18-29-412.4.9 Reserved.
Editor's note – Coun. J. 10-14-21, p. 37722, Art. IV, § 15, repealed § 18-29-412.4.9, which pertained to floor drains in food establishments.
18-29-412.5 Floor slope.
   Where floor drains are provided, floors shall be sloped to the floor drains.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 15)
18-29-413 Food Waste Disposer Units.
18-29-413.1 Approval.
   Domestic food waste disposers shall conform to ASSE 1008 and shall be listed and labeled in accordance with UL 430. Commercial food waste disposers shall be listed and labeled in accordance with UL 430. Food waste disposers shall not increase the drainage fixture unit load on the sanitary drainage system.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 16)
18-29-413.2 Domestic food waste disposer waste outlets.
   Domestic food waste disposers shall be connected to a drain of not less than 1 1/2 inches (38 mm) in diameter.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 16)
18-29-413.3 Commercial food waste disposer waste outlets.
   Commercial food waste disposers shall be connected to a drain not less than 2 inches (51 mm) in diameter. Commercial food waste disposers shall be connected and trapped separately from any other fixtures or sink compartments.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 16; Amend Coun. J. 12-14-22, p. 58278, Art. VI, § 6)
18-29-413.4 Water supply required.
   Food waste disposers shall be provided with a supply of cold water. The water supply shall be protected against backflow by an air gap or backflow preventer in accordance with Section 18-29-608.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 16)