The remaining sections in this chapter represent amendments to the requirements contained in the IBC. In the event requirements of this code conflict with applicable State and/or Federal requirements, the more stringent shall apply except that all references to flood hazard construction shall be coordinated in concurrence with Ankeny NFIP adoption dated 1-February-2019.ICC A117.1 references throughout this code shall denote ICC A117.1-09.
Section 101.4, Referenced Codes, of the IBC, is hereby amended by the following subsections:
Section 101.4.1 Gas. Strike International and insert in lieu thereof Ankeny.
Section 101.4.2 Mechanical. Strike International and insert in lieu thereof Ankeny.
Section 101.4.3 Plumbing. Strike International and insert in lieu thereof Ankeny.
Section 101.4.4 Property Maintenance. Strike International Property Maintenance and insert in lieu thereof Ankeny Property Maintenance and Housing.
Section 101.4.5 Fire Prevention. Strike International and insert in lieu thereof Ankeny.
Section 101.4.6 Energy. Strike International and insert in lieu thereof Ankeny.
Section 101.4.7 Existing Buildings. Strike International and insert in lieu thereof Ankeny.
Section 101.4.6, Energy, of the IBC, is hereby amended by deleting said section and inserting in lieu thereof the following section:
Section 101.4.6 Energy. The provisions of the International Energy Conservation Code as currently adopted and amended by the Iowa State Building Code Bureau shall apply to all matters governing the design and construction of buildings for energy efficiency. Administration shall be as prescribed in "this code' and these regulations shall be known as the Ankeny Energy Code. Construction or work for which a permit is required shall be subject to 3rd party inspections. The Code Official is authorized to accept reports of approved inspection agencies, provided such agencies satisfy the requirements as to qualifications and reliability. Any portion that does not comply shall be corrected and such portion shall not be covered or concealed until authorized by the Code Official.
Section C401.2 Application. Section C401.2, Application, of the IECC, is hereby amended by adding the following exception:
Seasonal Structures. The following Seasonal type structures are exempt from meeting the provisions of the energy code.
1. Food service buildings that serve patrons at amusement parks, water parks and outdoor sporting facilities that contain operable exterior walls openings on one or more walls which equal at least 40% or more of the overall exterior wall space.
2. Restroom Facilities that serve amusement parks, water parks and outdoor sporting facilities.
These facilities are allowed to have heating and/or cooling equipment for the temporary comfort of patrons and employees during operating hours.