18-29-412.4 Where required.
   The following rooms or spaces shall be provided with floor drains located to readily drain the entire floor area:
   1.   Public self-service laundries.
   2.   Shared laundry or bathing facilities in Group I or R occupancies.
   3.   Toilet facilities containing more than one water closet.
   4.   Single-user toilet rooms for public use.
   5.   Boiler rooms.
   Commercial vehicle repair garages (including repair garages serving only electric vehicles), gasoline stations with grease racks or pits, and oil change facilities shall be provided with floor drains or trench drains connected to a gas and oil interceptor in accordance with Section 18-29-1003.
   Where floor drains are installed, one floor drain shall be provided for every 500 square feet (46.5 m 2 ) of floor area.
(Amend Coun. J. 10-14-21, p. 37722, Art. IV, § 15; Amend Coun. J. 12-14-22, p. 58278, Art. VI, § 5)