177.18 SECTION 605.2 AMENDED - RECEPTACLES.
Section 605.2, receptacles, of the IPMC, is hereby amended by deleting said section and inserting in lieu thereof the following:
Section 605.2 Receptacles Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounding-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain at least one receptacle and shall have ground fault circuit interrupter protection. All 125-volt, single phase, 15- and 20- ampere receptacles, in rental dwelling units, within six feet of the edge of a sink, bathtub or shower stall shall be provided with ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location.