18-29-702.4 Fittings.
   Pipe fittings shall be suitable for installation with the piping material and shall comply with the applicable standards listed in Table 18-29-702.4.
Table 18-29-702.4
Pipe Fittings
Material
Standard
Material
Standard
Cast iron
ASME B16.4; ASME B16.12; ASTM A74; ASTM A888; CISPI 301
Copper or copper-alloy
ASME B16.15; ASME B16.18; ASME B16.22; ASME B16.23; ASME B16.26; ASME B16.29
Glass
ASTM C1053
Gray iron and ductile iron
AWWA C110
Polyethylene (PE) a
ASTM D2683
Polyolefin a
ASTM F1412; CSA B181.3
Polyvinyl chloride (PVC) plastic in IPS diameters a, b
ASME A112.4.4; ASTM D2665; ASTM F1866
Polyvinyl chloride (PVC) plastic in sewer and drain diameters a, b
ASTM D3034
Polyvinyl chloride (PVC) plastic with a 3.25 inch O.D. a, b
ASTM D2949
Polyvinylidene fluoride (PVDF) plastic a
ASTM F1673; CSA B181.3
Stainless steel drainage systems, Types 304 and 316L
ASME A112.3.1
Steel
ASME B16.9; ASME B16.11; ASME B16.28
Vitrified clay pipe, extra strength
ASTM C700
 
For SI: 1 inch = 25.4 mm.
a.   Limited in accordance with notes a and c to Table 18-29-702.1 or for use with chemical waste systems in accordance with Section 18-29-702.6.
b.   Where used to comply with Section 18-29-602.3.1(c), PVC pipe fittings shall also comply with Section 653.111 of Title 35 of the Illinois Administrative Code.
(Amend Coun. J. 7-29-15, p. 3537, § 4; Amend Coun. J. 10-14-21, p. 37722, Art. VII, § 2; Amend Coun. J. 12-14-22, p. 58278, Art. VI, § 14)
18-29-702.5 Temperature rating.
   Where the wastewater temperature will be greater than 140°F (60°C), the sanitary drainage piping material shall be rated for the highest temperature of the wastewater.
(Amend Coun. J. 10-14-21, p. 37722, Art. VII, § 2)
18-29-702.5.1 Reserved.
Editor's note – Coun. J. 10-14-21, p. 37722, Art. VII, § 2, repealed § 18-29-702.5.1, which pertained to glass pipe.
18-29-702.5.1.1 Reserved.
Editor's note – Coun. J. 10-14-21, p. 37722, Art. VII, § 2, repealed § 18-29-702.5.1.1, which pertained to padding.
18-29-702.5.1.2 Reserved.
Editor's note – Coun. J. 10-14-21, p. 37722, Art. VII, § 2, repealed § 18-29-702.5.1.2, which pertained to thickness.
18-29-702.5.1.3 Reserved.
Editor's note – Coun. J. 10-14-21, p. 37722, Art. VII, § 2, repealed § 18-29-702.5.1.3, which pertained to buried pipe.
18-29-702.6 Chemical waste system.
   A chemical waste system shall be completely separated from the sanitary drainage system. The chemical waste shall be treated in accordance with Section 18-29-803.3 before discharging into the sanitary drainage system. Separate drainage systems for chemical wastes and vent pipes shall comply with the applicable standards listed in Table 18-29-702.1 or 18-29-702.6 and shall be made of materials that are resistant to corrosion and degradation for the concentrations of chemicals involved.
Table 18-29-702.6
Chemical Waste System Pipe
 
Material
Standard
Chlorinated polyvinyl chloride (CPVC) plastic pipe
ASTM F2618
Glass pipe
ASTM C1053
Polyolefin pipe
ASTM F1412; CSA B181.3
Polyvinylidene fluoride (PVDF) plastic pipe
ASTM F1673; CSA B181.3
 
(Amend Coun. J. 10-14-21, p. 37722, Art. VII, § 2)
18-29-702.6.1 Reserved.
Editor's note – Coun. J. 10-14-21, p. 37722, Art. VII, § 2, repealed § 18-29-702.6.1, which pertained to material.
18-29-702.6.2 Reserved.
Editor's note – Coun. J. 10-14-21, p. 37722, Art. VII, § 2, repealed § 18-29-702.6.2, which pertained to construction.
18-29-702.7 Reserved.
(Added Coun. J. 10-14-21, p. 37722, Art. VII, § 2)
18-29-702.8 Safe pans.
   Safe pans shall conform to the material and construction requirements in Sections 18-29-702.8.1 through 18-29-702.8.2.