2510.7 Preparation of masonry and concrete.
Surfaces shall be clean, free from efflorescence, sufficiently damp and rough for proper bond. If the surface is insufficiently rough, approved bonding agents or a portland cement dash bond coat mixed in proportions of not more than two parts volume of sand to one part volume of portland cement or plastic cement shall be applied. The dash bond coat shall be left undisturbed and shall be moist cured not less than 24 hours.
2511.1 General.
Plastering gypsum plaster or cement plaster shall not be less than three coats where applied over metal lath or wire fabric lath and not less than two coats where applied over other bases permitted by this chapter.
Exception: Gypsum veneer plaster and cement plaster specifically designed and approved for one-coat applications.
2511.1.1 Installation.
Installation of lathing and plaster materials shall conform to Table 2511.1.1 and Section 2507.
Material | Standard |
Cement plaster | ASTM C 926 |
Gypsum plaster | ASTM C 842 |
Gypsum veneer plaster | ASTM C 843 |
Interior lathing and furring (gypsum plaster) | ASTM C 841 |
Lathing and furring (cement plaster) | ASTM C 1063 |
Steel framing | ASTM C 754; C 1007 |
Loading...