Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
CHAPTER 18-11 RESERVED*
CHAPTER 18-13 RESERVED*
CHAPTER 18-14 BUILDING ENERGY USE BENCHMARKING
CHAPTER 18-27 RESERVED*
CHAPTER 18-28 MECHANICAL SYSTEMS*
CHAPTER 18-29 PLUMBING*
Article 1. Administration (18-29-101 et seq.)
Article 2. Definitions (18-29-201 et seq.)
Article 3. General Regulations (18-29-301 et seq.)
Article 4. Fixtures, Faucets and Fixture Fittings (18-29-401 et seq.)
18-29-401 General.
18-29-401.1 Scope.
18-29-401.2 Prohibited fixtures and connections.
18-29-401.3 Water conservation.
18-29-401.4 Reserved.
18-29-401.5 Reserved.
18-29-401.6 Conflicts.
18-29-402 Fixture Materials.
18-29-402.1 Quality of fixtures.
18-29-402.1.1 Used fixtures.
18-29-402.2 Materials for specialty fixtures.
18-29-402.3 Sheet copper.
18-29-402.4 Sheet lead.
18-29-402.5 Fixture strainer.
18-29-402.6 Fixture overflow.
18-29-403 Minimum Plumbing Facilities.
18-29-403.1 Minimum number of fixtures.
18-29-403.1.1 Number of occupants.
18-29-403.1.2 Minimum fixture calculations.
18-29-403.1.3 Single-user toilet rooms and bathing rooms.
18-29-403.1.3.1 Signage.
18-29-403.1.3.2 Lock.
18-29-403.1.3.3 Enclosure.
18-29-403.1.3.4 Waste receptacle.
18-29-403.1.4 Lavatory distribution.
18-29-403.2 Separate facilities.
18-29-403.2.1 Nonseparate facilities.
18-29-403.2.1.1 Number of fixtures.
18-29-403.2.1.2 Water closet compartments.
18-29-403.2.1.2.1 Enclosure.
18-29-403.2.1.2.2 Lock.
18-29-403.2.1.2.3 Waste receptacle.
18-29-403.2.1.3 Urinals.
18-29-403.2.1.4 Proximity to single-user toilet room.
18-29-403.2.1.5 Entrance.
18-29-403.3 Public and employee toilet facilities.
18-29-403.3.1 Access.
18-29-403.3.2 Prohibited location.
18-29-403.3.3 Location.
18-29-403.3.4 Reserved.
18-29-403.3.5 Pay facilities.
18-29-403.3.6 Door locking.
18-29-403.4 Reserved.
18-29-403.5 Drinking fountain location.
18-29-403.6 Service sink location.
18-29-403.6.1 Reserved.
18-29-403.6.1.1 Reserved.
18-29-403.7 Community toilet facilities.
18-29-403.8 Reserved.
18-29-403.9 Reserved.
18-29-404 Accessible Plumbing Facilities.
18-29-404.1 Where required.
18-29-404.2 Accessible fixture requirements.
18-29-405 Installation of Fixtures.
18-29-405.1 Water supply protection.
18-29-405.2 Access for cleaning.
18-29-405.2.1 Reserved.
18-29-405.2.2 Reserved.
18-29-405.3 Setting.
18-29-405.3.1 Water closets, lavatories and bidets.
18-29-405.3.2 Access to lavatories.
18-29-405.3.3 Location of fixtures and piping.
18-29-405.3.4 Water closet compartment.
18-29-405.3.5 Urinal partitions.
18-29-405.4 Floor and wall drainage connections.
18-29-405.4.1 Floor flanges.
18-29-405.4.1.1 Hard lead floor flanges.
18-29-405.4.2 Securing floor outlet fixtures.
18-29-405.4.3 Securing wall-hung water closet bowls.
18-29-405.5 Water-tight joints.
18-29-405.6 Plumbing in mental health centers.
18-29-405.7 Design of overflows.
18-29-405.7.1 Connection of overflows.
18-29-405.8 Access to concealed connections.
18-29-406 Automatic Clothes Washers.
18-29-406.1 Water connection.
18-29-406.2 Waste connection.
18-29-406.3 Reserved.
18-29-407 Bathtubs.
18-29-407.1 Approval.
18-29-407.2 Bathtub waste outlets.
18-29-407.3 Glazing.
18-29-408 Bidets.
18-29-408.1 Approval.
18-29-408.2 Water connection.
18-29-409 Dishwashing Machines.
18-29-409.1 Approval.
18-29-409.2 Water connection.
18-29-409.2.1 Reserved.
18-29-409.2.2 Reserved.
18-29-409.3 Waste connection.
18-29-409.3.1 Reserved.
18-29-409.4 Residential dishwasher waste connection.
18-29-410 Drinking Fountains.
18-29-410.1 Approval.
18-29-410.2 Reserved.
18-29-410.3 Accessible drinking fountains.
18-29-410.4 Substitution.
18-29-410.5 Prohibited location.
18-29-411 Emergency Showers and Eyewash Stations.
18-29-411.1 Water connection.
18-29-411.2 Waste connection.
18-29-412 Floor and Trench Drains.
18-29-412.1 Approval.
18-29-412.2 Floor drains.
18-29-412.3 Size of floor drains.
18-29-412.4 Where required.
18-29-412.4.1 Reserved.
18-29-412.4.2 Reserved.
18-29-412.4.3 Reserved.
18-29-412.4.4 Reserved.
18-29-412.4.5 Reserved.
18-29-412.4.6 Reserved.
18-29-412.4.7 Reserved.
18-29-412.4.8 Reserved.
18-29-412.4.9 Reserved.
18-29-412.5 Floor slope.
18-29-413 Food Waste Disposer Units.
18-29-413.1 Approval.
18-29-413.2 Domestic food waste disposer waste outlets.
18-29-413.3 Commercial food waste disposer waste outlets.
18-29-413.4 Water supply required.
18-29-414 Garbage Can Washers.
18-29-414.1 Water connection.
18-29-414.2 Waste connection.
18-29-415 Laundry Trays.
18-29-415.1 Approval.
18-29-415.2 Waste outlet.
18-29-416 Lavatories.
18-29-416.1 Approval.
18-29-416.2 Cultured marble lavatories.
18-29-416.3 Lavatory waste outlets.
18-29-416.4 Movable lavatory systems.
18-29-416.5 Tempered water for public handwashing facilities.
18-29-417 Showers.
18-29-417.1 Approval.
18-29-417.2 Water supply riser.
18-29-417.3 Shower waste outlet.
18-29-417.4 Shower compartments.
18-29-417.4.1 Deliberately omitted.
18-29-417.4.2 Wall area.
18-29-417.4.3 Shower installation.
18-29-417.4.4 Water temperature safety.
18-29-417.4.5 Dimensions.
18-29-417.4.6 Materials.
18-29-417.4.7 Public or institution showers.
18-29-417.5 Shower floor or receptors.
18-29-417.5.1 Support.
18-29-417.5.2 Deliberately omitted.
18-29-417.6 Glazing.
18-29-418 Sinks.
18-29-418.1 Approval.
18-29-418.2 Sink waste outlets.
18-29-418.2.1 Facilities with no range oven.
18-29-418.3 Movable sink systems.
18-29-419 Urinals.
18-29-419.1 Approval.
18-29-419.2 Substitution for water closets.
18-29-419.3 Urinals for public or employee toilet facilities.
18-29-419.4 Surrounding material.
18-29-420 Water Closets.
18-29-420.1 Approval.
18-29-420.2 Water closets for public or employee toilet facilities.
18-29-420.3 Water closet seats.
18-29-420.4 Water closet connections.
18-29-420.5 Deliberately omitted.
18-29-420.6 Chemical closets.
18-29-420.7 Reserved.
18-29-421 Whirlpool Bathtubs.
18-29-421.1 Approval.
18-29-421.2 Installation.
18-29-421.3 Drain.
18-29-421.4 Suction fittings.
18-29-422 Health Care Fixtures and Equipment.
18-29-422.1 Scope.
18-29-422.2 Deliberately omitted.
18-29-422.3 Deliberately omitted.
18-29-422.4 Deliberately omitted.
18-29-422.5 Deliberately omitted.
18-29-422.6 Deliberately omitted.
18-29-422.7 Deliberately omitted.
18-29-422.8 Deliberately omitted.
18-29-422.9 Sterilizer equipment requirements.
18-29-422.9.1 Sterilizer piping.
18-29-422.9.2 Steam supply.
18-29-422.9.3 Steam condensate return.
18-29-422.9.4 Condensers.
18-29-422.10 Special elevations.
18-29-423 Specialty Plumbing Fixtures.
18-29-423.1 Water connections.
18-29-423.2 Approval.
18-29-423.3 Footbaths and pedicure baths.
18-29-424 Faucets and Fixture Fittings.
18-29-424.1 Approval.
18-29-424.1.1 Faucets and supply fittings.
18-29-424.1.2 Waste fittings.
18-29-424.2 Hand showers.
18-29-424.3 Individual shower valves.
18-29-424.4 Multiple (gang) showers.
18-29-424.5 Bathtub and whirlpool bathtub valves.
18-29-424.6 Hose-connected outlets.
18-29-424.7 Temperature-actuated, flow-reduction devices for individual fixture fittings.
18-29-424.8 Transfer valves.
18-29-424.9 Water closet personal hygiene devices.
18-29-424.10 Head shampoo sink faucets.
18-29-424.11 Prerinse spray valve.
18-29-425 Flushing Devices for Water Closets and Urinals.
18-29-425.1 Flushing devices required.
18-29-425.1.1 Separate for each fixture.
18-29-425.2 Flushometer valves and tanks.
18-29-425.3 Flush tanks.
18-29-425.3.1 Ball cocks.
18-29-425.3.2 Overflows in flush tanks.
18-29-425.3.3 Sheet copper.
18-29-425.3.4 Access required.
18-29-425.4 Flush pipes and fittings.
18-29-426 Floor Sinks.
18-29-426.1 Approval.
Article 5. Water Heaters (18-29-501 et seq.)
Article 6. Water Supply and Distribution (18-29-601 et seq.)
Article 7. Sanitary Drainage (18-29-701 et seq.)
Article 8. Indirect/Special Waste (18-29-801 et seq.)
Article 9. Vents (18-29-901 et seq.)
Article 10. Traps, Separators and Interceptors (18-29-1001 et seq.)
Article 11. Storm Drainage (18-29-1101 et seq.)
Article 12. Swimming Pools and Other Swimming Facilities* (18-29-1201 et seq.)
Article 13. Referenced Standards
Appendix A Procedures for Calculating the Minimum Sizing of the Water Supply System
CHAPTER 18-30 RESERVED*
CHAPTER 18-31 RESERVED*
CHAPTER 18-32 RESERVED*
CHAPTER 18-36 REFERENCE STANDARDS*
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
18-29-405.7 Design of overflows.
   Where any fixture is provided with an overflow, the waste shall be designed and installed so that standing water in the fixture will not rise in the overflow when the stopper is closed, and no water will remain in the overflow when the fixture is empty.
18-29-405.7.1 Connection of overflows.
   The overflow from any fixture shall discharge into the drainage system on the inlet or fixture side of the trap.
   Exception: The overflow from a flush tank serving a water closet or urinal shall discharge into the fixture served.
18-29-405.8 Access to concealed connections.
   Fixtures with concealed slip joint connections shall be provided with an access panel or utility space at least 12 inches (300 mm) in its smallest dimension or other approved arrangement so as to provide access to the slip connections for inspection and repair. Where such access cannot be provided, access doors shall not be required provided that all joints are soldered, solvent cemented or screwed so as to form a solid connection.
18-29-406 Automatic Clothes Washers.
18-29-406.1 Water connection.
   The water supply to an automatic clothes washer shall be protected against backflow by an air gap that is integral with the machine or a backflow preventer shall be installed in accordance with Section 18-29-608. Air gaps shall comply with ASME A112.1.2 or ASME A112.1.3.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 12)
18-29-406.2 Waste connection.
   The waste from an automatic clothes washer shall discharge through an air break into a standpipe in accordance with Section 18-29-802. The trap and fixture drain for an automatic clothes washer shall be not less than 2 inches (51 mm) in diameter. The fixture drain for the standpipe serving an automatic clothes washer shall connect to a 2-inch (51 mm) or larger diameter fixture branch or stack. Automatic clothes washers that discharge by gravity shall be permitted to drain to an approved trench drain.
   Exception: The waste from a domestic automatic clothes washer shall be allowed to discharge through an air break into a laundry sink.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 12; Amend Coun. J. 12-14-22, p. 58278, Art. VI, § 4)
18-29-406.3 Reserved.
Editor's note – Coun. J. 10-14-21, p. 37722, Art. IV, § 12, repealed § 18-29-406.3, which pertained to waste connection.
18-29-407 Bathtubs.
18-29-407.1 Approval.
   Bathtubs shall conform to ANSI Z124.1, ASME A112.19.1, ASME A112.19.4, ASME A112.19.9, CSA B45.2, CSA B45.3 or CSA B45.5.
Loading...