TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
CHAPTER 18-11 RESERVED*
CHAPTER 18-13 RESERVED*
CHAPTER 18-14 BUILDING ENERGY USE BENCHMARKING
CHAPTER 18-27 RESERVED*
CHAPTER 18-28 MECHANICAL SYSTEMS*
CHAPTER 18-29 PLUMBING*
Article 1. Administration (18-29-101 et seq.)
Article 2. Definitions (18-29-201 et seq.)
Article 3. General Regulations (18-29-301 et seq.)
18-29-301 General.
18-29-301.1 Scope.
18-29-301.1.1 Reserved.
18-29-301.1.2 Reserved.
18-29-301.2 System installation.
18-29-301.3 Connections to drainage system.
18-29-301.4 Connections to water supply.
18-29-301.5 Pipe, tube and fitting sizes.
18-29-301.6 Prohibited locations.
18-29-301.7 Conflicts.
18-29-302 Exclusion of Materials Detrimental to the Sewer System.
18-29-302.1 Detrimental or dangerous materials.
18-29-302.2 Industrial wastes.
18-29-303 Materials.
18-29-303.1 Identification.
18-29-303.2 Installation of materials.
18-29-303.3 Plastic pipe, fittings and components.
18-29-303.4 Third-party certification.
18-29-303.4.1 Reserved.
18-29-303.4.2 Reserved.
18-29-303.4.2.1 Reserved.
18-29-303.4.2.2 Reserved.
18-29-303.4.2.3 Reserved.
18-29-303.5 Cast-iron soil pipe, fittings and components.
18-29-304 Rodent-Proofing.
18-29-304.1 General.
18-29-304.2 Strainer plates.
18-29-304.3 Meter boxes.
18-29-304.4 Openings for pipes.
18-29-305 Protection of Pipes and Plumbing System Components.
18-29-305.1 Protection against contact.
18-29-305.2 Reserved.
18-29-305.3 Stress and strain.
18-29-305.4 Reserved.
18-29-305.5 Pipes through or under footings or foundation walls.
18-29-305.6 Freezing.
18-29-305.6.1 Sewer depth.
18-29-305.6.2 Water main depth.
18-29-305.7 Waterproofing of openings.
18-29-305.8 Protection against physical damage.
18-29-305.9 Protection of components of plumbing system.
18-29-306 Trenching, Excavation and Backfill.
18-29-306.1 Support of piping.
18-29-306.2 Trenching and bedding.
18-29-306.2.1 Overexcavation.
18-29-306.2.2 Rock removal.
18-29-306.2.3 Soft loadbearing materials.
18-29-306.3 Backfilling.
18-29-306.4 Tunneling.
18-29-306.5 Reserved.
18-29-307 Structural Safety.
18-29-307.1 General.
18-29-307.2 Cutting, notching or boring of holes.
18-29-307.3 Penetrations of floor/ceiling assemblies and fire-resistance-rated assemblies.
18-29-307.4 Protection of footings.
18-29-307.5 Alterations to trusses.
18-29-307.6 Piping material exposed within plenums.
18-29-308 Piping Support.
18-29-308.1 General.
18-29-308.2 Piping seismic supports.
18-29-308.3 Materials.
18-29-308.4 Structural attachment.
18-29-308.5 Interval of support.
18-29-308.6 Sway bracing.
18-29-308.7 Anchorage.
18-29-308.7.1 Location.
18-29-308.8 Expansion joint fittings.
18-29-308.8.1 Vertical expansion.
18-29-308.9 Stacks.
18-29-308.10 Parallel water distribution systems.
18-29-308.11 Thermal expansion tanks.
18-29-309 Floodproofing.
18-29-309.1 General.
18-29-309.1.1 Base flood elevation.
18-29-309.2 Deliberately omitted.
18-29-310 Washroom and Toilet Room Requirements.
18-29-310.1 Light and ventilation.
18-29-310.2 Location of fixtures and compartments.
18-29-310.3 Interior finish.
18-29-310.4 Reserved.
18-29-311 Toilet Facilities for Workers.
18-29-311.1 General.
18-29-312 Tests and Inspections.
18-29-312.1 Required tests.
18-29-312.2 Drainage and vent water test.
18-29-312.3 Deliberately omitted.
18-29-312.4 Deliberately omitted.
18-29-312.5 Water supply system test.
18-29-312.6 Gravity sewer test.
18-29-312.7 Forced sewer test.
18-29-312.8 Storm drainage system test.
18-29-312.9 Cross connection control device inspections.
18-29-313 Equipment Efficiencies.
18-29-313.1 General.
18-29-314 Condensate Disposal.
18-29-314.1 Fuel-burning appliances.
18-29-314.2 Evaporators and cooling coils.
18-29-314.2.1 Condensate disposal.
18-29-314.2.2 Drain pipe materials and sizes.
18-29-314.2.3 Auxiliary and secondary drain systems.
18-29-314.2.3.1 Water-level monitoring devices.
18-29-314.2.3.2 Appliance, equipment and insulation in pans.
18-29-314.2.4 Traps.
18-29-314.2.4.1 Ductless mini-split system traps.
18-29-314.2.5 Drain line maintenance.
18-29-315 Penetrations.
18-29-315.1 Sealing of annular spaces.
Article 4. Fixtures, Faucets and Fixture Fittings (18-29-401 et seq.)
Article 5. Water Heaters (18-29-501 et seq.)
Article 6. Water Supply and Distribution (18-29-601 et seq.)
Article 7. Sanitary Drainage (18-29-701 et seq.)
Article 8. Indirect/Special Waste (18-29-801 et seq.)
Article 9. Vents (18-29-901 et seq.)
Article 10. Traps, Separators and Interceptors (18-29-1001 et seq.)
Article 11. Storm Drainage (18-29-1101 et seq.)
Article 12. Swimming Pools and Other Swimming Facilities* (18-29-1201 et seq.)
Article 13. Referenced Standards
Appendix A Procedures for Calculating the Minimum Sizing of the Water Supply System
CHAPTER 18-30 RESERVED*
CHAPTER 18-31 RESERVED*
CHAPTER 18-32 RESERVED*
CHAPTER 18-36 REFERENCE STANDARDS*
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
18-29-308 Piping Support.
18-29-308.1 General.
   All plumbing piping shall be supported in accordance with this section.
18-29-308.2 Piping seismic supports.
   Where earthquake loads are applicable in accordance with the Chicago Building Code, plumbing piping supports, anchorage and bracing shall be designed and installed for seismic forces in accordance with Chapter 14B-16.
(Amend Coun. J. 10-14-21, p. 37722, Art. III, § 16)
18-29-308.3 Materials.
   Hangers, anchors and supports shall support the piping and the contents of the piping. Hangers and strapping material shall be of approved material that will not promote galvanic action.
18-29-308.4 Structural attachment.
   Hangers and anchors shall be attached to the building construction in an approved manner.
18-29-308.5 Interval of support.
   Pipe shall be supported in accordance with Table 18-29-308.5.
Table 18-29-308.5
Hanger Spacing
 
Piping Material
Maximum Horizontal Spacing (feet)
Maximum Vertical Spacing (feet)
Cast-iron pipe
5 a
15
Copper or copper-alloy pipe
12
10
Copper or copper-alloy tubing,
1 1/4-inch diameter and smaller
6
10
Copper or copper-alloy tubing,
1 1/2-inch diameter and larger
10
10
Polyvinyl chloride (PVC) pipe
4
10 b
Stainless steel drainage systems
10
10 b
 
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
a.   The maximum horizontal spacing of cast-iron pipe hangers shall be increased to 10 feet where 10-foot lengths of pipe are installed.
b.   For sizes 2 inches and smaller, a guide shall be installed midway between required vertical supports. Such guides shall prevent pipe movement in a direction perpendicular to the axis of the pipe.
(Amend Coun. J. 3-27-02, p. 82090, § 3; Amend Coun. J. 10-14-21, p. 37722, Art. III, § 17)
18-29-308.6 Sway bracing.
   Rigid support sway bracing shall be provided at changes in direction greater than 45 degrees (0.79 rad) for pipe sizes 6 inches (150 mm) and larger.
18-29-308.7 Anchorage.
   Anchorage shall be provided to restrain drainage piping from axial movement.
Loading...