Type 2 stages shall conform to the following construction requirements.
(a) Enclosure. The stage block, including the stage, and dressing rooms, storage rooms, property rooms, workshops and other rooms appurtenant to the operation thereof, shall be enclosed by walls, floors and roof of noncombustible materials providing fire resistance of not less than one hour.
(b) Stage Floor. Except where trap doors are permitted for the working of scenery, traps and appliances, the stage floor shall be of construction not less fire-resistive than Type I-C. The location of trap doors shall conform to the requirements for Type 1 stages.
(c) Auxiliary Rooms. Dressing rooms, storage rooms, property rooms, workshops and other rooms appurtenant to the stage shall be of construction not less fire-resistive than Type I-C.
(d) Equipment. Rigging lofts, lighting troughs and electrical equipment shall conform to the requirements for Type 1 stages.
(e) All shelving, lockers and similar fixtures in dressing rooms, property rooms or storage rooms shall be constructed by noncombustible materials.
(Prior code § 54-6.3)