Buildings of Type II construction, when permitted, shall be located not less than three feet from an interior lot line and not less than six feet from another building on the same lot unless the wall facing such lot line or adjoining building is constructed of materials providing fire resistance of not less than two hours and with all openings protected as required in Section 15-8-110.
(Prior code § 50-5)
Within the fire limits no building or structure shall be extended on any side by wood frame construction or unprotected noncombustible construction. When extensions are made to a building or structure of wood frame construction or unprotected noncombustible construction, the aggregate area of the building or structure including the extension shall not exceed the allowable area for wood frame construction in either Table 13-48-070 codified in Section 13-48-070 or Table 13-48-080 codified in Section 13-48-080.