BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
Subdivision 302 - Classification
Subdivision 303 - Assembly
CHAPTER 13-84 ASSEMBLY UNITS
13-84-010 General requirements.
13-84-020 Capacity of schools.
13-84-030 Frontage requirements.
13-84-040 Special height limitations.
13-84-050 Special enclosures and separations.
13-84-060 Special fire-resistive requirements.
13-84-070 Definitions.
13-84-080 Construction requirements - Type 1 stages.
13-84-090 Construction requirements - Type 2 stages.
13-84-100 Stage vents - Type 1 stages.
13-84-110 Proscenium opening - Type 1 stages.
13-84-120 Projection rooms.
13-84-130 Bowling alleys.
13-84-140 Planning requirements for Type I schools.
13-84-150 Planning requirements for Type III schools.
13-84-160 Special exit requirements.
13-84-170 Minimum number of exits.
13-84-180 Width of exits.
13-84-190 Location of exits.
13-84-200 Exit connections.
13-84-210 Exit courts and exit passageways.
13-84-220 Waiting spaces.
13-84-230 Aisles and seating.
13-84-240 Railings.
13-84-250 Ramps and steps.
13-84-260 Exits from stage block.
13-84-270 Fixed seating.
13-84-280 Schools for handicapped children - Elevator requirements.
13-84-290 Accessibility for handicapped.
13-84-300 Exhibition areas in excess of 10,000 square feet.
13-84-310 Automatic smoke and heat vents - Requirements for topmost occupied levels.
13-84-320 Noncombustible draft curtains - Where required.
13-84-330 Automatic smoke and heat vents - Requirements for lower floor levels.
13-84-331 Special requirement for nightclubs and restaurants.
13-84-340 Exhibition area minimum aisle width.
13-84-350 Smoke detectors.
13-84-351 Temporary display booths.
13-84-360 Storage of combustible containers.
13-84-370 Open plan schools - Individual plan floor areas.
13-84-380 Stair enclosures.
13-84-390 Fire guard requirements.
13-84-400 Floor plan diagram to be submitted to department of buildings.
13-84-410 Building capacity - Signs to be posted.
13-84-420 Building capacity - Approval required.
13-84-430 Exit and aisle regulations.
CHAPTER 13-88 OPEN AIR ASSEMBLY UNITS
Subdivision 304 - Business
Subdivision 306 - Factory
Subdivision 307 - High-Hazard
Subdivision 308 - Institutional
Subdivision 309 - Mercantile
Subdivision 310 - Residential
Subdivision 311 - Storage
Subdivision 312 - Utility and Miscellaneous
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
13-84-330  Automatic smoke and heat vents – Requirements for lower floor levels.
   Exhibition areas on lower floor levels shall be provided with automatic smoke and heat venting at a rate of two cfm per square foot measured at 70 degrees Fahrenheit. Fans for this purpose are to be wired to an emergency power supply and operated by smoke detectors. All smoke detectors shall be approved by Underwriters Laboratories and the fire commissioner.
(Prior code § 54-9.3; Amend Coun. J. 5-18-16, p. 24131, § 41)
13-84-331  Special requirement for nightclubs and restaurants.
   Every newly constructed, reconstructed or substantially rehabilitated nightclub or restaurant with an occupancy of more than 100 persons and located in whole or in part more than four feet below street grade shall be equipped with an approved automatic sprinkler system. Every existing nightclub or restaurant with an occupancy of more than 100 persons and located in whole or in part more than four feet below street grade shall be equipped with an approved automatic sprinkler system within six months after the effective date of this section.
(Added Coun. J. 11-1-00, p. 43076, § 2)
13-84-340  Exhibition area minimum aisle width.
   Minimum width of aisles in exhibition areas shall be eight feet.
(Prior code § 54-9.4)
13-84-350  Smoke detectors.
   All mechanical equipment used in supplying or recirculating air in an exhibition area shall be automatically stopped by smoke detectors. Smoke detectors shall be approved as required in Section 13-84-330 of this Code.
(Prior code § 54-9.5)
13-84-351  Temporary display booths.
   All temporary booths erected within assembly units shall comply with the following minimum requirements:
   a.   One approved battery-operated smoke alarm for each 1,000 square feet of enclosed area; and
   b.   One approved fire extinguisher for each 1,000 square feet of enclosed area.
(Added Coun. J. 9-15-93, p. 37767; Amend Coun. J. 9-6-17, p. 55278, Art. VI, § 23)
13-84-360  Storage of combustible containers.
   Areas used for storage of combustible containers in new and existing buildings with exhibition areas shall be enclosed with two-hour fire-resistive construction and shall have a standard sprinkler system as defined in Chapter 15-16 of this Code.
(Prior code § 54-10)
13-84-370  Open plan schools – Individual plan floor areas.
   In open plan schools, individual open plan floor areas shall be limited to an area not exceeding 30,000 square feet and a maximum linear dimension of 300 feet, unless an approved automatic sprinkler system, as defined in Chapter 15-16 of this Code, is installed throughout the building. Separation of individual open plan areas shall be achieved by the provision of smoke- stop barriers constructed of noncombustible materials having fire resistant properties not less than that of one- fourth inch thick wired glass installed in steel sash and frames. Doors provided therein shall be not less fire resistant than the barriers on which they are installed, shall close the opening completely with only such clearance as is necessary for proper operation, and shall be equipped with approved self-closing devices. Whenever such doors must be maintained open, approved electro-magnetic hold open devices shall be provided, arranged to close the doors automatically when activated by the building's fire alarm system or by specially installed approved smoke detectors located above such door openings.
(Prior code § 54-11)
13-84-380  Stair enclosures.
   Required stair enclosures shall comply with the requirements of Section 15-8-140. All other vertical openings shall be enclosed by smoke-tight partitions having a standard fire resistance of one hour except that vertical openings may remain unprotected in two story high spaces in open plan schools if an approved automatic sprinkler system, as defined in Chapter 15-16 of this Code, is installed throughout the building.
(Prior code § 54-12)
13-84-390  Fire guard requirements.
   For fire guard requirements, see Chapter 15-4 of this Code.
(Prior code § 54-13)
13-84-400  Floor plan diagram to be submitted to department of buildings.
   The owner, lessee or person in charge of every theater, public assembly unit or open air assembly unit shall submit to the department of buildings a diagram indicating the arrangement and number of tables, chairs or seats, and dimensions of dancing space, stages, platforms, aisles and means of exit.
   The diagram shall also show the amount and type of scenery permitted on the stage or platform, if there be a stage or platform, and the total yardage of decorations permitted to hang in the audience room or hall. One copy of such diagram, which has been approved by the department of buildings, shall be kept on the premises for which the approval has been granted and shall be conspicuously displayed.
(Prior code § 54-14; Amend Coun. J. 9-13-89, p. 4604; Amend Coun. J. 3-5-03, p. 104990, § 23; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1)