18-29-423 Specialty Plumbing Fixtures.
18-29-423.1 Water connections.
   Baptisteries, ornamental and lily pools, aquariums, ornamental fountain basins, swimming pools, and similar constructions, where provided with water supplies, shall be protected against backflow in accordance with Section 18-29-608.
18-29-423.2 Approval.
   Specialties requiring water and waste connections shall be submitted for approval.
18-29-423.3 Footbaths and pedicure baths.
   The water supplied to specialty plumbing fixtures, such as pedicure chairs having an integral foot bathtub and footbaths, shall be limited to not greater than 120°F (49°C) by a water-temperature-limiting device that conforms to ASSE 1070/ASME A112.1070/CSA B125.70 or by a water heater complying with ASSE 1082.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 22)
18-29-424 Faucets and Fixture Fittings.
18-29-424.1 Approval.
   Faucets and fixture fittings shall conform to ASME A112.18.1/CSA B125.1. Faucets and fixture fittings that supply drinking water for human ingestion shall conform to the requirements of NSF 61, Section 9. Flexible water connectors exposed to continuous pressure shall conform to the requirements of Section 18-29-605.10.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.1.1 Faucets and supply fittings.
   Faucets and supply fittings shall conform to the water consumption requirements of Section 18-29-604.4.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 23)
18-29-424.1.2 Waste fittings.
   Waste fittings shall conform to ASME A112.18.2/CSA B125.2, ASTM F409 or to one of the standards listed in Table 18-29-702.4 for aboveground drainage and vent pipe and fittings.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 23)