Floors or receptors under shower compartments shall be laid on, and supported by, a smooth and structurally sound base. Support for shower compartments shall comply with the following requirements:
1. Plasticized polyvinyl chloride (PVC) sheet shall be a minimum of 0.040 inch (1 mm) thick, and shall meet the requirements of ASTM D4551. Sheets shall be joined by solvent welding in accordance with the manufacturer's instructions.
2. Non-plasticized chlorinated polyethylene (PE) sheet shall be a minimum 0.040 inch (1.02 mm) thick.
3. Other materials of similar durability and water resistance may be used provided they are approved by the buildings commissioner.
Sinks shall be provided with waste outlets a minimum of 1 1/2 inches (38 mm) in diameter. A strainer or crossbar shall be provided to restrict the clear opening of the waste outlet. Sinks on which a food waste grinder is installed shall have a waste opening a minimum of 3 1/2 inches (89 mm) in diameter.
Sinks installed in lunchrooms, pantries, break rooms and other similar facilities where no range or oven is installed shall not be required to have a grease interceptor. Installation of a microwave oven in such facilities shall require the installation of a grease interceptor.
(Amend Coun. J. 3-27-02, p. 82090, § 3)