Water distribution pipe shall conform to NSF 61 and shall conform to one of the standards listed in Table 18-29-605.5. All hot water distribution pipe and tubing shall have a minimum pressure rating of 100 psi (690 kPa) at 1805°F (825°C).
Material | Standard |
Material | Standard |
Brass pipe | ASTM B43 |
Chlorinated Polyvinyl Chloride (CPVC) plastic pipe and tubing
a
| ASTM D2846; ASTM F441; ASTM F442; CSA B137.6 |
Polypropylene (PP) plastic pipe and tubing a | ASTM F1412 |
PVDF plastic pipe and tubing a | ASTM F1412 |
Copper or copper-alloy pipe | ASTM B42; ASTM B302 |
Copper or copper-alloy tubing (Type K, L, or M) | ASTM B74; ASTM B88; ASTM B251; ASTM B447 |
Galvanized steel pipe | ASTM A53 |
a. For secondary water used in process applications only.