Except as provided in Section 13-48-040, no building shall be hereafter erected to exceed the maximum allowable heights established in Table 13-48-030 of this Code. School height limitations are not applicable to Type III schools in buildings of mixed occupancies in construction Type III or better. Type III schools shall not be permitted in buildings of Type IV- A or Type IV-B construction. Intermediate care facilities for the developmentally disabled – 15 or less shall not be permitted in any building of Type IV-A or Type IV-B construction. (See Table 13-48-030.)
Notwithstanding the provisions of this section, the height limitation for a building in the Wrigley Field Adjacent Area in which a special club license is located shall be as provided in Chapter 4-388.
Occupancy Classification | Construction Type | ||||||||||
I-A | I-B | I-C | II | III-A | III-B | III-C | IV-A | IV-B | |||
A. | Residential | Stories | NL | 12 | 6 | 1 | 4(d) | 4 | 2(a)(h) | 2(a)(g)(h) | 2(a) |
Feet | NL | 150 | 80 | 20 | 55(d) | 55 | 40f | 40f | 30 | ||
B. | Institutional | Stories | NL | 10 | 4 | 1 | 1 | 1 | NP | NP | NP |
Feet | NL | 130 | 55 | 20 | 20 | 20 | – | – | – | ||
C-1. | Large | Stories | NL | 8 | 2 | NP | 2(b) | 2 | NP | NP | NP |
Assembly | Feet | NL | 105 | 50 | – | 50(b) | 50 | – | – | – | |
C-2. | Small | Stories | NL | 10 | 4 | 1 | 2(b) | 2 | 1 | 1 | 1 |
Assembly | Feet | NL | 130 | 55 | 30 | 50(b) | 50 | 30 | 30 | 30 | |
C-3. | Schools | Stories | NL | 10 | 4 | 1 | 2 | 2 | 1 | 1 | 1 |
Feet | NL | 130 | 55 | 20 | 30 | 30 | 20 | 20 | 20 | ||
D. | Open Air Assembly | Maximum height established in Chapter 55 | |||||||||
E. | Business | Stories | NL | 12 | 6(b) | 1 | 5(b) | 4 | 3 | 1 | 1 |
Feet | NL | 150 | 80(b) | 20 | 65(b) | 55 | 45 | 20 | 20 | ||
F. | Mercantile | Stories | NL | 8 | 4 | 1 | 5(b) | 3 | 2 | 1 | 1 |
Feet | NL | 105 | 80 | 20 | 65(b) | 45 | 30 | 20 | 20 | ||
G-1. | Industrial | Stories | NL | 12 | 6(b) | 2 | 5(b) | 4 | 3 | 1 | 1 |
Low | Feet | NL | 150 | 80(b) | 40 | 65(b) | 55 | 45 | 30 | 30 | |
G-2. | Industrial | Stories | 8(c) | 5(b) | 4(b) | 1 | 5(b) | 4 | 2(b) | 1 | 1 |
Moderate | Feet | 105(c) | 65(b) | 55(b) | 40 | 65(b) | 55 | 30(b) | 30 | 30 | |
Hazard | |||||||||||
H-1. | Storage | Stories | NL | 12 | 6(b) | 2 | 5(b) | 4 | 3 | 1 | 1 |
Low Hazard | Feet | NL | 150 | 80(b) | 40 | 65(b) | 55 | 45 | 30 | 30 | |
H-2. | Storage | Stories | 8(c) | 5(b) | 4(b) | 1 | 5(b) | 3(b) | 2(b) | 1 | 1 |
Moderate | Feet | 105(c) | 65(b) | 55(b) | 40 | 65(b) | 45(b) | 30(b) | 30 | 30 | |
Hazard | |||||||||||
H-3. | Garages | Stories | 4(c) | 3 | 3 | 1 | 2 | 2 | 1 | NP | NP |
Feet | 55(c) | 40 | 40 | 20 | 30 | 30 | 20 | – | – | ||
I. | Hazardous Use | Maximum allowable heights established in Chapter 60 | |||||||||
J. | Miscellaneous Buildings and Structures | Maximum allowable heights established in Chapter 61 | |||||||||
K. | Intermediate care facilities for develop- mentally disabled – 15 or less(e) | Stories | 2 | 2 | 2 | 2 | 2 | 2 | 2 | NP | NP |
Feet | 30 | 30 | 30 | 30 | 30 | 30 | 30 | NP | NP | ||
NOTES: | |||||||||||
(a) Attic floor exceeding 30 feet above grade allowed in addition when used for mechanical equipment only, but shall not exceed 20 percent of floor area below. | |||||||||||
(b) One additional story and 15 feet additional height allowed when the building is equipped throughout with approved automatic sprinkler system. | |||||||||||
(c) Height shall not be limited when building is equipped throughout with approved automatic sprinkler system. | |||||||||||
(d) In an existing heavy timber building the height may be increased to 120 feet, 80 feet for new buildings, regardless of the number of stories when the building is brought into full compliance with the following: | |||||||||||
(1) Chapter 13-76;
| |||||||||||
(3) “Controlled Materials”, Section 13-120-040; | |||||||||||
(4) In existing buildings over 80 feet in height, an automatic general alarm shall be installed and be audible throughout the corridors of the building and shall be activated by the sprinkler flow alarm and smoke detectors. | |||||||||||
(e) For purposes of defining a story in this occupancy, any level above or below the first floor used by the residents, for any purpose other than personal laundry, shall be deemed a story. | |||||||||||
(f) The finished floor level of the third floor shall not exceed 25 feet above grade. | |||||||||||
(g) Mechanical equipment areas shall be equipped with smoke detector connected to electrical system, when building exceeds 30 feet in height and mechanical equipment is located in area above 30 feet. | |||||||||||
(h) Other requirements notwithstanding, three floors shall be permitted in one-, two-, and three-family structures when exterior wood frame walls provide one hour protection from fire exposure inside and out, when the third floor area of any separate unit does not exceed 800 square feet and when the ground floor area does not exceed 1,600 square feet. | |||||||||||
NP – Not permitted. | |||||||||||
NL – Not limited. | |||||||||||
(Prior code § 51-1.2; Amend Coun. J. 12-21-84, p. 12140; Corrected. 4-20-88, p. 12481; Amend Coun. J. 3-30-88, p. 11381; Amend Coun. J. 11-29-89, p. 8272; Amend Coun. J. 10-2-95, p. 8040; Amend Coun. J. 1-11-06, p. 68371, § 3; Amend Coun. J. 9-6-17, p. 55278, Art. VI, § 7)
(a) Towers, steeples and similar structures, not intended or used for human occupancy and not exceeding in area 25 percent of the ground area of the building on which they are erected, may be erected to a height not exceeding 60 feet above the height limitations established in Section 13-48-030, except that water tanks or towers for fire protection purposes, whether supported directly on buildings or on independent ground structures, may be erected to a height not exceeding 60 feet above the maximum height of the building or group of buildings which is served or protected by such water tanks; provided that the height limitation of such structures constructed on a building in the Wrigley Field Adjacent Area in which special club license is located shall be as provided in Chapter 4-388.
(Prior code § 51-1.3; Amend Coun. J. 1-11-06, p. 68371, § 3)
(a) The maximum floor area of buildings shall be governed by the occupancy classification, the number of stories and the type of construction as required in this section.
(b) Nothing in this section shall be interpreted to prevent the application of other area restrictions required by the Chicago Zoning Ordinance.
(c) In the application of area limitations, each part of a building separated from all other parts of the building by fire walls as defined in Section 15-8-020 shall be deemed to be a separate building.
(d) The area of a basement shall not exceed the maximum floor area permitted for the building; provided, however, that every basement exceeding 40,000 square feet in area shall be subdivided by fire walls complying with the requirements of Section 15-8-010 into areas not exceeding 40,000 square feet. The maximum undivided area of a basement may be increased to 80,000 square feet when the building is equipped throughout with an approved automatic sprinkler system in accordance with Chapter 15-16 of the municipal code.
(Prior code § 51-2.4; Amend Coun. J. 2-13-85, p. 13526)
(Prior code § 51-2.2)
Occupancy Classification | Construction Type | |||||||||
I-A | I-B | I-C | II | III-A | III-B | III-C | IV-A | IV-B |
Occupancy Classification | Construction Type | |||||||||
I-A | I-B | I-C | II | III-A | III-B | III-C | IV-A | IV-B | ||
A. | Residential | NL | NL | 24,000 | 10,000 | 10,000 | 10,000 | 8,000 | 5,000 | 3,000 |
B. | Institutional | NL | NL | 16,000 | 6,000 | 6,000 | 6,000 | NP | NP | NP |
C-1. | Large | NL | NL | NL(a) | 20,000(a) | 25,000(a) | 20,000(a) | NP | NP | NP |
Assembly | 24,000 | 8,000 | 10,000 | 8,000 | ||||||
C-2. | Small Assembly | NL | NL | NL(a) | 20,000(a) | 20,000(a) | 20,000(a) | NP(b) | NP(b) | NP(b) |
24,000 | 8,000 | 10,000 | 8,000 | 5,000(c) | 3,000(c) | 1,500(c) | ||||
C-3. | Schools | NL | NL | NL(a) | 20,000(a) | 25,000(a) | 20,000(a) | |||
24,000 | 8,000 | 10,000 | 8,000 | 6,000 | 4,000 | 2,000 | ||||
D. | Open Air Assembly | Maximum areas established in Chapter 13-88 | ||||||||
E. | Business | NL | NL | NL | NL(a)(d) | NL(a)(d) | NL(a)(d) | 10,000 | 6,000 | 4,000 |
12,000 | 15,000 | 12,000 | ||||||||
F. | Mercantile | NL | NL | NL | NL(a)(d) | NL(a)(d) | NL(a)(d) | 8,000 | 5,000 | 3,000 |
10,000 | 12,000 | 10,000 | ||||||||
G-1. | Industrial | NL | NL | NL | NL(a) | NL(a) | NL(a) | 10,000 | 6,000 | 4,000 |
Low Hazard | 12,000 | 15,000 | 12,000 | |||||||
G-2. | Industrial | NL | NL | NL | NL(a)(d) | NL(a)(d) | NL(a)(d) | 8,000 | 5,000 | 3,000 |
Moderate Hazard | 10,000 | 12,000 | 10,000 | |||||||
H-1. | Storage | NL | NL | NL | NL(a) | NL(a) | NL(a) | 10,000 | 6,000 | 4,000 |
Low Hazard | 12,000 | 15,000 | 12,000 | |||||||
H-2. | Storage | NL | NL | NL | NL(a)(d) | NL(a)(d) | NL(a)(d) | 8,000 | 5,000 | 3,000 |
Moderate Hazard | 10,000 | 12,000 | 10,000 | |||||||
H-3. | Garages | 40,000 | 35,000 | 30,000 | 15,000 | 20,000 | 15,000 | 10,000 | NP | NP |
I. | Hazardous Use | Maximum areas established in Chapter 13-112 | ||||||||
J. | Miscellaneous Buildings and Structures | Maximum areas established in Chapter 13-96 | ||||||||
NOTES: | ||||||||||
NL – Not Limited. In buildings of unlimited area, no portion of such buildings shall be more than 300 feet from an exterior wall facing an open, accessible space not less than 30 feet wide consisting of a public way, railroad right-of-way, waterway, park or a court, accessible from a public way; except that such maximum distance from an exterior wall may not be more than 500 feet in buildings of low hazard industrial or low hazard storage units. | ||||||||||
NP – Not Permitted. | ||||||||||
(a) These areas permitted only when the first floor construction and all construction below the first floor level is of Type I-A construction. | ||||||||||
(b) Theaters. | ||||||||||
(c) Assembly units other than theaters. | ||||||||||
See Section 13-48-090 for allowable increase in areas for frontage and automatic sprinkler equipment. | ||||||||||
(d) All buildings of Type II and III-A and III-B construction having unlimited areas shall be provided with an automatic sprinkler system. | ||||||||||
Number of Stories Factor
2 1.00
3 0.90
4 0.85
5 0.80
6 0.75
7 0.70
8 or more 0.65
(See Table 13-48-080.)
(Prior code § 51-2.3)
Occupancy Classification | Construction Type | |||||||||
I-A | I-B | I-C | II | III-A | III-B | III-C | IV-A | IV-B |
Occupancy Classification | Construction Type | |||||||||
I-A | I-B | I-C | II | III-A | III-B | III-C | IV-A | IV-B | ||
A. | Residential | NL | NL | 20,000 | NP | 8,000 | 8,000 | 6,000 | 4,000 | 2,000 |
B. | Institutional | 30,000 | 16,000 | 12,000 | NP | NP | NP | NP | NP | NP |
C-1. | Assembly | NL | NL | 16,000 | NP | 6,000 | 6,000 | NP | NP | NP |
C-2. | Small Assembly | NL | NL | 16,000 | NP | 6,000 | 6,000 | NP | NP | NP |
C-3. | Schools | NL | NL | 16,000 | NP | 6,000 | 6,000 | NP | NP | NP |
D. | Open Air Assembly | Maximum areas established in Chapter 55 | ||||||||
E. | Business | NL | NL | 20,000 | NP | 10,000 | 10,000 | 8,000 | NP | NP |
F. | Mercantile | 30,000 | 20,000 | 16,000 | NP | 8,000 | 8,000 | 6,000 | NP | NP |
G-1. | Industrial Low-Hazard | NL | 30,000 | 20,000 | 10,000 | 10,000 | 10,000 | 8,000 | NP | NP |
G-2. | Industrial Moderate- Hazard | 30,000 | 20,000 | 16,000 | NP | 8,000 | 8,000 | 6,000 | NP | NP |
H-1. | Storage Low-Hazard | NL | 30,000 | 20,000 | 10,000 | 10,000 | 10,000 | 8,000 | NP | NP |
H-2. | Storage Moderate- Hazard | 30,000 | 20,000 | 16,000 | NP | 8,000 | 8,000 | 6,000 | NP | NP |
H-3. | Garages | 25,000 | 15,000 | 10,000 | NP | 6,000 | 6,000 | NP | NP | NP |
I. | Hazardous-Use | Maximum areas established in Chapter 60 | ||||||||
J. | Miscellaneous Buildings & Structures | Maximum areas established in Chapter 61 | ||||||||
NOTES: | ||||||||||
NL – Not Limited. In buildings of unlimited area, no portion of such buildings shall be more than 300 feet from an exterior wall facing an open, accessible space not less than 30 feet wide consisting of a public way, railroad right-of-way, waterway, park or a court, accessible from a public way; except that such maximum distance from an exterior wall may not be more than 500 feet in buildings of low hazard industrial or low hazard storage units. | ||||||||||
NP – Not Permitted. | ||||||||||
See Section 13-48-090 for allowable increase in areas for frontage and automatic sprinkler equipment. | ||||||||||