175.21 SECTION 113 AMENDED - MEANS OF APPEAL.
Section 113, Means of Appeal, of the IBC, is hereby amended by deleting said section and inserting in lieu thereof the following:
 Section 113 Board of Examiners and Appeals Pursuant to the Ankeny Municipal Code, there is hereby created the Ankeny Board of Examiners and Appeals. Appeals shall be in accordance thereof.
175.22 SECTION 202 AMENDED - DEFINITIONS.
Section 202, Definitions, of the IBC, is hereby amended by deleting the definition of swimming pool and inserting in lieu thereof the following:
Section 202 Swimming Pool Any structure intended for swimming, recreational bathing, wading, or aesthetic purposes that is capable of containing water over 24 inches deep. This includes in-ground, above-ground, and on-ground pools, hot tubs, spas, fixed-in-place wading pools, and landscape ponds, but excludes manmade lakes or ponds created through the collection of storm water or drainage runoff.
175.23 SECTION 305.2.3 AMENDED - FIVE OR FEWER CHILDREN IN A DWELLING UNIT.
Section 305.2.3, Five Or Fewer Children In A Dwelling Unit, of the IBC, is hereby amended by deleting said section and inserting in lieu thereof the following section and exception:
Section 305.2.3 Eight Or Fewer Children In A Dwelling Unit. A facility such as the above within a dwelling unit and having eight or fewer children receiving such day care shall be classified as a Group R-3 occupancy or shall comply with the International Residential Code.
Exception: Day care facilities that provide custodial care for16 or fewer persons for less than 24-hours per day in a single-family dwelling, and where registered with the State of Iowa Department of Human Services as child development homes on or before January 1, 2017, are permitted to comply with the International Residential Code.
175.24 SECTION 310.4.1 AMENDED - CARE FACILITIES WITHIN A DWELLING UNIT.
Section 310.4.1, Care Facilities Within A Dwelling Units, of the IBC, is hereby amended by deleting said section and inserting in lieu thereof the following section:
Section 310.4.1 Care Facilities Within A Dwelling Unit. Care facilities within a dwelling unit shall be in accordance with section 305.2.3.
175.25 SECTION 406.3.2.1 AMENDED - DWELLING UNIT SEPARATION.
Section 406.3.2.1, Separation, of the IBC, is hereby amended by deleting said section and inserting in lieu thereof the following:
Section 406.3.2.1 Dwelling Unit Separation The private garage shall be separated from the dwelling unit and its attic area by means of minimum 5/8-inch type "X" fire code gypsum board or equivalent applied to the garage side. Where the separation is a floor-ceiling assembly, the structure supporting the separation shall also be protected by not less than 5/8-inch type "X" fire code gypsum board or equivalent throughout. Garages beneath habitable rooms shall be separated by not less than 5/8-inch type "X" fire code gypsum board or equivalent throughout. Door openings between a private garage and the dwelling unit shall be equipped with either solid wood doors or solid or honeycomb core steel doors not less than 1 3/8" thick, or doors in compliance with 716.2.2.1. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Doors shall be self-closing and self-latching.