Subdivision 303 – Assembly
13-84-010 General requirements.
13-84-020 Capacity of schools.
13-84-030 Frontage requirements.
13-84-040 Special height limitations.
13-84-050 Special enclosures and separations.
13-84-060 Special fire-resistive requirements.
13-84-070 Definitions.
13-84-080 Construction requirements – Type 1 stages.
13-84-090 Construction requirements – Type 2 stages.
13-84-100 Stage vents – Type 1 stages.
13-84-110 Proscenium opening – Type 1 stages.
13-84-120 Projection rooms.
13-84-130 Bowling alleys.
13-84-140 Planning requirements for Type I schools.
13-84-150 Planning requirements for Type III schools.
13-84-160 Special exit requirements.
13-84-170 Minimum number of exits.
13-84-180 Width of exits.
13-84-190 Location of exits.
13-84-200 Exit connections.
13-84-210 Exit courts and exit passageways.
13-84-220 Waiting spaces.
13-84-230 Aisles and seating.
13-84-240 Railings.
13-84-250 Ramps and steps.
13-84-260 Exits from stage block.
13-84-270 Fixed seating.
13-84-280 Schools for handicapped children – Elevator requirements.
13-84-290 Accessibility for handicapped.
13-84-300 Exhibition areas in excess of 10,000 square feet.
13-84-310 Automatic smoke and heat vents – Requirements for topmost occupied levels.
13-84-320 Noncombustible draft curtains – Where required.
13-84-330 Automatic smoke and heat vents – Requirements for lower floor levels.
13-84-331 Special requirement for nightclubs and restaurants.
13-84-340 Exhibition area minimum aisle width.
13-84-350 Smoke detectors.
13-84-351 Temporary display booths.
13-84-360 Storage of combustible containers.
13-84-370 Open plan schools – Individual plan floor areas.
13-84-380 Stair enclosures.
13-84-390 Fire guard requirements.
13-84-400 Floor plan diagram to be submitted to department of buildings.
13-84-410 Building capacity – Signs to be posted.
13-84-420 Building capacity – Approval required.
13-84-430 Exit and aisle regulations.
Every building or part of a building hereafter designed, erected, altered or converted for the purposes of an assembly unit as defined in Section 13-56-070 shall comply with the special provisions of this chapter and also with the general provisions of this Code pertaining to buildings, including, but not limited to, the following:
Chapter 13-56 Classifications of Buildings by Occupancy.
Section 13-56-230 Mixed occupancy.
Section 13-56-300 Occupancy content.
Chapter 13-60 Classification of Buildings by Construction Type.
Chapter 13-116 Fire Limits – Location Limitations.
Sections 13-116-040 and 13-116-050 Location on property.
Sections 13-116-080 to 13-116-130 Inclusive. Limitations within fire limits.
Chapter 13-48 Height and Area Limitations.
Section 13-48-010 Height limitations.
Section 13-48-050 Area limitations.
Section 13-48-100 Mixed occupancy.
Chapter 15-8 Fire-Resistive Requirements.
Section 15-8-010 Fire walls.
Section 15-8-070 Exterior walls.
Section 15-8-250 Partitions.
Section 15-8-280 Exterior trim.
Section 15-8-330 Roof coverings.
Section 15-8-370 Interior wall and ceiling finish and trim.
Section 15-8-450 Flooring.
Section 15-8-510 Roof structures.
Section 15-8-570 Firestopping.
Chapter 18-28 Chimneys, Flues and Vents.
Chapter 15-16 Fire Protection Equipment.
Chapter 15-12 Fire-Resistive Materials and Construction.
Chapter 13-160 Exit Requirements.
Section 13-160-030 Types of exits.
Section 13-160-050 Minimum number of exits.
Section 13-160-060 Arrangement and location of exits.
Section 13-160-110 Travel distance to exits.
Section 13-160-170 Width of exits.
Section 13-160-230 Outside exits.
Section 13-160-240 Doors.
Section 13-160-290 Stairways.
Section 13-160-360 Smokeproof towers.
Section 13-160-430 Ramps.
Section 13-160-480 Horizontal exits.
Section 13-160-580 Exterior stairs.
Section 13-160-630 Fire escapes.
Section 13-160-660 Exit lighting.
Section 13-160-700 Exit signs.
Chapter 13-52 Minimum Design Loads.
Chapter 13-120 Materials, Methods and Tests.
Chapter 13-132 Foundations.
Chapter 13-140 Masonry Construction.
Chapter 13-144 Wood Construction.
Chapter 13-136 Concrete Construction.
Chapter 13-148 Steel and Metal Construction.
Chapter 13-124 Safety Requirements.
Chapter 13-124 Safeguards During Construction.
Chapter 13-128 Use of Public Property.
Chapter 13-196 Existing Buildings.
Chapter 18-28 Heating.
Chapter 18-28 Ventilation.
Chapter 13-172 Light And Ventilation.
Chapter 18-29 Plumbing.
Chapter 18-29 Sanitation Requirements.
Title 14C Conveyance Devices.
Title 14E Electrical Requirements.
(Prior code § 54-1; Amend Coun. J. 6-14-95, p. 2841; Amend Coun. J. 4-29-98, p. 66679, § 2; Amend Coun. J. 10-17-09, p. 72419, § 15; Amend Coun. J. 11-9-16, p. 36266, § 18; Amend Coun. J. 9-6-17, p. 55278, Art. II, § 26; Amend Coun. J. 3-28-18, p. 74459, Art. II, § 12)
The total capacity of a school shall be determined in accordance with the occupancy content factors established in Section 13-56-310, except that rooms not used or used only occasionally by students shall not be included in computing each total capacity. Such rooms and spaces include the following:
Assembly rooms and gymnasiums;
Cafeterias and lunchrooms;
Locker, toilet and storage rooms;
Corridors and other circulation space;
Service and equipment rooms.
(Prior code § 54-2)