Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
CHAPTER 18-11 RESERVED*
CHAPTER 18-13 RESERVED*
CHAPTER 18-14 BUILDING ENERGY USE BENCHMARKING
CHAPTER 18-27 RESERVED*
CHAPTER 18-28 MECHANICAL SYSTEMS*
CHAPTER 18-29 PLUMBING*
Article 1. Administration (18-29-101 et seq.)
Article 2. Definitions (18-29-201 et seq.)
Article 3. General Regulations (18-29-301 et seq.)
Article 4. Fixtures, Faucets and Fixture Fittings (18-29-401 et seq.)
Article 5. Water Heaters (18-29-501 et seq.)
Article 6. Water Supply and Distribution (18-29-601 et seq.)
Article 7. Sanitary Drainage (18-29-701 et seq.)
Article 8. Indirect/Special Waste (18-29-801 et seq.)
Article 9. Vents (18-29-901 et seq.)
18-29-901 General.
18-29-901.1 Scope.
18-29-901.2 Trap seal protection.
18-29-901.2.1 Venting required.
18-29-901.3 Chemical waste vent system.
18-29-901.4 Use limitations.
18-29-901.5 Tests.
18-29-901.6 Protection from freezing.
18-29-902 Materials.
18-29-902.1 Vents.
18-29-902.2 Sheet copper.
18-29-902.3 Sheet lead.
18-29-903 Vent Stacks and Stack Vents.
18-29-903.1 Main vent required.
18-29-903.2 Vent stack required.
18-29-903.3 Vent termination.
18-29-903.4 Vent connection at base.
18-29-903.5 Vent headers.
18-29-904 Vent Terminals.
18-29-904.1 Vent terminals required.
18-29-904.1.1 Roof extension unprotected.
18-29-904.1.2 Occupiable rooftop.
18-29-904.1.3 Reserved.
18-29-904.1.4 Sidewall vent terminal.
18-29-904.2 Frost closure.
18-29-904.3 Flashings.
18-29-904.4 Prohibited use.
18-29-904.5 Location of vent terminal.
18-29-904.6 Extension outside a structure.
18-29-905 Vent Connections and Grades.
18-29-905.1 Connection.
18-29-905.2 Grade.
18-29-905.3 Vent connection to drainage system.
18-29-905.4 Vertical rise of vent.
18-29-905.5 Height above fixtures.
18-29-905.6 Side inlet.
18-29-905.7 Vent for future fixtures.
18-29-906 Fixture Vents.
18-29-906.1 Distance of trap from vent.
18-29-906.2 Venting of fixture drains.
18-29-906.3 Crown vent.
18-29-907 Individual Vent.
18-29-907.1 Individual vent permitted.
18-29-908 Common Vent.
18-29-908.1 Individual vent as common vent.
18-29-908.2 Connection at the same level.
18-29-908.3 Connection of different levels.
18-29-909 Deliberately omitted.
18-29-910 Deliberately omitted.
18-29-911 Deliberately omitted.
18-29-912 Combination Drain and Vent System.
18-29-912.1 Type of fixtures.
18-29-912.2 Waste piping and trap.
18-29-912.2.1 Branches.
18-29-912.2.2 Sinks, lavatories, and other fixtures.
18-29-912.2.3 Long mains.
18-29-912.2.4 Floor drains.
18-29-912.3 Size.
18-29-913 Island Fixture Venting.
18-29-913.1 Limitation.
18-29-913.2 Vent connection.
18-29-913.3 Vent installation below the fixture flood level rim.
18-29-914 Relief Vents - Stacks of More Than 10 Branch Intervals.
18-29-914.1 Where required.
18-29-914.2 Size and connection.
18-29-915 Vents for Stack Offsets.
18-29-915.1 Vent for horizontal offset of drainage stack.
18-29-915.2 Upper section.
18-29-915.3 Lower section.
18-29-916 Vent Pipe Sizing.
18-29-916.1 Size of stack vents and vent stacks.
18-29-916.2 Vents other than stack vents or vent stacks.
18-29-916.3 Developed length.
18-29-916.4 Multiple branch vents.
18-29-916.4.1 Reserved.
18-29-916.5 Sump vents.
18-29-916.5.1 Sewage pumps and sewage ejectors other than pneumatic.
18-29-916.5.2 Pneumatic sewage ejectors.
18-29-917 Vents Not Required.
18-29-917.1 Not required.
18-29-918 Deliberately omitted.
Article 10. Traps, Separators and Interceptors (18-29-1001 et seq.)
Article 11. Storm Drainage (18-29-1101 et seq.)
Article 12. Swimming Pools and Other Swimming Facilities* (18-29-1201 et seq.)
Article 13. Referenced Standards
Appendix A Procedures for Calculating the Minimum Sizing of the Water Supply System
CHAPTER 18-30 RESERVED*
CHAPTER 18-31 RESERVED*
CHAPTER 18-32 RESERVED*
CHAPTER 18-36 REFERENCE STANDARDS*
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
18-29-906 Fixture Vents.
18-29-906.1 Distance of trap from vent.
   Each fixture trap shall have a protecting vent located so that the slope and the developed length in the fixture drain from the trap weir to the vent fitting are within the requirements set forth in Table 18-29-906.1.
   Exception: The developed length of the fixture drain from the trap weir to the vent fitting for self-siphoning fixtures, such as water closets, shall not be limited.
Table 18-29-906.1
Maximum Distance of Fixture Trap from Vent
 
Size of Trap (inches)
Size of Fixture Drain (inches)
Slope
(inch per foot)
Distance from Trap (feet)
1 1/4
1 1/2
1/4
5
1 1/2
1 1/2
1/4
5
1 1/2
2
1/4
5
2
2
1/4
5
3
3
1/8
5
4
4
1/8
5
 
(Amend Coun. J. 10-14-21, p. 37722, Art. IX, § 4)
18-29-906.2 Venting of fixture drains.
   The vent for a fixture drain, except where serving a fixture with integral taps, such as water closets, shall connect above the weir of the fixture trap being vented.
18-29-906.3 Crown vent.
   A vent shall not be installed within two pipe diameters of the trap weir.
18-29-907 Individual Vent.
18-29-907.1 Individual vent permitted.
   Each trap and trapped fixture is permitted to be provided with an individual vent. The individual vent shall connect to the fixture drain of the trap or trapped fixture being vented.
18-29-908 Common Vent.
18-29-908.1 Individual vent as common vent.
   An individual vent is permitted to vent two traps or trapped fixtures as a common vent. The traps or trapped fixtures being common vented shall be located on the same floor level.
18-29-908.2 Connection at the same level.
   Where the fixture drains being common vented connect at the same level, the vent connection shall be at the interconnection of the fixture drains.
Loading...