Loading...
Mechanical joints on drainage pipe shall be made with an elastomeric seal conforming to ASTM C1173, ASTM D3212 or CSA CAN/CSA B602. Mechanical joints shall not be installed in above-ground systems, unless otherwise approved. Joints shall be installed in accordance with the manufacturer's instructions.
Joint surfaces shall be clean and free from moisture. A purple primer that conforms to ASTM F656 shall be applied. Solvent cement not purple in color and conforming to ASTM D2564, CSA CAN/CSA B137.3, CSA CAN/CSA B181.2 or CSA CAN/CSA B182.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet and shall be in accordance with ASTM D2855. Solvent-cement joints shall be permitted above or below ground.
Joints between polyethylene plastic pipe and fittings shall be underground and shall comply with Section 18-29-705.14.1 or 18-29-705.14.2.
(Added Coun. J. 10-14-21, p. 37722, Art. VII, § 5)