Skip to code content (skip section selection)
Compare to:
Cleveland Overview
Cleveland, OH Code of Ordinances
CITY OF CLEVELAND, OHIO CODE OF ORDINANCES
CHARTER OF THE CITY OF CLEVELAND
PART ONE: ADMINISTRATIVE CODE
PART TWO: HEALTH CODE
PART THREE: LAND USE CODE
PART FOUR: TRAFFIC CODE
PART FIVE: MUNICIPAL UTILITIES AND SERVICES CODE
TITLE I: STREET AND SIDEWALK AREAS
TITLE III: ELECTRICITY
TITLE V: WATER SUPPLY
CHAPTER 531 - WATER AND FIRE SERVICE CONNECTIONS
§ 531.01 Service Line Installations, Connections and Taps by the Division of Water and Authorized Contractors
§ 531.02 Application for Installation of Service Connection
§ 531.03 Charges for Installation of Service Connections, Tapping Sleeves and Valves
§ 531.04 Lead Required for Tapping Sleeves and Valves - Repealed
§ 531.05 Service Connection Extension and Inspection
§ 531.06 Charge for Service Pipe beyond Curb
§ 531.07 Abandoned Service Connections
§ 531.08 Provisions for Additional Supply to Premises
§ 531.09 Size of Service Connections
§ 531.10 Tapping Mains with 16-inch Inside Diameter
§ 531.11 Material for Service Pipes
§ 531.12 Standard Weight of Lead Pipe - Repealed
§ 531.13 Standard Dimensions and Weight of Copper Pipe
§ 531.14 Length of Copper Pipe
§ 531.15 Depth of Service Pipe
§ 531.16 Service Pipe Not to be Laid in Sewer Trench
§ 531.17 Backfilling Regulations
§ 531.18 Regulations for Stop Cocks or Valves and Boxes
§ 531.19 Temporary Service Connections; Deposit
§ 531.20 Extension on Stop Cocks
§ 531.21 Stop Cock or Valve Boxes in Flagging or Pavements
§ 531.22 Regulations for Compression Stop and Waste Cocks and Valves; Space for Meter
§ 531.23 Backflow Prevention Control Device Required
§ 531.24 Qualification and Certification of Persons to Inspect and Maintain Backflow Prevention Devices
§ 531.25 Two or More Services for One Premises; Connecting Pipe Specifications
§ 531.26 Applications or Changes in Fire Service Connections
§ 531.27 Plans and Information to be Furnished for Fire Service Connections
§ 531.28 Fire Service System to Comply with City’s Standards
§ 531.29 Fire Service Pipe Use Restricted
§ 531.30 Size of Fire Protection Connections
§ 531.31 Location of Fire Service Connection Restricted
§ 531.32 Check Valves for Sprinkler System Pipes
§ 531.33 Tanks for Fire Purposes to Have Metered Supply Pipe
§ 531.34 Overflow Pipe
§ 531.35 Tank Supply Pipes
§ 531.36 Drip or Blow-Off Pipes
§ 531.37 Pumps for Fire Protection
§ 531.38 Outlet Valves to be Sealed
§ 531.39 No Connection Allowed Between Different Pressure Service Systems
§ 531.40 Fire Service Pipes to be Accessible for Inspection
§ 531.41 Use of Fire Service Water
§ 531.42 Use of System by Division of Fire
§ 531.43 Permit for Extension of Fire Service Connections
§ 531.44 Plumber to Turn Water Off after Construction
§ 531.45 Approval of Permit for Building Demolition
§ 531.46 Permit and Written Return for Plumbing Work
§ 531.47 Permit to Open Street, Lane or Alley
§ 531.48 Permission to Let Water on Premises
§ 531.49 Monthly Return
§ 531.50 Persons Authorized to Make Connections - Repealed
§ 531.51 Location of Service Pipes
§ 531.52 Location of Boxes and Fixtures
§ 531.53 Responsibility for Service Pipe Upkeep
§ 531.54 Regulations for Connecting Two or More Service Pipes
§ 531.55 Service Pipes Supplying Elevators or Large Motors
§ 531.56 Inspection, Approval and Repair of Fixtures
§ 531.57 Reserved
§ 531.58 Connecting High and Low Service Systems Prohibited
§ 531.59 Changing Fire Pipe System; Permit
§ 531.60 Inspection of Fire Pipes
§ 531.61 Permit for Special Use of Hydrants
§ 531.62 Responsibility for Violations
§ 531.63 Revocation of License
§ 531.64 Interfering with Fire System
§ 531.65 Removing Covers, Valves, etc. from Cisterns or Hydrants
§ 531.66 Waste in Reservoirs; Bathing; Walking or Riding on Turf
§ 531.67 Fouling or Tampering with Hydrants and Waters Fixtures
§ 531.68 Obstructing Use of Water System Apparatus
§ 531.69 Turning Valves on Stop Cocks
§ 531.70 Obstructing Hydrants, Valves, etc.
§ 531.71 Air Chambers for Motor Pipes
§ 531.72 Water Supply from Other Sources Not to be Connected with City Water Supply
§ 531.73 Repairs to Damaged Fire System Property; Costs
§ 531.74 Procedure and Costs for Moving Hydrants, etc.
§ 531.75 Access to Premises Where Water Is Supplied
§ 531.76 Conditions When Water Shut off Without Notice
§ 531.77 Refusal or Neglect to Pay for Service Connections or Repairs; Fee
§ 531.78 Conditions When Connections May be Plugged; Fee
§ 531.79 Additional Rules and Regulations
§ 531.81 Fees for Engineering Services
§ 531.99 Penalty
CHAPTER 533 - WATER METERS
CHAPTER 535 - WATER RATES AND BILLINGS
TITLE VII: SEWERS AND SEWAGE DISPOSAL
TITLE IX: MUNICIPAL SERVICES
TITLE XI: PORT CONTROL
PART SIX: OFFENSES AND BUSINESS ACTIVITIES CODE
TITLE VIIA: CLEVELAND NEIGHBORHOOD FORM-BASED CODE
Loading...
§ 531.45 Approval of Permit for Building Demolition
   Before a permit for tearing down or removing a building from any premises within the metropolitan area shall be given by the Commissioner of Building, or officer in charge of such permits in the various municipalities or other political subdivisions of the metropolitan area, the application for such permit must have the approval of the Commissioner of Water.
(Ord. No. 99566. Passed 5-22-33)
§ 531.46 Permit and Written Return for Plumbing Work
   No plumber shall make any attachments, additions to or alterations in any service pipe cock or other fixture connected with the service water pipes, unless he or she first procures a permit from the Commissioner of Water for such work, and makes a written return of the same as prescribed in these rules and regulations.
§ 531.47 Permit to Open Street, Lane or Alley
   Before permits for extending connections are issued, the plumber must present a permit from the Director of Public Service authorizing him or her to open the street, lane or alley in which connection is to be made. No licensed plumber will be granted a permit for work to be done by a person not in the employ of such plumber.
§ 531.48 Permission to Let Water on Premises
   No plumber after making any connection with the service pipes, or after making repairs or putting in any new attachment, shall leave the stop cock open, or let the water on the premises without permission from the Director of Public Utilities.
§ 531.49 Monthly Return
   Not later than the fifth of each month, all licensed plumbers shall make a true return in writing on blanks furnished at the office of the Division of Water, of all work, authorized by permit of the Commissioner of Water, completed during the previous calendar month, or if no such work has been completed, the return shall be made bearing a statement to that effect.
§ 531.50 Persons Authorized to Make Connections – Repealed
(Ord. No. 246-06. Passed 4-10-06, eff. 4-13-06)
§ 531.51 Location of Service Pipes
   Service pipes between the main and the street line shall be laid not less than six (6) feet below the surface of the street, and between the street line and the building shall not be less than five and one-half (5-1/2) feet below the surface of the ground.
Loading...