Toilet facilities shall be provided for construction workers in quantities and at locations specified in regulations of the Occupational Safety and Health Administration (OSHA). Such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to PSAI Z4.3. Where placed outdoors at ground level, toilet facilities of the nonsewer type shall be located at least 5 feet (1524 mm) from abutting property lines.
(Amend Coun. J. 10-14-21, p. 37722, Art. III, § 22)
Permit holders shall make applicable tests prescribed in Sections 18-29-312.2 through 18-29-312.9 to determine compliance with provisions of this chapter. A permit holder shall give reasonable advance notice to the building commissioner and the commissioner of water management when plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. All plumbing system piping shall be tested with either water, smoke or air.
(Amend Coun. J. 3-5-03, p. 104990, § 48; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1)
The water pressure test for plumbing shall be applied by closing the lower end of the vertical pipes and filling the pipes to the highest opening above the roof with water. The air pressure test for plumbing shall be applied with a force pump and mercury column equal to 10 inches (250 mm) of mercury. The use of spring gauges is prohibited. Special provision shall be made to include all joints and connections to the finished line or face of floors or side walls, so that all vents or revents, including lead work, may be tested with the main stacks. All pipes shall remain uncovered in every part until they have successfully passed the test.
Loading...