Skip to code content (skip section selection)
Compare to:
New York City Overview
The New York City Charter
The New York City Administrative Code
NEW YORK CITY ADMINISTRATIVE CODE
Title 1: General Provisions
Title 2: City of New York
Title 3: Elected officials
Title 4: Property of the City
Title 5: Budget; Capital Projects
Title 6: Contracts, Purchases and Franchises
Title 7: Legal Affairs
Title 8: Civil Rights
Title 9: Criminal Justice
Title 10: Public Safety
Title 11: Taxation and Finance
Title 12: Personnel and Labor
Title 13: Retirement and Pensions
Title 14: Police
Title 15: Fire Prevention and Control
Title 16: Sanitation
Title 16-A: [Commercial Waste Removal]
Title 16-B: Commercial Waste Zones
Title 17: Health
Title 18: Parks
Title 19: Transportation
Title 20: Consumer and Worker Protection
Title 20-A: [Shipboard Gambling]
Title 21: Social Services
Title 21-A: Education
Title 22: Economic Affairs
Title 23: Communications
Title 24: Environmental Protection and Utilities
Title 25: Land Use
Title 26: Housing and Buildings
Title 27: Construction and Maintenance
Title 28: New York City Construction Codes
Title 29: New York City Fire Code
Chapter 1: Enactment of the New York City Fire Code
Chapter 2: New York City Fire Code
Chapter 1: Administration
Chapter 2: Definitions
Chapter 3: General Precautions Against Fire
Chapter 4: Emergency Planning and Preparedness
Chapter 5: Fire Operations Features
Chapter 6: Building Services and Systems
Chapter 7: Fire-Resistance-Rated Construction
Chapter 8: Interior Furnishings, Decorations and Scenery
Chapter 9: Fire Protection Systems
Section FC 901: General
Section FC 902: Definitions
Section FC 903: Sprinkler Systems
Section FC 904: Fire Extinguishing Systems
904.1 General.
904.1.1 Fire extinguisher system design.
904.1.2 Installation acceptance testing.
904.1.3 Additional safeguards.
904.1.4 Prohibited fire extinguishing systems.
904.1.4.1 Existing carbon dioxide systems.
904.1.4.2 Existing halon systems.
904.1.4.3 Clean agent systems.
904.2 Where required.
904.3 Installation.
904.3.1 Electrical wiring.
904.3.2 Activation.
904.3.3 System interlocking.
904.3.4 Alarms and warning signs.
904.3.5 Monitoring.
904.3.6 Flood hazard.
904.3.7 Additional safety measures.
904.3.7.1 Carbon dioxide systems.
904.3.7.1.1 Egress precautions.
904.3.7.1.2. Ventilation and other safety equipment.
904.3.7.1.3 Detection, activation, alarm and control.
904.3.7.1.3.1 Automatic operation.
904.3.7.1.3.2 Manual operation.
904.3.7.1.3.3 Abort systems.
904.3.7.1.3.4 Power supply.
904.3.7.1.4 Pressure relief venting.
904.3.7.2 Clean agent systems.
904.3.7.2.1 System alarm and activation.
904.3.7.2.2 Warning and instruction signs.
904.3.7.2.3 Abort systems.
904.3.7.2.4 Means of egress.
904.3.7.2.5 Fixed emergency forced ventilation.
904.3.7.2.6 Pressure relief venting.
904.3.8 Commercial cooking systems.
904.3.8.1 Types of systems approved for commercial cooking operations.
904.3.8.1.1 Dry chemical, non-listed wet chemical and carbon dioxide systems.
904.3.8.2 Manual activation device.
904.3.8.3 System interconnection.
904.4 Installation inspection and testing.
904.4.1 Inspection.
904.4.2 Alarm testing.
904.5 Maintenance of fire extinguishing systems.
904.5.1 Monthly inspection.
904.5.2. Semiannual inspection.
904.5.3 Five-year retest.
904.6 Additional maintenance requirements.
904.6.1 Aerosol systems.
904.6.2 Carbon dioxide systems.
904.6.2.1 High-pressure containers.
904.6.2.2 Low-pressure containers.
904.6.2.3 System hoses.
904.6.2.3.1 Test procedure.
904.6.2.4 System components.
904.6.3 Clean agent systems.
904.6.3.1 Containers.
904.6.3.2 System hoses.
904.6.4 Dry chemical systems.
904.6.4.1. Additional maintenance requirements.
904.6.5 Foam systems.
904.6.5.1 Commercial cooking installations.
904.6.6 Halon systems.
904.6.6.1 Containers.
904.6.6.2 System hoses.
904.6.6.2.1 Test procedure.
904.6.6.3 System components.
904.6.7 Water mist systems.
904.6.8 Wet chemical systems.
904.6.8.1 Additional maintenance requirements.
904.6.8.2 Fusible link maintenance.
904.6.8.3 Commercial cooking installations.
904.6.9 Commercial cooking systems.
904.6.9.1 Fusible link and sprinkler head replacement.
904.6.10 Domestic cooking systems.
904.6.10.1 Installation.
904.6.10.2 Maintenance.
Section FC 905: Standpipe Systems
Section FC 906: Portable Fire Extinguishers
Section FC 907: Fire Alarm and Detection Systems
Section FC 908: Emergency Alarm Systems
Section FC 909: Smoke Control Systems
Section FC 910: Smoke and Heat Vents
Section FC 911: Explosion Control
Section FC 912: Fire Department Connections
Section FC 913: Fire Pumps
Section FC 914: Yard Hydrant Systems
Chapter 10: Means of Egress
Chapter 11: Reserved
Chapter 12: Reserved
Chapter 13: Reserved
Chapter 14: Reserved
Chapter 15: Reserved
Chapter 16: Reserved
Chapter 17: Reserved
Chapter 18: Reserved
Chapter 19: Reserved
Chapter 20: Aviation Facilities and Operations
Chapter 21: Dry Cleaning
Chapter 22: Combustible Dust-Producing Operations
Chapter 23: Motor Fuel-Dispensing Facilities and Repair Garages
Chapter 24: Flammable Finishes
Chapter 25: Fruit and Crop Ripening
Chapter 26: Fumigation and Insecticidal Fogging
Chapter 27: Semiconductor Fabrication Facilities
Chapter 28: Lumber Yards and Wood Waste Materials
Chapter 29: Manufacture of Organic Coatings
Chapter 30: Industrial Furnaces
Chapter 31: Tents and Other Membrane Structures
Chapter 32: High-Piled Combustible Storage
Chapter 33: Fire Safety During Construction, Alteration and Demolition
Chapter 34: Tire Rebuilding and Tire Storage
Chapter 35: Welding and Other Hot Work
Chapter 36: Marinas
Chapter 37: Combustible Fibers
Chapter 38: Reserved
Chapter 39: Reserved
Chapter 40: Distilleries
Chapter 41: Reserved
Chapter 42: Reserved
Chapter 43: Reserved
Chapter 44: Reserved
Chapter 45: Reserved
Chapter 46: Reserved
Chapter 47: Reserved
Chapter 48: Reserved
Chapter 49: Reserved
Chapter 50: Hazardous Materials - General Provisions
Chapter 51: Aerosols
Chapter 52: Reserved
Chapter 53: Compressed Gases
Chapter 54: Corrosive Materials
Chapter 55: Cryogenic Fluids
Chapter 56: Explosives, Fireworks and Special Effects
Chapter 57: Flammable and Combustible Liquids
Chapter 58: Flammable Gases
Chapter 59: Flammable Solids
Chapter 60: Highly Toxic and Toxic Materials
Chapter 61: Liquefied Petroleum Gases
Chapter 62: Organic Peroxides
Chapter 63: Oxidizers, Oxidizing Gases and Oxidizing Cryogenic Fluids
Chapter 64: Pyrophoric Materials
Chapter 65: Pyroxylin Plastics
Chapter 66: Unstable (Reactive) Materials
Chapter 67: Water-Reactive Solids and Liquids
Chapter 68: Reserved
Chapter 69: Reserved
Chapter 70: Reserved
Chapter 71: Reserved
Chapter 72: Reserved
Chapter 73: Reserved
Chapter 74: Reserved
Chapter 75: Reserved
Chapter 76: Reserved
Chapter 77: Reserved
Chapter 78: Reserved
Chapter 79: Reserved
Chapter 80: Referenced Standards
Appendix A: Fees
Appendix B: Referenced Standard Modifications
Title 30: Emergency Management
Title 31: Department of Veterans' Services
Title 32: Labor and Employment
Title 33: Investigations
Title 34: Racial Equity
Appendix A: Unconsolidated Local Laws
The Rules of the City of New York
THE RULES OF THE CITY OF NEW YORK
Title 1: Department of Buildings
Title 2: Board of Standards and Appeals
Title 3: Fire Department
Title 6: Department of Consumer and Worker Protection
Title 9: Procurement Policy Board Rules
Title 12: Franchise and Concession Review Committee
Title 15: Department of Environmental Protection
Title 16: Department of Sanitation
Title 17: Business Integrity Commission
Title 19: Department of Finance
Title 20: Tax Appeals Tribunal
Title 21: Tax Commission
Title 22: Banking Commission
Title 24: Department of Health and Mental Hygiene
Title 25: Department of Mental Health and Retardation [Repealed]
Title 28: Housing Preservation and Development
Title 29: Loft Board
Title 30: Rent Guidelines Board
Title 31: Mayor's Office of Homelessness and Single Room Occupancy
Title 34: Department of Transportation
Title 35: Taxi and Limousine Commission
Title 38: Police Department
Title 38-A: Civilian Complaint Review Board
Title 39: Department of Correction
Title 40: Board of Correction
Title 41: Department of Juvenile Justice
Title 42: Department of Probation
Title 43: Mayor
Title 44: Comptroller
Title 45: Borough Presidents
Title 46: Law Department
Title 47: Commission on Human Rights
Title 48: Office of Administrative Trials and Hearings (OATH)
Title 49: Department of Records and Information Services
Title 50: Community Assistance Unit
Title 51: City Clerk
Title 52: Campaign Finance Board*
Title 53: Conflicts of Interest Board
Title 55: Department of Citywide Administrative Services
Title 56: Department of Parks and Recreation
Title 57: Art Commission
Title 58: Department of Cultural Affairs
Title 60: Civil Service Commission
Title 61: Office of Collective Bargaining
Title 62: City Planning
Title 63: Landmarks Preservation Commission
Title 66: Department of Small Business Services
Title 67: Department of Information Technology and Telecommunications
Title 68: Human Resources Administration
Title 69: Department of Aging
Title 70: In Rem Foreclosure Release Board
Title 71: Voter Assistance Commission
Title 72: Office of Emergency Management
Title 73: Civic Engagement Commission
Title 74: Community Hiring
Loading...
904.1.2 Installation acceptance testing.
All fire extinguishing systems shall be subject to acceptance test conducted at the owner's risk by his or her representative before a representative of the department. The owner's representative shall furnish the necessary equipment required to conduct the test. A discharge test may be required as set forth in the applicable installation standard or as required by the department when there is evidence that the system will not provide the necessary level of protection.
904.1.3 Additional safeguards.
If an area is protected by a fire extinguishing system which uses an extinguishing agent that will make the protected area hazardous by its discharge or thermal decomposition, suitable safeguards shall be provided to ensure prompt evacuation, to prevent entry into such atmospheres, and to provide means for prompt rescue of any trapped personnel. Such safeguards shall include establishment of a trained brigade, equipped with and qualified in the use of self-contained breathing apparatus with 30-minute minimum supply, for prompt search of the protected area.
   Exception: Self-contained breathing apparatus shall not be required for a clean agent fire extinguishing system installation if:
      1.   The installation is provided with an alarm system that is connected to an approved central station.
      2.   The protected area is provided with an approved fixed emergency forced ventilation system able to expel the extinguishing agent. Such emergency forced ventilation system shall have a capacity sufficient to effect at least twenty air changes per hour.
      3.   The protected area is of a size, design and/or occupied in such a manner that egress will not be impeded.
      4.   The protected area is not normally occupied by any individual requiring assistance in evacuation.
904.1.4 Prohibited fire extinguishing systems.
It shall be unlawful to install carbon dioxide, halon and clean agent fire extinguishing systems as set forth in FC 904.1.4.1 through 904.1.4.3.
Loading...