In a P zone, the minimum side yard for any main building shall be twenty feet (20') unless reduced by the planning commission. On corner lots, the side yard which faces on a street, for both main and accessory buildings, shall be not less than twenty feet (20'). (Ord. 2016-19, 9-22-2016)
A. No building or structure in a P zone shall contain more than three (3) stories or forty five feet (45') maximum in height including screened mechanical equipment but excluding: 1) chimneys of six feet (6') or less; 2) architecturally compatible elevator shafts six feet (6') or less; and/or 3) gables four feet (4') or less. No structure shall contain less than one story.
B. Exceptions to this limit shall only be allowed by conditional use permit, for typical ornamental architectural features such as steeples and towers, etc., for buildings usually found in this zone. Such features shall not exceed sixty feet (60'). (Ord. 2016-19, 9-22-2016)
A. Prohibited Locations: No accessory building/structure may be constructed in a front setback area, nor shall it be placed within a required side setback area abutting a street. No accessory building/structure may be constructed within any public utility or other easement without the express written consent of all utility providers or parties holding interest in the easement.
B. Rear Yard Requirements: An accessory building/structure may be constructed in a rear yard provided the accessory building/structure:
1. Does not exceed twenty feet (20') in height above existing grade if located in any required setback;
2. Meets the graduated height requirement in subsection 13.14.070B2 of this title;
3. Is no closer to a rear property line than ten feet (10'); and
4. If located entirely within the buildable envelope, the height of the accessory building/structure shall not exceed the height of the main building/structure.
C. Side Yard Requirements: Accessory buildings/structures may be constructed between the primary structure and the side property line not abutting a street if the accessory buildings/structures:
1. Does not exceed twenty feet (20') in height above existing grade;
2. Meets the graduated height requirement in subsection 13.14.070B2 of this title; and
3. Does not encroach into the required side setback area (20 feet).
D. Setback Reduction: For properties located in the public use zone that abut properties in the HV zone the planning commission may grant a setback reduction for an accessory building to within three feet (3') of the property line for a rear yard and/or a side yard not abutting a public street, if the following can be met:
1. There are no residential structures within twenty feet (20') of the proposed accessory building; and
2. There are other mitigating conditions that the planning commission may deem necessary to justify a setback reduction. (Ord. 2016-19, 9-22-2016)