In the process of installing or repairing any part of a plumbing and drainage installation, the finished floors, walls, ceilings, tile work or any other part of the building or premises that must be changed or replaced shall be left in a safe structural condition and shall maintain required fire resistance in accordance with the requirements of the building code.
Penetrations of floor/ceiling assemblies and assemblies required to have a fire-resistance rating shall be protected in accordance with the Chicago Building Code.
(Amend Coun. J. 4-10-19, p. 100029, Art. XVI, § 7; Amend Coun. J. 10-14-21, p. 37722, Art. III, § 12)
Trenching installed parallel to footings shall not extend into the bearing plane of a footing or wall. The upper boundary of the bearing plane is a line that extends downward, at an angle of 45 degrees (0.79 rad) from horizontal, from the outside bottom edge of the footing or wall.
(Amend Coun. J. 10-14-21, p. 37722, Art. III, § 13)
Truss members and components shall not be cut, drilled, notched, spliced or otherwise altered in any way without written approval of a registered design professional. Alterations resulting in the addition of loads to any member (such as HVAC equipment and water heaters) shall not be made without verification by a registered design professional that the truss is capable of supporting such additional loading.
(Added Coun. J. 10-14-21, p. 37722, Art. III, § 14)