Loading...
18-29-417.5.2 Deliberately omitted.
18-29-417.6 Glazing.
   Windows and doors within a shower enclosure shall conform to the safety glazing requirements of the building code.
18-29-418 Sinks.
18-29-418.1 Approval.
   Sinks shall conform to ANSI Z124.6, ASME A112.19.1, ASME A112.19.2, ASME A112.19.3, ASME A112.19.4, ASME A112.19.9, CSA B45.1, CSA B45.2, CSA B45.3 or CSA B45.4.
18-29-418.2 Sink waste outlets.
   Sinks shall be provided with waste outlets a minimum of 1 1/2 inches (38 mm) in diameter. A strainer or crossbar shall be provided to restrict the clear opening of the waste outlet. Sinks on which a food waste grinder is installed shall have a waste opening a minimum of 3 1/2 inches (89 mm) in diameter.
18-29-418.2.1 Facilities with no range oven.
   Sinks installed in lunchrooms, pantries, break rooms and other similar facilities where no range or oven is installed shall not be required to have a grease interceptor. Installation of a microwave oven in such facilities shall require the installation of a grease interceptor.
(Amend Coun. J. 3-27-02, p. 82090, § 3)
18-29-418.3 Movable sink systems.
   Movable sink systems shall comply with ASME A112.19.12.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 18)
18-29-419 Urinals.
18-29-419.1 Approval.
   Urinals shall conform to ASME A112.19.2, CSA B45.1 or CSA B45.5. Urinals shall conform to the water consumption requirements of Section 18-29-604.4. Urinals shall conform to the hydraulic performance requirements of ASME A112.19.6, CSA B45.1 or CSA B45.5.
Loading...