Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
CHAPTER 18-11 RESERVED*
CHAPTER 18-13 RESERVED*
CHAPTER 18-14 BUILDING ENERGY USE BENCHMARKING
CHAPTER 18-27 RESERVED*
CHAPTER 18-28 MECHANICAL SYSTEMS*
CHAPTER 18-29 PLUMBING*
Article 1. Administration (18-29-101 et seq.)
Article 2. Definitions (18-29-201 et seq.)
Article 3. General Regulations (18-29-301 et seq.)
Article 4. Fixtures, Faucets and Fixture Fittings (18-29-401 et seq.)
18-29-401 General.
18-29-401.1 Scope.
18-29-401.2 Prohibited fixtures and connections.
18-29-401.3 Water conservation.
18-29-401.4 Reserved.
18-29-401.5 Reserved.
18-29-401.6 Conflicts.
18-29-402 Fixture Materials.
18-29-402.1 Quality of fixtures.
18-29-402.1.1 Used fixtures.
18-29-402.2 Materials for specialty fixtures.
18-29-402.3 Sheet copper.
18-29-402.4 Sheet lead.
18-29-402.5 Fixture strainer.
18-29-402.6 Fixture overflow.
18-29-403 Minimum Plumbing Facilities.
18-29-403.1 Minimum number of fixtures.
18-29-403.1.1 Number of occupants.
18-29-403.1.2 Minimum fixture calculations.
18-29-403.1.3 Single-user toilet rooms and bathing rooms.
18-29-403.1.3.1 Signage.
18-29-403.1.3.2 Lock.
18-29-403.1.3.3 Enclosure.
18-29-403.1.3.4 Waste receptacle.
18-29-403.1.4 Lavatory distribution.
18-29-403.2 Separate facilities.
18-29-403.2.1 Nonseparate facilities.
18-29-403.2.1.1 Number of fixtures.
18-29-403.2.1.2 Water closet compartments.
18-29-403.2.1.2.1 Enclosure.
18-29-403.2.1.2.2 Lock.
18-29-403.2.1.2.3 Waste receptacle.
18-29-403.2.1.3 Urinals.
18-29-403.2.1.4 Proximity to single-user toilet room.
18-29-403.2.1.5 Entrance.
18-29-403.3 Public and employee toilet facilities.
18-29-403.3.1 Access.
18-29-403.3.2 Prohibited location.
18-29-403.3.3 Location.
18-29-403.3.4 Reserved.
18-29-403.3.5 Pay facilities.
18-29-403.3.6 Door locking.
18-29-403.4 Reserved.
18-29-403.5 Drinking fountain location.
18-29-403.6 Service sink location.
18-29-403.6.1 Reserved.
18-29-403.6.1.1 Reserved.
18-29-403.7 Community toilet facilities.
18-29-403.8 Reserved.
18-29-403.9 Reserved.
18-29-404 Accessible Plumbing Facilities.
18-29-404.1 Where required.
18-29-404.2 Accessible fixture requirements.
18-29-405 Installation of Fixtures.
18-29-405.1 Water supply protection.
18-29-405.2 Access for cleaning.
18-29-405.2.1 Reserved.
18-29-405.2.2 Reserved.
18-29-405.3 Setting.
18-29-405.3.1 Water closets, lavatories and bidets.
18-29-405.3.2 Access to lavatories.
18-29-405.3.3 Location of fixtures and piping.
18-29-405.3.4 Water closet compartment.
18-29-405.3.5 Urinal partitions.
18-29-405.4 Floor and wall drainage connections.
18-29-405.4.1 Floor flanges.
18-29-405.4.1.1 Hard lead floor flanges.
18-29-405.4.2 Securing floor outlet fixtures.
18-29-405.4.3 Securing wall-hung water closet bowls.
18-29-405.5 Water-tight joints.
18-29-405.6 Plumbing in mental health centers.
18-29-405.7 Design of overflows.
18-29-405.7.1 Connection of overflows.
18-29-405.8 Access to concealed connections.
18-29-406 Automatic Clothes Washers.
18-29-406.1 Water connection.
18-29-406.2 Waste connection.
18-29-406.3 Reserved.
18-29-407 Bathtubs.
18-29-407.1 Approval.
18-29-407.2 Bathtub waste outlets.
18-29-407.3 Glazing.
18-29-408 Bidets.
18-29-408.1 Approval.
18-29-408.2 Water connection.
18-29-409 Dishwashing Machines.
18-29-409.1 Approval.
18-29-409.2 Water connection.
18-29-409.2.1 Reserved.
18-29-409.2.2 Reserved.
18-29-409.3 Waste connection.
18-29-409.3.1 Reserved.
18-29-409.4 Residential dishwasher waste connection.
18-29-410 Drinking Fountains.
18-29-410.1 Approval.
18-29-410.2 Reserved.
18-29-410.3 Accessible drinking fountains.
18-29-410.4 Substitution.
18-29-410.5 Prohibited location.
18-29-411 Emergency Showers and Eyewash Stations.
18-29-411.1 Water connection.
18-29-411.2 Waste connection.
18-29-412 Floor and Trench Drains.
18-29-412.1 Approval.
18-29-412.2 Floor drains.
18-29-412.3 Size of floor drains.
18-29-412.4 Where required.
18-29-412.4.1 Reserved.
18-29-412.4.2 Reserved.
18-29-412.4.3 Reserved.
18-29-412.4.4 Reserved.
18-29-412.4.5 Reserved.
18-29-412.4.6 Reserved.
18-29-412.4.7 Reserved.
18-29-412.4.8 Reserved.
18-29-412.4.9 Reserved.
18-29-412.5 Floor slope.
18-29-413 Food Waste Disposer Units.
18-29-413.1 Approval.
18-29-413.2 Domestic food waste disposer waste outlets.
18-29-413.3 Commercial food waste disposer waste outlets.
18-29-413.4 Water supply required.
18-29-414 Garbage Can Washers.
18-29-414.1 Water connection.
18-29-414.2 Waste connection.
18-29-415 Laundry Trays.
18-29-415.1 Approval.
18-29-415.2 Waste outlet.
18-29-416 Lavatories.
18-29-416.1 Approval.
18-29-416.2 Cultured marble lavatories.
18-29-416.3 Lavatory waste outlets.
18-29-416.4 Movable lavatory systems.
18-29-416.5 Tempered water for public handwashing facilities.
18-29-417 Showers.
18-29-417.1 Approval.
18-29-417.2 Water supply riser.
18-29-417.3 Shower waste outlet.
18-29-417.4 Shower compartments.
18-29-417.4.1 Deliberately omitted.
18-29-417.4.2 Wall area.
18-29-417.4.3 Shower installation.
18-29-417.4.4 Water temperature safety.
18-29-417.4.5 Dimensions.
18-29-417.4.6 Materials.
18-29-417.4.7 Public or institution showers.
18-29-417.5 Shower floor or receptors.
18-29-417.5.1 Support.
18-29-417.5.2 Deliberately omitted.
18-29-417.6 Glazing.
18-29-418 Sinks.
18-29-418.1 Approval.
18-29-418.2 Sink waste outlets.
18-29-418.2.1 Facilities with no range oven.
18-29-418.3 Movable sink systems.
18-29-419 Urinals.
18-29-419.1 Approval.
18-29-419.2 Substitution for water closets.
18-29-419.3 Urinals for public or employee toilet facilities.
18-29-419.4 Surrounding material.
18-29-420 Water Closets.
18-29-420.1 Approval.
18-29-420.2 Water closets for public or employee toilet facilities.
18-29-420.3 Water closet seats.
18-29-420.4 Water closet connections.
18-29-420.5 Deliberately omitted.
18-29-420.6 Chemical closets.
18-29-420.7 Reserved.
18-29-421 Whirlpool Bathtubs.
18-29-421.1 Approval.
18-29-421.2 Installation.
18-29-421.3 Drain.
18-29-421.4 Suction fittings.
18-29-422 Health Care Fixtures and Equipment.
18-29-422.1 Scope.
18-29-422.2 Deliberately omitted.
18-29-422.3 Deliberately omitted.
18-29-422.4 Deliberately omitted.
18-29-422.5 Deliberately omitted.
18-29-422.6 Deliberately omitted.
18-29-422.7 Deliberately omitted.
18-29-422.8 Deliberately omitted.
18-29-422.9 Sterilizer equipment requirements.
18-29-422.9.1 Sterilizer piping.
18-29-422.9.2 Steam supply.
18-29-422.9.3 Steam condensate return.
18-29-422.9.4 Condensers.
18-29-422.10 Special elevations.
18-29-423 Specialty Plumbing Fixtures.
18-29-423.1 Water connections.
18-29-423.2 Approval.
18-29-423.3 Footbaths and pedicure baths.
18-29-424 Faucets and Fixture Fittings.
18-29-424.1 Approval.
18-29-424.1.1 Faucets and supply fittings.
18-29-424.1.2 Waste fittings.
18-29-424.2 Hand showers.
18-29-424.3 Individual shower valves.
18-29-424.4 Multiple (gang) showers.
18-29-424.5 Bathtub and whirlpool bathtub valves.
18-29-424.6 Hose-connected outlets.
18-29-424.7 Temperature-actuated, flow-reduction devices for individual fixture fittings.
18-29-424.8 Transfer valves.
18-29-424.9 Water closet personal hygiene devices.
18-29-424.10 Head shampoo sink faucets.
18-29-424.11 Prerinse spray valve.
18-29-425 Flushing Devices for Water Closets and Urinals.
18-29-425.1 Flushing devices required.
18-29-425.1.1 Separate for each fixture.
18-29-425.2 Flushometer valves and tanks.
18-29-425.3 Flush tanks.
18-29-425.3.1 Ball cocks.
18-29-425.3.2 Overflows in flush tanks.
18-29-425.3.3 Sheet copper.
18-29-425.3.4 Access required.
18-29-425.4 Flush pipes and fittings.
18-29-426 Floor Sinks.
18-29-426.1 Approval.
Article 5. Water Heaters (18-29-501 et seq.)
Article 6. Water Supply and Distribution (18-29-601 et seq.)
Article 7. Sanitary Drainage (18-29-701 et seq.)
Article 8. Indirect/Special Waste (18-29-801 et seq.)
Article 9. Vents (18-29-901 et seq.)
Article 10. Traps, Separators and Interceptors (18-29-1001 et seq.)
Article 11. Storm Drainage (18-29-1101 et seq.)
Article 12. Swimming Pools and Other Swimming Facilities* (18-29-1201 et seq.)
Article 13. Referenced Standards
Appendix A Procedures for Calculating the Minimum Sizing of the Water Supply System
CHAPTER 18-30 RESERVED*
CHAPTER 18-31 RESERVED*
CHAPTER 18-32 RESERVED*
CHAPTER 18-36 REFERENCE STANDARDS*
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
18-29-424.1.2 Waste fittings.
   Waste fittings shall conform to ASME A112.18.2/CSA B125.2, ASTM F409 or to one of the standards listed in Table 18-29-702.4 for aboveground drainage and vent pipe and fittings.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.2 Hand showers.
   Hand-held showers shall conform to ASME A112.18.1/CSA B125.1. Hand-held showers shall provide backflow protection in accordance with ASME A112.18.1/CSA B125.1 or shall be protected against backflow by a device complying with ASME A112.18.3.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.3 Individual shower valves.
   Individual shower and tub-shower combination valves shall be balanced-pressure, thermostatic or combination balanced-pressure/thermostatic valves that conform to the requirements of ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1. Such valves shall be installed at the point of use. Shower control valves shall be rated for the flow rate of the installed shower head. Shower and tub-shower combination valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be field adjusted in accordance with the manufacturer's instructions to provide water at a temperature not to exceed 120°F (49°C). In-line thermostatic valves shall not be utilized for compliance with this section.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.4 Multiple (gang) showers.
   Multiple (gang) showers supplied with a single, tempered water supply pipe shall have the water supply for such showers controlled by an automatic temperature control mixing valve that conforms to ASSE 1069 or CSA B125.3, or each shower head shall be individually controlled by a balanced-pressure, thermostatic or combination balanced-pressure/thermostatic valve that conform to ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1 and that is installed at the point of use. Where a shower head is individually controlled, shower control valves shall be rated for the flow rate of the installed shower head. Such valves shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be field adjusted in accordance with the manufacturer's instructions to provide water at a temperature not to exceed 120°F (49°C). Access shall be provided to an ASSE 1069 or CSA B125.3 valve.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.5 Bathtub and whirlpool bathtub valves.
   Bathtub and whirlpool bathtub valves shall have or be supplied by a water-temperature-limiting device that conforms to ASSE 1070/ASME A112.1070/CSA B125.70 or by a water heater complying with ASSE 1082 or ASSE 1084, except where such valves are combination tub/shower valves in accordance with Section 18-29-424.3. The water-temperature-limiting device required by this section shall be equipped with a means to limit the maximum setting of the device to 120°F (49°C), and, where adjustable, shall be field adjusted in accordance with the manufacturer's instructions to provide water at a temperature not to exceed 120°F (49°C). Access shall be provided to water-temperature-limiting devices that conform to ASSE 1070/ASME A112.1070/CSA B125.70.
   Exception: Access shall not be required for nonadjustable water-temperature-limiting devices that conform to ASSE 1070/ASME A112.1070/CSA B125.70 and are integral with a fixture fitting, provided that the fixture fitting itself can be accessed for replacement.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.6 Hose-connected outlets.
   Faucets and fixture fittings with hose-connected outlets shall conform to ASME A112.18.3 or ASME A112.18.1/CSA B125.1.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.7 Temperature-actuated, flow-reduction devices for individual fixture fittings.
   Temperature-actuated, flow-reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. A temperature-actuated, flow-reduction device shall be an acceptable method for limiting the water temperature to not greater than 120°F (49°C) at the outlet of a faucet or fixture fitting. Such devices shall not be used alone as a substitute for the balanced-pressure, thermostatic or combination shower valves required in Section 18-29-424.3 or as a substitute for bathtub or whirlpool bathtub water-temperature-limiting valves required in Section 18-29-424.5.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.8 Transfer valves.
   Deck-mounted bath/shower transfer valves containing an integral atmospheric vacuum breaker shall conform to the requirements of ASME A112.4.2/CSA B125.1.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 23)