Skip to code content (skip section selection)
Compare to:

You are viewing an archived code

Loading...
15-8-325  Reserved.
Editor's note – Coun. J. 3-29-17, p. 45477, § 5, repealed § 15-8-325, pertaining to fire-protective treatments and coatings.
15-8-326  Pergolas, trellises, arbors, and privacy screens.
   (a)   Vertical elements of pergolas, trellises, arbors, privacy screens, and similar structures greater than 42 inches in height above the adjacent walking surface of a balcony, porch, deck, rooftop deck, or roof shall be treated as fences and comply with Section 13-96-120.
      (1)   Any element classified as a combustible solid fence shall be located not less than six feet from an interior lot line and not less than six feet from another building on the same lot.
      (2)   Any element classified as a combustible screen fence shall be located not less than three feet from an interior lot line and not less than six feet from another building on the same lot.
      (3)   Any element classified as a noncombustible fence may be used without regard to separation distance.
   (b)   Horizontal elements of pergolas, arbors, and similar structures shall be of noncombustible construction unless located not less than three feet from an interior lot line and not less than six feet from another building on the same lot.
   (c)   Combustible pergolas, trellises, arbors, privacy screens, and similar structures installed on a balcony, porch, deck, rooftop deck, roof, or similar surface shall not exceed 12 feet in height above the highest adjacent walking surface.
   (d)   Guards required by Section 13-124-310 and no greater than 42 inches in height may be constructed of combustible material if located not less than three feet from an interior lot line and not less than six feet from another building on the same lot.
   (e)   Any structure above a rooftop deck which provides protection from weather from above equivalent to a roof and projects more than 24 inches horizontally from a wall or other support shall be treated as a part of the building to which it is attached for purposes of determining the construction type, building height, and number of stories.
(Added Coun. J. 3-29-17, p. 45477, § 5)
15-8-330  Roof coverings.
   All roof coverings shall comply with the provisions of Sections 15-8-340 to 15-8-360, inclusive.
(Prior code §  62-8)
15-8-340  Classification.
   All roof coverings shall be classified in accordance with their fire-resistant properties as follows:
   Class A. Roof coverings effective against severe fire exposure;
   Class B. Roof coverings effective against moderate fire exposure;
   Class C. Roof coverings effective against light fire exposure.
(Prior code §  62-8)
15-8-350  Materials.
   The classification of any specific material shall be determined as provided in Section 15-12-260.
(Prior code §  62-8.2)
15-8-360  Use.
   Every roof placed on a building or structure shall be covered with Class A or Class B roof coverings except that Class C roof coverings shall be accepted on:
   (1)   Buildings of one-family or two-family residential use;
   (2)   Buildings of wood frame construction;
   (3)   Buildings located outside of the fire limits which on the basis of height and area could be of wood frame construction under this Code.
(Prior code § 62-8.3; Amend Coun. J. 11-9-16, p. 36266, § 30)
Loading...