You are viewing an archived code
Subdivision 307 – High-Hazard
Article I. General Provisions
13-112-010 General requirements.
13-112-020 Special requirements.
13-112-030 Fire protection requirements.
13-112-040 Types of occupancies.
13-112-050 Classification of occupancies.
13-112-060 Hazardous use rooms.
Article II. Buildings of Mixed Occupancies
13-112-070 General requirements.
13-112-080 Auxiliary business use.
13-112-090 Fire resistive separation.
13-112-100 Communicating openings.
13-112-110 Courts.
Article III. Rooms and Floor Areas
13-112-120 General requirements.
13-112-130 Floor areas.
13-112-140 Rooms prohibited in basements.
13-112-150 Lot occupancy.
13-112-160 Court requirements.
13-112-170 Ventilation.
13-112-180 Fire doors.
13-112-190 Equipment.
13-112-200 Conveyors and ducts.
13-112-210 Heating.
13-112-220 Heat piping.
13-112-230 Licenses, certificates of fitness, permits and bonds.
Article IV. Means of Exit
13-112-240 General requirements.
13-112-250 Exits near openings.
13-112-260 Distance to exits.
13-112-270 Number of exits.
13-112-280 Vertical means of exit.
13-112-290 Dry cleaning building.
13-112-300 Film examining or repairing rooms.
13-112-310 Motion picture trial exhibition rooms.
Article V. Artificial Lighting and Exit Signs
13-112-320 General requirements.
13-112-330 Artificial lighting.
13-112-340 Exit signs.
13-112-350 Exit directional signs.
ARTICLE I. GENERAL PROVISIONS (13-112-010 et seq.)
Every building, structure or tank, part of a building, hereafter designed, erected, altered or converted for the purposes of a hazardous use unit, as defined in Section 13-56-210, shall comply with the building provisions of this Code, including, but not limited to, the following:
Chapter 13-56 Classification of Buildings by Occupancy.
Section 13-56-230 Mixed occupancy.
Section 13-56-300 Occupancy content.
Chapter 13-60 Classification of Buildings by Construction Type.
Chapter 13-116 Fire Limits – Location Limitations.
Sections 13-116-040 and 13-116-050 Location on property.
Sections 13-116-080 to 13-116-130 Inclusive. Limitations within fire limits.
Chapter 13-48 Height and Area Limitations.
Section 13-48-010 Height limitations.
Section 13-48-050 Area limitations.
Section 13-48-100 Mixed occupancy.
Chapter 15-8 Fire-Resistive Requirements.
Section 15-8-010 Fire walls.
Section 15-8-070 Exterior walls.
Section 15-8-250 Partitions.
Section 15-8-280 Exterior trim.
Section 15-8-330 Roof coverings.
Section 15-8-370 Interior wall and ceiling finish and trim.
Section 15-8-450 Flooring.
Section 15-8-510 Roof structures.
Section 15-8-570 Firestopping.
Chapter 18-28 Chimneys, Flues and Vents.
Chapter 15-16 Fire Protection Equipment.
Chapter 15-12 Fire-Resistive Materials and Construction.
Chapter 13-172 Light And Ventilation.
Chapter 13-160 Exit Requirements.
Section 13-160-030 Types of exits.
Section 13-160-050 Minimum number of exits.
Section 13-160-060 Arrangement and location of exits.
Section 13-160-110 Travel distance to exits.
Section 13-160-170 Width of exits.
Section 13-160-230 Outside exits.
Section 13-160-240 Doors.
Section 13-160-290 Stairways.
Section 13-160-360 Smokeproof towers.
Section 13-160-430 Ramps.
Section 13-160-480 Horizontal exits.
Section 13-160-520 Escalators.
Section 13-160-580 Exterior stairs.
Section 13-160-630 Fire escapes.
Section 13-160-660 Exit lighting.
Section 13-160-700 Exit signs.
Chapter 13-52 Minimum Design Loads.
Chapter 13-120 Materials, Methods and Tests.
Chapter 13-132 Foundations.
Chapter 13-140 Masonry Construction.
Chapter 13-144 Wood Construction.
Chapter 13-136 Concrete Construction.
Chapter 13-148 Steel and Metal Construction.
Chapter 13-124 Safety Requirements.
Chapter 13-124 Safeguards During Construction.
Chapter 13-128 Use of Public Property.
Chapter 13-196 Existing Buildings.
Chapter 18-28 Heating.
Chapter 18-28 Ventilation.
Chapter 18-29 Plumbing.
Chapter 18-29 Sanitation Requirements.
Title 14C Conveyance Devices.
Title 14E Electrical Requirements.
Chapter 15-16 Fire Protection Equipment.
Chapter 15-28 Hazardous Materials and Combustible Solids.
Chapter 15-26 Fume and Flammable Compressed Gases.
Chapter 15-24 Flammable Liquids.
(Prior code § 60-1; Amend Coun. J. 6-14-95, p. 2841; Amend Coun. J. 4-29-98, p. 66679, § 2; Amend Coun. J. 11-9-16, p. 36266, § 24; Amend Coun. J. 9-6-17, p. 55278, Art. II, § 40; Amend Coun. J. 3-28-18, p. 74459, Art. II, § 17)
Every building, part of a building, structure or tank, hereafter designed, erected, altered or converted for the purposes of hazardous use unit shall comply with the general provisions in this Code and in addition shall comply with the special provisions of Chapters 15-4, 15-16, 15-20, 15-24, 15-26 and 15-28. The requirements of this Code shall apply to any hazardous use units used for industrial or storage purposes, except as otherwise provided in the above-mentioned chapters. Every existing building, structure or tank having an occupancy which would be classed as a hazardous use unit by the building provisions of this Code shall be so classified with respect to any additions, increase in capacity, or alteration thereof, and shall conform to the provisions of the above-mentioned chapters and of Chapter 13-196.
(Prior code § 60-2; Amend Coun. J. 6-14-95, p. 2841; Amend Coun. J. 11-9-16, p. 36266, § 24)
Loading...