Section 304.14, Insect Screens, of the IPMC, is hereby amended by inserting the following dates and deleting a portion of the last sentence as follows:
Section 304.14 Insect screens (from date) April 1 (to date) October 31
Delete: and every screen door used for insect control shall have a self-closing device in good working condition.
Section 403.5, Clothes dryer duct, of the IPMC, is hereby amended by adding the following section:
Section 403.5.1 Clothes dryer duct Transition ducts, in rental dwelling units and buildings, used to connect the dryer to the exhaust duct system shall be a single length that is listed and labeled in accordance with UL 2158A. Transition ducts shall be a maximum of 8 feet (2438 mm) in length and shall not be concealed within construction.
Section 404.4.1, Room Area, of the IPMC, is hereby amended by deleting said section and inserting in lieu thereof the following:
Section 404.4.1 Room area Every living room shall contain at least 120 square feet and every bedroom shall contain at least 70 square feet. Where more than two persons occupy a bedroom the required floor area shall be increased at the rate of 50 square feet for each occupant in excess of two.