18-29-405.3.5 Urinal partitions.
   Each urinal utilized by the public or employees shall occupy a separate area with walls or partitions to provide privacy. The horizontal dimension between walls or partitions at each urinal shall be not less than 30 inches (762 mm). The walls or partitions shall begin at a height not greater than 12 inches (305 mm) from and extend not less than 60 inches (1524 mm) above the finished floor surface. The walls or partitions shall extend from the wall surface at each side of the urinal not less than 18 inches (457 mm) measured from the finished backwall surface or to a point not less than 6 inches (152 mm) beyond the outermost front lip of the urinal, whichever is greater.
(Added Coun. J. 10-14-21, p. 37722, Art. IV, § 11)
18-29-405.4 Floor and wall drainage connections.
   Connections between the drain and floor outlet plumbing fixtures shall be made with a floor flange. The flange shall be attached to the drain and anchored to the structure. Connections between the drain and wall-hung water closets shall be made with an approved extension nipple or horn adapter. The water closet shall be bolted to the hanger with corrosion-resistant bolts or screws. Joints shall be sealed with an approved elastomeric gasket or setting compound conforming to FS TT- P-1536a.
18-29-405.4.1 Floor flanges.
   Floor flanges for water closets or similar fixtures shall be not less than 1/8 inch (3 mm) thick for brass, 1/4 inch (6 mm) thick for plastic, and 1/4 inch (6 mm) thick and not less than a 2-inch (50 mm) caulking depth for cast-iron or galvanized malleable iron.
18-29-405.4.1.1 Hard lead floor flanges.
   Floor flanges of hard lead shall weigh not less than 1 pound 9 ounces (0.7 kg) and shall be composed of lead alloy with not less than 7.75 percent antimony by weight. Closet screws and bolts shall be of brass. Flanges shall be secured to the building structure with corrosion-resistant screws or bolts.
18-29-405.4.2 Securing floor outlet fixtures.
   Floor outlet fixtures shall be secured to the floor or floor flanges by screws or bolts of corrosion-resistant material.
18-29-405.4.3 Securing wall-hung water closet bowls.
   Wall-hung water closet bowls shall be supported by a concealed metal carrier that is attached to the building structural members so that strain is not transmitted to the closet connector or any other part of the plumbing system. The carrier shall conform to ASME A112.6.1.
18-29-405.5 Water-tight joints.
   Joints formed where fixtures come in contact with walls or floors shall be sealed with permanent caulk or other approved material.