, ANSI/ASTM F476.
1003A.4 Glazing. All glazing within 40 inches (1016 mm) of any locking mechanism of exterior and interior dwelling unit doors shall be of safety glass or burglar-resistant glazing. This requirement shall not exempt the swinging door assembly standards of Grade 20 of ANSI/ ASTM F476.
1003A.5 Metal gates. Metal gates shall conform to the following:
1. Latch bolt protected by a security plate.
2. Hinges, bolts, screws shall be nonremovable.
3. Areas within 40 inches (1016 mm) of latch mechanism protected by mesh screen or approved equal.
4. Interior release mechanism protected with cover.
5. For electrically operated locks, see Section 1003A.2.
1003A.6 Sliding glass doors. Sliding glass door assemblies shall be so designed that the door cannot be lifted from the track when the door is in a locked position.
In addition to the primary locking device, all sliding glass doors shall have an auxiliary locking device permanently mounted and not accessible from the exterior of the building but easily accessible from the interior.
1003A.7 Sliding glass windows. Sliding glass window assemblies shall be so designed that the moving panel cannot be lifted from the track while in a closed position.
1003A.8 Parking areas. Parking space numbering shall not correspond to the guest room or dwelling unit number.
Exterior parking areas and access thereto shall be provided with a minimum of 1/2 foot-candle (5.38 lx) of light on the parking surface when the area is unoccupied. Lighting devices shall be protected by weather- and vandalism-resistant covers.