Joints between PVC plastic pipe or fittings shall comply with Sections 18-29-705.12.1 through 18-29-705.12.3.
Mechanical joints on drainage pipe shall be made with an elastomeric seal conforming to ASTM C1173, ASTM D3212 or CSA CAN/CSA B602. Mechanical joints shall not be installed in above-ground systems, unless otherwise approved. Joints shall be installed in accordance with the manufacturer's instructions.
Joint surfaces shall be clean and free from moisture. A purple primer that conforms to ASTM F656 shall be applied. Solvent cement not purple in color and conforming to ASTM D2564, CSA CAN/CSA B137.3, CSA CAN/CSA B181.2 or CSA CAN/CSA B182.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet and shall be in accordance with ASTM D2855. Solvent-cement joints shall be permitted above or below ground.
Joints between polyethylene plastic pipe and fittings shall be underground and shall comply with Section 18-29-705.14.1 or 18-29-705.14.2.
(Added Coun. J. 10-14-21, p. 37722, Art. VII, § 5)
Joint surfaces shall be clean and free from moisture. Joint surfaces shall be cut, heated to melting temperature and joined using tools specifically designed for the operation. Joints shall be undisturbed until cool. Joints shall be made in accordance with ASTM D2657 and the manufacturer's instructions.
(Added Coun. J. 10-14-21, p. 37722, Art. VII, § 5)