Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
CHAPTER 18-11 RESERVED*
CHAPTER 18-13 RESERVED*
CHAPTER 18-14 BUILDING ENERGY USE BENCHMARKING
CHAPTER 18-27 RESERVED*
CHAPTER 18-28 MECHANICAL SYSTEMS*
CHAPTER 18-29 PLUMBING*
Article 1. Administration (18-29-101 et seq.)
Article 2. Definitions (18-29-201 et seq.)
Article 3. General Regulations (18-29-301 et seq.)
Article 4. Fixtures, Faucets and Fixture Fittings (18-29-401 et seq.)
Article 5. Water Heaters (18-29-501 et seq.)
Article 6. Water Supply and Distribution (18-29-601 et seq.)
18-29-601 General.
18-29-601.1 Scope.
18-29-601.2 Inspections and notices.
18-29-601.3 Access for inspections.
18-29-601.4 Solar energy utilization.
18-29-602 Water Required.
18-29-602.1 General.
18-29-602.1.1 Obligations of water consumers.
18-29-602.1.2 Obligations of water consumers - Private water mains on private property.
18-29-602.2 Potable water required.
18-29-602.3 Deliberately omitted.
18-29-602.4 Reserve water supply.
18-29-602.4.1 Installation of line valves or taps.
18-29-602.4.2 Dual meter settings.
18-29-603 Water Service.
18-29-603.1 Size of water service pipe and water meter.
18-29-603.1.1 Meter spreader connection.
18-29-603.1.2 Water service for fire protection systems.
18-29-603.1.3 Permit required.
18-29-603.2 Separation of water service and building sewer/drain.
18-29-603.2.1 Water supply systems installed near a sewer structure.
18-29-603.2.2 Reserved.
18-29-603.2.3 Backfill.
18-29-603.3 Metered service.
18-29-603.3.1 Authority.
18-29-603.3.2 Connection to metered service.
18-29-603.3.3 Licensed and bonded contractor.
18-29-603.3.4 Location.
18-29-603.3.5 Construction of meter vaults.
18-29-603.3.6 Installation of taps.
18-29-603.3.7 Plans accompany permit application.
18-29-603.3.8 Notification of wrecking buildings for terminating water service.
18-29-604 Design of Building Water Distribution System.
18-29-604.1 General.
18-29-604.2 System interconnection.
18-29-604.3 Water distribution system design criteria.
18-29-604.4 Maximum flow and water consumption.
18-29-604.4.1 WaterSense compliance.
18-29-604.4.2 Reserved.
18-29-604.5 Size of fixture supply.
18-29-604.5.1 Minimum size.
18-29-604.6 Variable street pressures.
18-29-604.7 Inadequate water pressure.
18-29-604.8 Water pressure reducing valve or regulator.
18-29-604.8.1 Reserved.
18-29-604.8.2 Repair and removal.
18-29-604.9 Water hammer.
18-29-604.9.1 Air chambers.
18-29-604.10 Size of water supply pipes.
18-29-604.10.1 Minimum sizes of branch distributing pipes for fixtures and appliances.
18-29-604.10.1.1 Demand load.
18-29-604.10.1.2 Size of piping.
18-29-604.10.1.3 Available pressure.
18-29-604.10.2 Procedures for calculating sizing.
18-29-604.11 Individual pressure balancing in-line valves for individual fixture fittings.
18-29-604.11.1 Reserved.
18-29-605 Materials, Joints and Connections.
18-29-605.1 Water compatibility.
18-29-605.2 Soil and ground water.
18-29-605.3 Lead content of water supply pipe and fittings.
18-29-605.3.1 Lead content of drinking water pipe and fittings.*
18-29-605.4 Water service pipe.
18-29-605.4.1 Materials for supply pipes and fittings.
18-29-605.5 Water distribution pipe.
18-29-605.6 Fittings.
18-29-605.7 Valves.
18-29-605.8 Manufactured pipe nipples.
18-29-605.9 Prohibited joints and connections.
18-29-605.10 Flexible water connectors.
18-29-605.11 Deliberately omitted.
18-29-605.12 Brass.
18-29-605.12.1 Brazed joints.
18-29-605.12.2 Mechanical joints.
18-29-605.12.3 Threaded joints.
18-29-605.12.4 Welded joints.
18-29-605.13 Gray iron and ductile iron joints.
18-29-605.14 Reserved.
18-29-605.14.1 Reserved.
18-29-605.14.2 Reserved.
18-29-605.14.3 Reserved.
18-29-605.14.4 Threaded joints.
18-29-605.14.5 Welded joints.
18-29-605.15 Copper tubing.
18-29-605.15.1 Brazed joints.
18-29-605.15.2 Flared joints.
18-29-605.15.3 Grooved and shouldered mechanical joints.
18-29-605.15.4 Mechanical joints.
18-29-605.15.5 Press-connect joints.
18-29-605.15.6 Soldered joints.
18-29-605.15.7 Push-fit fitting joints.
18-29-605.16 CPVC plastic.
18-29-605.16.1 Mechanical joints.
18-29-605.16.2 Solvent cementing.
18-29-605.16.3 Threaded joints.
18-29-605.17 Steel.
18-29-605.17.1 Threaded joints.
18-29-605.17.2 Mechanical joints.
18-29-605.18 Deliberately omitted.
18-29-605.19 Deliberately omitted.
18-29-605.20 Deliberately omitted.
18-29-605.21 Joints between different materials.
18-29-605.21.1 Copper or copper-alloy tubing to galvanized steel pipe.
18-29-605.22 Protection for pipes and fixtures.
18-29-605.23 Hydrants and non-freeze hydrants protection.
18-29-605.24 Water supply pipe protection.
18-29-605.25 Refrigerant condensers.
18-29-605.26 Dead-ends prohibited.
18-29-605.27 Air conditioning and refrigeration systems.
18-29-605.28 Permissible exceptions.
18-29-606 Installation of the Building Water Distribution System.
18-29-606.1 Location of full-open valves.
18-29-606.2 Location of shutoff valves.
18-29-606.3 Access to valves.
18-29-606.4 Valve identification.
18-29-606.5 Water pressure booster systems.
18-29-606.5.1 Hydropneumatic system, booster pump system, gravity tank.
18-29-606.5.1.1 Requirements.
18-29-606.5.1.1.1 Pressure relief valve.
18-29-606.5.1.1.2 Compression tank.
18-29-606.5.1.1.3 Sludge drain pipe.
18-29-606.5.1.2 Booster pump system.
18-29-606.5.1.2.1 Gravity tanks.
18-29-606.5.1.2.2 Total pressure.
18-29-606.5.1.2.3 Low pressure cutoff.
18-29-606.5.2 Surge tank for pumps.
18-29-606.5.3 Check valves required.
18-29-606.5.3.1 Approval required.
18-29-606.5.4 Equipment required for tanks receiving city water.
18-29-606.5.4.1 Sludge drain pipe.
18-29-606.5.4.2 Size.
18-29-606.5.4.3 Covers and support.
18-29-606.5.5 Recycling system for vehicle wash installations.
18-29-606.5.6 Potable water inlet control and location.
18-29-606.5.7 Tank drain pipes.
18-29-606.5.8 Prohibited location of potable supply tanks.
18-29-606.5.9 Pressure relief valve requirements.
18-29-606.5.10 Pressure relief valves for hydropneumatic tanks.
18-29-606.6 Test of distribution pipes.
18-29-607 Hot Water Supply System.
18-29-607.1 Where required.
18-29-607.1.1 Temperature limiting means.
18-29-607.1.2 Tempered water temperature control.
18-29-607.1.2.1 Reserved.
18-29-607.2 Hot or tempered water supply to fixtures.
18-29-607.2.1 Circulation systems and heat trace systems for maintaining heated water temperature in distribution systems.
18-29-607.2.1.1 Pump controls for hot water storage system.
18-29-607.2.1.2 Demand recirculation controls for distribution systems.
18-29-607.2.1A Reserved.
18-29-607.2.2 Piping for recirculation systems having temperature-actuated mixing valves.
18-29-607.3 Thermal expansion control.
18-29-607.3.1 Reserved.
18-29-607.3.2 Reserved.
18-29-607.4 Flow of hot water to fixtures.
18-29-607.5 Insulation of piping.
18-29-607.6 Expansion joints.
18-29-608 Protection of Potable Water Supply.
18-29-608.1 General.
18-29-608.2 Plumbing fixtures.
18-29-608.3 Water supply pipes.
18-29-608.3.1 Special equipment, water supply protection.
18-29-608.4 Deliberately omitted.
18-29-608.5 Secondary water.
18-29-608.6 Prohibited use of secondary water.
18-29-608.6.1 Private water supplies.
18-29-608.7 Stop-and-waste valves prohibited.
18-29-608.8 Identification of potable and nonpotable water.
18-29-608.9 Re-utilization prohibited.
18-29-608.10 Reuse of piping.
18-29-608.11 Painting of water tanks.
18-29-608.12 Pumps and other appliances.
18-29-608.13 Backflow protection.
18-29-608.13.1 Air gap.
18-29-608.13.2 Reduced pressure principle backflow preventers.
18-29-608.13.3 Backflow preventer with intermediate atmospheric vent.
18-29-608.13.4 Barometric loop.
18-29-608.13.5 Atmospheric-type vacuum breakers.
18-29-608.13.6 Double check-valve assemblies.
18-29-608.14 Location of backflow preventers.
18-29-608.15 Protection of potable water outlets.
18-29-608.16 Connections to the potable water system.
18-29-608.16.1 Beverage carbonator.
18-29-608.16.1.1 Backflow preventer.
18-29-608.16.2 High-pressure steam boilers.
18-29-608.16.3 Connections to automatic fire sprinkler systems and standpipe systems.
18-29-608.16.4 Fire protection equipment, risers, standpipes, tanks to be drained and flushed.
18-29-608.16.5 Fire-extinguishing equipment cross-connection.
18-29-608.16.5.1 Prohibitions.
18-29-608.16.6 Chemical or petroleum pressure vessels.
18-29-608.16.6.1 Chemical or petroleum pressure vessels.
18-29-608.16.6.2 Water flushing or cooling.
18-29-608.16.6.3 Chemical, contaminated water, or sewage lines or vessels.
18-29-608.16.7 Deliberately omitted.
18-29-608.16.8 Portable cleaning equipment.
18-29-608.16.9 Dental pump equipment.
18-29-608.17 Private water supplies.
18-29-608.17.1 Well locations.
18-29-608.17.1.1 Distances.
18-29-608.17.1.2 Direct connections.
18-29-609 Health Care Plumbing.
18-29-609.1 General.
18-29-609.1.1 Where required.
18-29-609.2 Water service.
18-29-609.3 Hot water.
18-29-609.4 Vacuum breaker installation.
18-29-609.5 Prohibited water closet and clinical sink supply.
18-29-609.6 Clinical, hydrotherapeutic and radiological equipment.
18-29-609.7 Condensate drain trap seal.
18-29-609.8 Valve leakage diverter.
18-29-610 Disinfection of Potable Water System.
18-29-610.1 Scope.
18-29-611 Water Treatment Units.
18-29-611.1 Design.
18-29-611.2 Reverse osmosis systems.
Article 7. Sanitary Drainage (18-29-701 et seq.)
Article 8. Indirect/Special Waste (18-29-801 et seq.)
Article 9. Vents (18-29-901 et seq.)
Article 10. Traps, Separators and Interceptors (18-29-1001 et seq.)
Article 11. Storm Drainage (18-29-1101 et seq.)
Article 12. Swimming Pools and Other Swimming Facilities* (18-29-1201 et seq.)
Article 13. Referenced Standards
Appendix A Procedures for Calculating the Minimum Sizing of the Water Supply System
CHAPTER 18-30 RESERVED*
CHAPTER 18-31 RESERVED*
CHAPTER 18-32 RESERVED*
CHAPTER 18-36 REFERENCE STANDARDS*
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
18-29-603.3.2 Connection to metered service.
   Where this chapter requires the water supply for any building, structure, premises, or any part thereof to be under meter control, it shall be unlawful for any person to connect any building, structure, or premises, or any part thereof or addition thereto, with any service or supply pipe other than a service or supply controlled by a water meter. Such water meter shall be installed at the time of connection to the city's water system.
(Amend Coun. J. 7-29-15, p. 3537, § 4)
18-29-603.3.3 Licensed and bonded contractor.
   Where this chapter or the rules or regulations of the Commissioner of Water Management provide for the installation of a water meter on any service pipe supplying water from the Chicago Waterworks System to any building, structure, or premises, such meter shall be installed by a licensed and bonded plumbing contractor.
(Amend Coun. J. 10-14-21, p. 37722, Art. VI, § 4)
18-29-603.3.4 Location.
   The location of such meter, either inside or outside of any building or structure, shall be determined in writing by the Commissioner of Water Management in accordance with this section. The installation of any water meter at any location other than that permitted by said Commissioner is prohibited. Installation of any water meter shall be in accordance with the following:
   1.   No meter may be installed within a dwelling unit in a building containing more than three dwelling units or where the meter serves more than three dwelling units.
   2.   For services 1 inch (25 mm), 1 1/2 inches (40 mm) or 2 inches (50 mm) diameter: Meters shall be installed within 2 feet (610 mm) of the front wall of the building. The maximum distance a meter may be installed from the property line to meter is 50 feet (15.25 m). Any installation of a service 1 inch (25 mm), 1 1/2 inches (40 mm) and 2 inches (50 mm) over 50 feet (15.25 m) will require the installation of a meter vault in the public way.
   3.   For services 3 inches (75 mm) diameter and above: Meters shall be installed within 4 feet (1220 mm) of the front wall of the building. The maximum distance the meters may be installed from property line is 100 feet (30.5 m). A meter vault is required in the public way in any circumstance in which the distance from the property line to the meters exceeds 100 feet (30.5 m). Any installation in excess of 100 feet (30.5 m) will require the installation of a meter vault in the public way.
   4.   All new combination (fire and domestic) service shall require a domestic meter and an approved backflow device with bypass meter for the fire system. If these services are in excess of the 50' for 2 inches (15.25 m:50 mm) or 100' for 3 inches (30.5 m:75 mm) they must meet the above requirement and shall require the backflow preventer to be installed in an above ground-heated enclosure "hot box," located as close to the property line as physically possible.
   5.   Service used in conjunction with trunk lines (private water mains) requiring private fire hydrants shall have compound meters installed in a meter vault in the public way. Private hydrants are to be painted federal safety green.
\(Amend Coun. J. 11-8-12, p. 38872, § 344; Amend Coun. J. 10-14-21, p. 37722, Art. VI, § 4)
18-29-603.3.5 Construction of meter vaults.
   Wherever a water meter is installed in the ground, either inside or outside of any building or structure on public or privately owned property, it shall be enclosed in a meter vault. Such vault shall be built of hard pressed common brick or portland cement concrete blocks laid up in portland cement mortar, poured portland cement concrete, extra heavy, salt-glazed vitrified clay tile pipe, portland cement concrete pipe, or equally durable material. This meter vault shall be provided with a removable cover. Each meter vault shall be built to conform to the specifications and dimensions for meter vaults issued by the Commissioner of Water Management.
(Amend Coun. J. 11-8-12, p. 38872, § 345; Amend Coun. J. 10-14-21, p. 37722, Art. VI, § 4; Amend Coun. J. 12-14-22, p. 58278, Art. VI, § 7; Amend Coun. J. 4-19-23, p. 62477, § 1)
18-29-603.3.6 Installation of taps.
   No water main shall be tapped other than by a tapper employed by the Department of Water Management or a contractor hired by the Department of Water Management for lead service line replacement, and all tapping shall be performed only under the authority of the Commissioner of Water Management. All service cocks or ferrules must be inserted at or near the top of the street main, and not nearer than 6 inches (150 mm) from the bell of the pipe. The size of the cock shall be that specified in the permit. Each service pipe shall have its own independent tap at the main and said tap shall be of the type in use by the Department of Water Management.
(Amend Coun. J. 11-8-12, p. 38872, § 346; Amend Coun. J. 10-14-21, p. 37722, Art. VI, § 4; Amend Coun. J. 12-16-24, p. 22879, Art. I, § 7)
18-29-603.3.7 Plans accompany permit application.
   No permit for the installation of any pipe or system of piping taking water from the Chicago Waterworks System for distribution in any building or structure shall be granted until a plan of such water supply or distribution system has been examined and approved by the Commissioner of Buildings or Commissioner of Water Management. Such plan or plans shall be presented with the application for permit and shall clearly show the complete water supply piping system from the service to the plumbing fixtures and other appliances including fire protection equipment, to which such water supply piping system is connected, together with detail drawings of connections to surge tanks, storage tanks, pressure tanks, filters, swimming pools, bathing and display pools, hydrotherapy pools, sterilizers, condensers, compressors, reservoirs, and washers.
   For private water systems within the City of Chicago the owner, agent, contractor or permittee shall provide to the Commissioner of Water Management an as-built drawing within 30 days of completion of the private water system. The as-built drawing shall identify the location and size for every main, control valve, meter vault, fire hydrant, line valve, service valve, meter and individual service location connected to the Chicago Water Works System.
(Amend Coun. J. 11-8-12, p. 38872, § 347; Amend Coun. J. 10-14-21, p. 37722, Art. VI, § 4)
18-29-603.3.8 Notification of wrecking buildings for terminating water service.
   No building, structure, or premises shall be permanently abandoned, wrecked, or destroyed without the previous notification, in writing, to the Commissioner of Water Management of such abandonment, wrecking or destroying, in order that the water service may be shut off, and leaking or wasting water shall be eliminated or prevented; and accompanying said notification, ample financial provisions, such as the deposit of the estimated costs of disconnection and sealing of water service pipes or posting of a surety bond, shall be made to the satisfaction of the Commissioner of Water Management to ensure the payment of all costs and charges for the shutting off of said water service. Such notification and assurance of payment shall be given by the person in charge of the wrecking or destroying of the building or by the owner of the building, structure, or premises.
   No person, other than employees, agents or contractors of the Department of Water Management, shall be allowed to operate any line valve in any water main. Such employees, agents and contractors shall follow the Department's written policy for service terminations. If the termination is not performed pursuant to the Department's written policy, in addition to other applicable remedies, the Commissioner of Water Management may repair the defective termination at the owner's expense, require the owner to repair the defective termination, or terminate any new water service to the building at the owner's expense.
(Amend Coun. J. 11-8-12, p. 38872, § 348; Amend Coun. J. 7-29-15, p. 3537, § 4; Amend Coun. J. 10-14-21, p. 37722, Art. VI, § 4)