184.15 SECTION R110.1 AMENDED - USE AND CHANGE OF OCCUPANCY.
R110.1, Use and occupancy, of the IRC, is hereby amended by addition of the following paragraph and by deleting exception #2.
SSections R110.1 Use and Change of Occupancy Fees for all Final Occupancy Certificates shall be as set forth and established by resolution of the City Council. All such fees shall be paid in accordance with the terms and requirements of such resolution or as the same may be amended by the City Council from time to time.
184.16 SECTION R110.4 AMENDED - TEMPORARY OCCUPANCY.
R110.4, Temporary occupancy, of the IRC, is hereby amended by addition of the following paragraph:
Sections R110.4 Temporary occupancy Fees for all Temporary Occupancy Certificates shall be as set forth and established by resolution of the City Council. All such fees shall be paid in accordance with the terms and requirements of such resolution or as the same may be amended by the City Council from time to time.
184.17 SECTION R111 ADDITION - UNDERGROUND UTILITY INSTALLATION.
Section R111.4, Service Utilities, of the IRC, is hereby established by adding the following sections:
Sections R111.4 Underground utility installation All electrical service lines not exceeding four hundred eighty volts and all telephone and cablevision service lines, as well as other utility lines serving any new building or structure, including signs and billboards, requiring permanent electrical service shall be placed underground unless a waiver from such is approved by the city engineer.
The provisions of this section shall not apply to existing buildings or additions to such buildings. Nothing in this section shall be deemed to apply to temporary service when defined as such by the utility company.
184.18 SECTION R202 AMENDED - DEFINITIONS.  
Section R202 Definitions, of the IRC, is hereby amended by re-defining accessory structure and adding the definition of swimming pool and inserting in lieu thereof the following:
Section R202 Accessory Structure Accessory structures shall be defined as and shall conform to applicable zoning requirements and shall include but not be limited to structures and equipment with a fixed location on the ground, including wind energy systems, generators and equipment shelters.
Section 202 Swimming Pool Any structure intended for swimming, recreational bathing, wading, or aesthetic purposes that is capable of containing water over 24 inches deep. This includes in-ground, above-ground, and on-ground pools, hot tubs, spas, fixed-in-place wading pools, and landscape ponds, but excludes manmade lakes or ponds created through the collection of storm water or drainage runoff.
184.19 TABLE R301.2 AMENDED - CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA. 
Table R301.2, Climatic and Geographic Design Criteria, of the IRC, is hereby amended by modifying said table and adding footnote * as follows :
Table R301.2, Climatic and Geographic Design Criteria
 
Ground Snow Load
Wind Design
Seismic Design Category
Subject To Damage From
Winter
Flood Hazards
Speed MPH
Topo Effects
Special Wind
Wind Debris
Weathering
Frost Line Depth
Termite
Design Temp
Ice Barrier Req'd.
NFIP Adoption
Air Freezing Index
Mean Annual Temp.
*30 psf
115 (51)
No
No
No
A
Severe
42”
No
- 5º F
Yes
1-Feb-19
1833
48.6
See Manual J for HVAC Design Criteria
 
* minimum flat roof snow load 24 PSF
184.20 SECTION R302.1 AMENDED - EXTERIOR WALLS.
Section R302.1, Exterior walls, of the IRC, is hereby amended by deleting all exceptions and inserting in lieu thereof the following exception:
Section R302.1 Exterior walls exception #1 Accessory buildings including detached garages less than six feet (6') from a dwelling and/or less than 3 feet from a property line shall be provided with 5/8" "X" fire code sheetrock or equivalent throughout the interior, including the walls and ceiling. Any accessory structure opening(s) in wall(s) parallel to and less than six feet (6') from dwelling unit wall(s) shall be fire rated in accordance with this code.
184.21 SUBSECTION TABLE R302.1(1) AMENDED - EXTERIOR WALLS.
Table R302.1(1), Exterior Walls, of the IRC, is hereby amended by modifying said table as follows:
Exterior Wall Element
Minimum Fire-Resistance Rating
Minimum Fire Separation Distance
Walls
(Fire-resistance rated)
Dwellings - 1 hour - tested in accordance with ASTM E119, UL 263 or Section 703.3 of the International Building Code with exposure from both sides
< 5 feet
(Fire-resistance rated)
Accessory Structures - 1 hour - tested in accordance with ASTM E119, UL 263 or Section 703.3 of the International Building Code with exposure from both sides
< 3 feet
(Not fire-resistance rated)
Dwellings - 0 hours
5 feet
(Not fire-resistance rated)
Accessory Structures - 0 hours
3 feet
Projections
(Fire-resistance rated)
Dwellings - 1 hour on the underside, or heavy timber, or fire-retardant-treated wood
< 3 feet
(Fire-resistance rated)
Accessory Structures - 1 hour on the underside, or heavy timber, or fire-retardant-treated wood<2 feet
<2 feet
(Not fire-resistance rated)
Dwellings - 0 hours
3 feet
(Not fire-resistance rated)
Accessory Structures - 0 hours
2 feet
Openings
Not allowed
N/A
< 3 feet
25% Maximum Wall Area
0 hours
3 feet
Unlimited
0 hours
5 feet
Penetrations
All
Comply with Section R302.4
< 3 feet
None required
3 feet
 
184.22 R302.3 AMENDED - TWO-FAMILY DWELLINGS.
Section R302.3 Two-family dwellings, of the IRC, is hereby amended by deleting said section and exceptions and inserting in lieu thereof the following section:
R302.3 Two-family dwellings For purposes of fire-resistive separation, two-family dwelling units shall be considered as townhouse units and shall be constructed in accordance with R302.2