2507.1 General.
Lathing and plastering materials and accessories shall be marked by the manufacturer's designation to indicate compliance with the appropriate standards referenced in this section and stored in such a manner to protect them from the weather.
2507.2 Standards.
Lathing and plastering materials shall conform to the standards listed in Table 2507.2 and Chapter 35 and, where required for fire protection, shall also conform to the provisions of Chapter 7.
Material | Standard |
Material | Standard |
Accessories for gypsum veneer base | ASTM C 1047 |
Blended cement | ASTM C 595 |
Cold-formed steel studs and track, nonstructural | AISI S220 and ASTM C 645, Section 10 |
Cold-formed steel studs and track, structural | AISI S200 and ASTM C 955, Section 8 |
Exterior plaster bonding compounds | ASTM C 932 |
Gypsum casting and molding plaster | ASTM C 59 |
Gypsum Keene's cement | ASTM C 61 |
Gypsum plaster | ASTM C 28 |
Gypsum veneer plaster | ASTM C 587 |
Hydraulic cement | ASTM C 1157; C 1600 |
Interior bonding compounds, gypsum | ASTM C 631 |
Lime plasters | ASTM C 5; C 206 |
Masonry cement | ASTM C 91 |
Metal lath | ASTM C 847 |
Plaster aggregates Sand Perlite Vermiculite | ASTM C 35; C 897 ASTM C 35 ASTM C 35 |
Plastic cement | ASTM C 1328 |
Portland cement | ASTM C 150 |
Steel screws | ASTM C 1002; C 954 |
Welded wire lath | ASTM C 933 |
Woven wire plaster base | ASTM C 1032 |
2508.1 General.
Gypsum board, gypsum panel products and gypsum plaster construction shall be of the materials listed in Tables 2506.2 and 2507.2. These materials shall be assembled and installed in compliance with the appropriate standards listed in Tables 2508.1 and 2511.1.1, and Chapter 35.
Material | Standard |
Material | Standard |
Gypsum board and gypsum panel products | GA-216; ASTM C 840 |
Gypsum sheathing and gypsum panel products | ASTM C 1280 |
Gypsum board (Interior) | ASTM C 1396 |
Gypsum board (Exterior) | ASTM C 1396 |
Gypsum veneer base | ASTM C 844 |
Interior bathing and furring | ASTM C 841 |
Steel framing for gypsum board and gypsum panel products | ASTM C 754; C 1007 |
2508.2 Limitations.
Gypsum wallboard or gypsum plaster shall not be used in any exterior surface where such gypsum construction will be exposed directly to the weather. Gypsum wallboard shall not be used where there will be direct exposure to water or continuous high humidity conditions beyond the published recommendations of the manufacturer. Gypsum sheathing shall be installed on exterior surfaces in accordance with ASTM C 1280.