Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
CHAPTER 18-11 RESERVED*
CHAPTER 18-13 RESERVED*
CHAPTER 18-14 BUILDING ENERGY USE BENCHMARKING
CHAPTER 18-27 RESERVED*
CHAPTER 18-28 MECHANICAL SYSTEMS*
CHAPTER 18-29 PLUMBING*
Article 1. Administration (18-29-101 et seq.)
Article 2. Definitions (18-29-201 et seq.)
Article 3. General Regulations (18-29-301 et seq.)
Article 4. Fixtures, Faucets and Fixture Fittings (18-29-401 et seq.)
Article 5. Water Heaters (18-29-501 et seq.)
Article 6. Water Supply and Distribution (18-29-601 et seq.)
Article 7. Sanitary Drainage (18-29-701 et seq.)
18-29-701 General.
18-29-701.1 Scope.
18-29-701.2 Sewer required.
18-29-701.3 Separate building sewer connection.
18-29-701.4 Sewage treatment.
18-29-701.5 Damage to drainage system or public sewer.
18-29-701.6 Tests.
18-29-701.7 Connections.
18-29-701.8 Notification of wrecking buildings and sealing or abandoning sewer facilities.
18-29-702 Materials.
18-29-702.1 Above-ground sanitary drainage and vent pipe.
18-29-702.1.1 Mixed-occupancy buildings.
18-29-702.2 Underground building sanitary drainage and vent pipe.
18-29-702.3 Building sewer pipe.
18-29-702.4 Fittings.
18-29-702.5 Temperature rating.
18-29-702.5.1 Reserved.
18-29-702.5.1.1 Reserved.
18-29-702.5.1.2 Reserved.
18-29-702.5.1.3 Reserved.
18-29-702.6 Chemical waste system.
18-29-702.6.1 Reserved.
18-29-702.6.2 Reserved.
18-29-702.7 Reserved.
18-29-702.8 Safe pans.
18-29-702.8.1 Material.
18-29-702.8.2 Construction.
18-29-703 Building Sewer.
18-29-703.1 Building sewers, building drains or drainage systems installed near the water pipes and water supply system.
18-29-703.2 Drainage pipe in filled ground.
18-29-703.3 Sanitary and storm sewers.
18-29-703.3.1 Combined sewers.
18-29-703.4 Existing building sewers and drains.
18-29-703.4.1 Inspection of existing underground building sewers for drain and reuse.
18-29-704 Drainage Piping and Installation.
18-29-704.1 Slope of horizontal drainage piping.
18-29-704.2 Change in size.
18-29-704.3 Connections to offsets and bases of stacks.
18-29-704.4 Future fixtures.
18-29-704.5 Reserved.
18-29-704.5.1 Reserved.
18-29-704.5.2 Reserved.
18-29-705 Joints.
18-29-705.1 General.
18-29-705.2 Deliberately omitted.
18-29-705.3 Deliberately omitted.
18-29-705.4 Reserved.
18-29-705.4.1 Reserved.
18-29-705.4.2 Reserved.
18-29-705.4.3 Reserved.
18-29-705.4.4 Reserved.
18-29-705.5 Cast iron.
18-29-705.5.1 Caulked joints.
18-29-705.5.2 Compression gasket joints.
18-29-705.5.3 Mechanical joint coupling.
18-29-705.6 Concrete joints.
18-29-705.7 Copper pipe.
18-29-705.7.1 Brazed joints.
18-29-705.7.2 Mechanical joints.
18-29-705.7.3 Soldered joints.
18-29-705.7.4 Threaded joints.
18-29-705.7.5 Welded joints.
18-29-705.8 Copper tubing.
18-29-705.8.1 Brazed joints.
18-29-705.8.2 Mechanical joints.
18-29-705.8.3 Soldered joints.
18-29-705.9 Borosilicate glass joints.
18-29-705.9.1 Caulked joints.
18-29-705.10 Steel.
18-29-705.10.1 Threaded joints.
18-29-705.10.2 Mechanical joints.
18-29-705.11 Deliberately omitted.
18-29-705.12 PVC plastic.
18-29-705.12.1 Mechanical joints.
18-29-705.12.2 Solvent cementing.
18-29-705.12.3 Threaded joints.
18-29-705.13 Vitrified clay.
18-29-705.14 Polyethylene plastic.
18-29-705.14.1 Heat-fusion joints.
18-29-705.14.2 Mechanical joints.
18-29-705.15 Polyolefin plastic.
18-29-705.15.1 Heat-fusion joints.
18-29-705.15.2 Mechanical and compression sleeve joints.
18-29-705.16 Polyvinylidene fluoride plastic.
18-29-705.16.1 Heat-fusion joints.
18-29-705.16.2 Mechanical and compression sleeve joints.
18-29-705.17 Reserved.
18-29-705.18 Joints between different materials.
18-29-705.18.1 Copper pipe or tubing to cast-iron hub pipe.
18-29-705.18.2 Copper or copper-alloy pipe or tubing to galvanized steel pipe.
18-29-705.18.3 Cast-iron pipe to galvanized steel or brass pipe.
18-29-705.18.4 Plastic pipe or tubing to other piping material.
18-29-705.18.5 Deliberately omitted.
18-29-705.18.6 Borosilicate glass to other materials.
18-29-705.18.7 Stainless steel drainage systems to other materials.
18-29-705.19 Drainage slip joints.
18-29-705.20 Caulking ferrules.
18-29-705.21 Reserved.
18-29-705.22 Stainless steel drainage systems.
18-29-706 Connections Between Drainage Piping And Fixtures.
18-29-706.1 Connections and changes in direction.
18-29-706.2 Obstructions.
18-29-706.3 Installation of fittings.
18-29-707 Prohibited Joints and Connections.
18-29-707.1 Prohibited joints.
18-29-708 Cleanouts.
18-29-708.1 Scope.
18-29-708.2 Cleanout plugs.
18-29-708.3 Where required.
18-29-708.3.1 Horizontal drains within buildings.
18-29-708.3.2 Building sewers.
18-29-708.3.3 Changes of direction.
18-29-708.3.4 Base of stack.
18-29-708.3.5 Building drain and building sewer junction.
18-29-708.3.6 Manholes.
18-29-708.4 Concealed piping.
18-29-708.5 Opening direction.
18-29-708.6 Prohibited installation.
18-29-708.7 Minimum size.
18-29-708.8 Pipes 8 inches and larger.
18-29-708.9 Clearances.
18-29-708.10 Access.
18-29-709 Fixture Units.
18-29-709.1 Values for fixtures.
18-29-709.2 Fixtures not listed in Table 18-29-709.1.
18-29-709.3 Conversion of gpm flow to dfu values.
18-29-709.4 Deliberately omitted.
18-29-709.5 Values for indirect waste receptor.
18-29-709.5.1 Clear-water waste receptors.
18-29-710 Drainage System Sizing.
18-29-710.1 Maximum fixture unit load.
18-29-710.1.1 Sizing building drains and building sewers for combined sanitary and storm drainage.
18-29-710.1.2 Minimum size.
18-29-710.1.3 Horizontal stack offsets.
18-29-710.1.4 Vertical stack offsets.
18-29-710.2 Future fixtures.
18-29-710.3 Underground drainage piping.
18-29-711 Offsets in Drainage Piping in Buildings of Five Stories or More.
18-29-711.1 Horizontal branch connections above or below vertical stack offsets.
18-29-711.1.1 Omission of vents for vertical stack offsets.
18-29-711.2 Horizontal branch connections to horizontal stack offsets.
18-29-711.3 Horizontal stack offsets.
18-29-711.3.1 Omission of vents for horizontal stack offsets.
18-29-711.3.2 Suds pressure zones.
18-29-711.3.2.1 Height.
18-29-711.3.2.2 Upstream.
18-29-711.3.2.3 Downstream.
18-29-711.4 Offsets below lowest branch.
18-29-712 Sumps and Ejectors.
18-29-712.1 Building drains below sewer.
18-29-712.2 Check and gate valve required.
18-29-712.3 Sump design.
18-29-712.3.1 Sump pump.
18-29-712.3.2 Sump pit.
18-29-712.3.3 Discharge piping.
18-29-712.3.4 Maximum effluent level.
18-29-712.3.5 Ejector connection to the drainage system.
18-29-712.4 Sewage pumps and sewage ejectors.
18-29-712.4.1 Capacity.
18-29-712.4.2 Duplex equipment required.
18-29-713 Health Care Plumbing.
18-29-713.1 Scope.
18-29-713.2 Bedpan washers and clinical sinks.
18-29-713.3 Indirect waste.
18-29-713.4 Vacuum system station.
18-29-713.5 Bottle system.
18-29-713.6 Central disposal system equipment.
18-29-713.7 Central vacuum or disposal systems.
18-29-713.7.1 Piping.
18-29-713.7.2 Velocity.
18-29-713.8 Vent connections prohibited.
18-29-713.9 Local vents and stacks for bedpan washers.
18-29-713.9.1 Multiple installations.
18-29-713.9.2 Trap required.
18-29-713.9.3 Trap seal maintenance.
18-29-713.10 Sterilizer vents and stacks.
18-29-713.10.1 Drainage.
18-29-713.11 Sterilizer vent stack sizes.
18-29-713.11.1 Bedpan steamers.
18-29-713.11.2 Boiling-type sterilizers.
18-29-713.11.3 Pressure sterilizers.
18-29-713.11.4 Pressure instrument washer sterilizer sizes.
18-29-714 Deliberately omitted.
18-29-715 Backwater Valves.
18-29-715.1 Sewage backflow.
18-29-715.2 Fixture branches.
18-29-715.3 Material.
18-29-715.4 Seal.
18-29-715.5 Diameter.
18-29-715.6 Location.
18-29-716 Flood Control.
18-29-716.1 Flood control devices.
18-29-716.2 Flood control systems.
Article 8. Indirect/Special Waste (18-29-801 et seq.)
Article 9. Vents (18-29-901 et seq.)
Article 10. Traps, Separators and Interceptors (18-29-1001 et seq.)
Article 11. Storm Drainage (18-29-1101 et seq.)
Article 12. Swimming Pools and Other Swimming Facilities* (18-29-1201 et seq.)
Article 13. Referenced Standards
Appendix A Procedures for Calculating the Minimum Sizing of the Water Supply System
CHAPTER 18-30 RESERVED*
CHAPTER 18-31 RESERVED*
CHAPTER 18-32 RESERVED*
CHAPTER 18-36 REFERENCE STANDARDS*
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
18-29-708.3.6 Manholes.
   Manholes serving a building drain shall have secured gas-tight covers and shall be located in accordance with Section 18-29-708.8.
18-29-708.4 Concealed piping.
   Cleanouts on concealed piping, piping under a floor slab or piping in a crawl space of less than 36 inches (915 mm) in height, or piping in a plenum shall be extended through and shall terminate flush with the finished wall, floor or ground surface or shall be extended to the outside of the building. Cleanout plugs shall not be covered with cement, plaster or any other permanent finish material. Where it is necessary to conceal a cleanout or to terminate a cleanout in an area subject to vehicular traffic, the covering plate, access door or cleanout shall be of an approved type designed and installed for this purpose.
18-29-708.5 Opening direction.
   Every cleanout shall be installed to open to allow cleaning in the direction of the flow of the drainage pipe or at right angles thereto.
18-29-708.6 Prohibited installation.
   Cleanout openings shall not be utilized for the installation of new fixtures or floor drains, except where approved and where another cleanout of equal access and capacity is provided.
18-29-708.7 Minimum size.
   Cleanouts shall be the same nominal size as the pipe they serve up to 4 inches (100 mm). For pipes larger than 4 inches (100 mm) nominal size, the minimum size of the cleanout shall be 4 inches (100 mm).
   Exception: "P" trap connections with slip joints or ground joint connections, or stack cleanouts that are no more than one pipe diameter smaller than the drain served, shall be approved.
18-29-708.8 Pipes 8 inches and larger.
   For building sewers 8 inches (200 mm) and larger nominal size, manholes shall be provided and located at each change in direction greater than 45 degrees, and at the locations and intervals referenced in the current edition of the permit requirement and fees book.
18-29-708.9 Clearances.
   Cleanouts on 6-inch (150 mm) and smaller pipes shall be provided with a clearance of not less than 18 inches (457 mm) for rodding. Cleanouts on 8-inch (200 mm) and larger pipes shall be provided with a clearance of not less than 36 inches (914 mm) for rodding.
18-29-708.10 Access.
   Access shall be provided to all cleanouts.