Sinks installed in lunchrooms, pantries, break rooms and other similar facilities where no range or oven is installed shall not be required to have a grease interceptor. Installation of a microwave oven in such facilities shall require the installation of a grease interceptor.
(Amend Coun. J. 3-27-02, p. 82090, § 3)
Urinals shall conform to ASME A112.19.2, CSA B45.1 or CSA B45.5. Urinals shall conform to the water consumption requirements of Section 18-29-604.4. Urinals shall conform to the hydraulic performance requirements of ASME A112.19.6, CSA B45.1 or CSA B45.5.
In each toilet facility, urinals shall not be substituted for more than 67 percent of the required water closets in separate facilities in assembly and educational occupancies. Urinals shall not be substituted for more than 50 percent of the required water closets in separate facilities in all other occupancies. Urinals shall not be substituted for more than 20 percent of the required water closets in nonseparate facilities.
Exception: Male urinals shall be provided in sports or entertainment arenas, stadiums, community or convention halls, special events centers and amusement facilities in quantities required by the Illinois Equitable Restroom Act.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 19)