Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
CHAPTER 18-11 RESERVED*
CHAPTER 18-13 RESERVED*
CHAPTER 18-14 BUILDING ENERGY USE BENCHMARKING
CHAPTER 18-27 RESERVED*
CHAPTER 18-28 MECHANICAL SYSTEMS*
CHAPTER 18-29 PLUMBING*
Article 1. Administration (18-29-101 et seq.)
Article 2. Definitions (18-29-201 et seq.)
Article 3. General Regulations (18-29-301 et seq.)
Article 4. Fixtures, Faucets and Fixture Fittings (18-29-401 et seq.)
Article 5. Water Heaters (18-29-501 et seq.)
Article 6. Water Supply and Distribution (18-29-601 et seq.)
Article 7. Sanitary Drainage (18-29-701 et seq.)
Article 8. Indirect/Special Waste (18-29-801 et seq.)
Article 9. Vents (18-29-901 et seq.)
18-29-901 General.
18-29-901.1 Scope.
18-29-901.2 Trap seal protection.
18-29-901.2.1 Venting required.
18-29-901.3 Chemical waste vent system.
18-29-901.4 Use limitations.
18-29-901.5 Tests.
18-29-901.6 Protection from freezing.
18-29-902 Materials.
18-29-902.1 Vents.
18-29-902.2 Sheet copper.
18-29-902.3 Sheet lead.
18-29-903 Vent Stacks and Stack Vents.
18-29-903.1 Main vent required.
18-29-903.2 Vent stack required.
18-29-903.3 Vent termination.
18-29-903.4 Vent connection at base.
18-29-903.5 Vent headers.
18-29-904 Vent Terminals.
18-29-904.1 Vent terminals required.
18-29-904.1.1 Roof extension unprotected.
18-29-904.1.2 Occupiable rooftop.
18-29-904.1.3 Reserved.
18-29-904.1.4 Sidewall vent terminal.
18-29-904.2 Frost closure.
18-29-904.3 Flashings.
18-29-904.4 Prohibited use.
18-29-904.5 Location of vent terminal.
18-29-904.6 Extension outside a structure.
18-29-905 Vent Connections and Grades.
18-29-905.1 Connection.
18-29-905.2 Grade.
18-29-905.3 Vent connection to drainage system.
18-29-905.4 Vertical rise of vent.
18-29-905.5 Height above fixtures.
18-29-905.6 Side inlet.
18-29-905.7 Vent for future fixtures.
18-29-906 Fixture Vents.
18-29-906.1 Distance of trap from vent.
18-29-906.2 Venting of fixture drains.
18-29-906.3 Crown vent.
18-29-907 Individual Vent.
18-29-907.1 Individual vent permitted.
18-29-908 Common Vent.
18-29-908.1 Individual vent as common vent.
18-29-908.2 Connection at the same level.
18-29-908.3 Connection of different levels.
18-29-909 Deliberately omitted.
18-29-910 Deliberately omitted.
18-29-911 Deliberately omitted.
18-29-912 Combination Drain and Vent System.
18-29-912.1 Type of fixtures.
18-29-912.2 Waste piping and trap.
18-29-912.2.1 Branches.
18-29-912.2.2 Sinks, lavatories, and other fixtures.
18-29-912.2.3 Long mains.
18-29-912.2.4 Floor drains.
18-29-912.3 Size.
18-29-913 Island Fixture Venting.
18-29-913.1 Limitation.
18-29-913.2 Vent connection.
18-29-913.3 Vent installation below the fixture flood level rim.
18-29-914 Relief Vents - Stacks of More Than 10 Branch Intervals.
18-29-914.1 Where required.
18-29-914.2 Size and connection.
18-29-915 Vents for Stack Offsets.
18-29-915.1 Vent for horizontal offset of drainage stack.
18-29-915.2 Upper section.
18-29-915.3 Lower section.
18-29-916 Vent Pipe Sizing.
18-29-916.1 Size of stack vents and vent stacks.
18-29-916.2 Vents other than stack vents or vent stacks.
18-29-916.3 Developed length.
18-29-916.4 Multiple branch vents.
18-29-916.4.1 Reserved.
18-29-916.5 Sump vents.
18-29-916.5.1 Sewage pumps and sewage ejectors other than pneumatic.
18-29-916.5.2 Pneumatic sewage ejectors.
18-29-917 Vents Not Required.
18-29-917.1 Not required.
18-29-918 Deliberately omitted.
Article 10. Traps, Separators and Interceptors (18-29-1001 et seq.)
Article 11. Storm Drainage (18-29-1101 et seq.)
Article 12. Swimming Pools and Other Swimming Facilities* (18-29-1201 et seq.)
Article 13. Referenced Standards
Appendix A Procedures for Calculating the Minimum Sizing of the Water Supply System
CHAPTER 18-30 RESERVED*
CHAPTER 18-31 RESERVED*
CHAPTER 18-32 RESERVED*
CHAPTER 18-36 REFERENCE STANDARDS*
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
18-29-912.2.1 Branches.
   A branch more than 15 feet (4.57 m) in length shall be separately vented. The minimum area of any vent installed in a combination waste and vent system shall be one-half the diameter of the drain pipe served, but not less than the minimum indicated in Table 18-29-916.1.
18-29-912.2.2 Sinks, lavatories, and other fixtures.
   Sinks, lavatories and other fixtures that are roughed-in above the floor shall not be permitted on a combination waste and vent.
18-29-912.2.3 Long mains.
   Long mains shall be provided with additional relief vents located at intervals of every 100 feet (30.48 m).
18-29-912.2.4 Floor drains.
   Floor drains shall be vented at the end of the waste line or individually vented.
18-29-912.3 Size.
   The minimum size of a combination drain and vent pipe shall be in accordance with Table 18-29-912.3.
Table 18-29-912.3
Size of Combination Drain and Vent Pipe
(for Floor Drains Only)
Diameter Pipe (inches)
Maximum Number of Drainage Fixture Units
Connecting to a horizontal branch or stack
Connecting to a building drain or building subdrain
Diameter Pipe (inches)
Maximum Number of Drainage Fixture Units
Connecting to a horizontal branch or stack
Connecting to a building drain or building subdrain
2
3
4
2 1/2
6
26
3
12
31
4
20
50
5
160
250
6
360
575
 
For SI: 1 inch = 25.4 mm.
18-29-913 Island Fixture Venting.
18-29-913.1 Limitation.
   Island fixture venting shall not be permitted for fixtures other than sinks and lavatories. Residential kitchen sinks with a dishwasher waste connection, a food waste grinder, or both, in combination with the kitchen sink waste, shall be permitted to be vented in accordance with this section.
18-29-913.2 Vent connection.
   The island fixture vent shall connect to the fixture drain as required for an individual or common vent. The vent shall rise 6 inches (150 mm) vertically above the flood rim level of the fixture being vented before offsetting horizontally or vertically downward before connecting to the outside vent terminal.
18-29-913.3 Vent installation below the fixture flood level rim.
   The vent located below the flood level rim of the fixture being vented shall be installed as required for drainage piping in accordance with Article 7, except for sizing. The vent shall be sized in accordance with Section 18-29-916.2. The lowest point of the island fixture vent shall connect full size to the drainage system. The connection shall be to a vertical drain pipe or to the top half of a horizontal drain pipe. Clean-outs shall be provided in the island fixture vent to permit rodding of all vent piping located below the flood level rim of the fixtures. Rodding in both directions shall be permitted through a clean-out.
Loading...