184.28 SECTION R308.4.2 AMENDED- GLAZING ADJACENT TO DOORS.
Section R308.4.2, Glazing Adjacent To Doors, of the IRC, is hereby amended by deleting said section and items #1 and #2 and inserting in lieu thereof the following (exceptions remain unchanged):
Section R308.4.2 Glazing Adjacent To Doors Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge of the glazing is within a 24-inch (610 mm) arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches (1524 mm) above the walking surface shall be considered to be a hazardous location.