Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
CHAPTER 15-16 FIRE PROTECTION EQUIPMENT
ARTICLE I. FIRE PROTECTION (15-16-010 et seq.)
ARTICLE II. FIRE PROTECTION EQUIPMENT (15-16-170 et seq.)
PART 1. STANDARD SPRINKLER SYSTEMS (15-16-170 et seq.)
PART 2. STANDARD FIRE EXTINGUISHERS (15-16-620 et seq.)
PART 3. STANDARD INSIDE STANDPIPE SYSTEMS (15-16-710 et seq.)
15-16-710 Definition of system.
15-16-720 Where standpipe system required.
15-16-730 Other definitions.
15-16-740 Permit fees.
15-16-750 Installation certification.
15-16-760 Types of systems.
15-16-770 Sources of water supply.
15-16-780 Fire pumps.
15-16-790 Use for other services.
15-16-800 Fire pump requirements.
15-16-810 Pumps supplied from city main.
15-16-820 Fire pump auxiliary equipment.
15-16-830 Pressure-control devices.
15-16-840 Pump suction piping.
15-16-850 Requirements for auxiliary drive.
15-16-860 Piping arrangement.
15-16-870 Piping design.
15-16-880 Piping drains.
15-16-890 Risers.
15-16-900 Arrangement of risers.
15-16-910 Location of risers.
15-16-920 Size of risers.
15-16-930 Fire department hose connections.
15-16-940 Hose valve design.
15-16-950 Hand hose connections.
15-16-960 Hand hose valve design.
15-16-970 Equipment at hose outlets.
15-16-971 Identification of hose valves.
15-16-980 Pressure reducing devices.
15-16-990 Domestic use prohibited.
15-16-1000 Multiple systems.
15-16-1010 Express risers.
15-16-1020 Siamese connections required.
15-16-1030 Check valves for siamese.
15-16-1040 Arrangement of siamese connections.
15-16-1050 Valves.
15-16-1060 Reserved.
15-16-1070 Test manifold and wall hydrants.
15-16-1080 Gauges.
15-16-1090 Painting and identification of pipe.
15-16-1100 Protection against freezing.
15-16-1110 Dry pipe system.
15-16-1115 Manual dry pipe system.
15-16-1120 Buildings under construction.
15-16-1130 Buildings being demolished.
15-16-1140 Alarms.
15-16-1150 Test method.
15-16-1160 Annual test required.
15-16-1170 Inspection.
15-16-1180 Retroactivity.
15-16-1190 Existing buildings.
PART 4. STANDARD FIRE ALARM SYSTEMS (15-16-1200 et seq.)
PART 5. SPRINKLER SYSTEMS - ADDITIONAL PROVISIONS (15-16-1520 et seq.)
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
15-16-1100  Protection against freezing.
   All portions of inside standpipe systems, normally filled with water and exposed to frost and freezing temperatures, shall be protected against freezing.
(Prior code §  91-91; Amend Coun. J. 10-30-96, p. 31261, § 1)
15-16-1110  Dry pipe system.
   A dry pipe system shall be permitted only in a building, or a portion of a building, which is unheated.
   The dry pipe system shall be isolated from the water supply, or from the wet portion of the system, if a combined wet and dry pipe system, by one or more dry pipe valves located at accessible points as near as practicable to tin dry system, adequately protected against mechanical injury and against freezing; piping shall be arranged so that each standpipe riser shall be provided with an independent dry pipe valve.
   The valves shall automatically control the flow of water; they shall be constructed and installed so that under normal conditions, the portion of the piping in unheated spaces will remain dry. The operation of a hose valve will permit water to flow into the piping to supply water at the hose valve.
   An instruction sheet giving full directions for the maintenance and operation of the dry pipe valve and the safe minimum and maximum air pressure to be maintained on the dry pipe valve shall be permanently posted in a conspicuous place near each dry pipe valve. A permanent sign shall be posted at each hose valve on a dry standpipe system reading “DRY STANDPIPE – AIR UNDER PRESSURE”.
(Prior code §  91-92; Amend Coun. J. 10-30-96, p. 31261, § 1)
15-16-1115  Manual dry pipe system.
   A manual dry pipe system shall be permitted only as provided in Section 15-16-090(a)(5).
   A manual dry pipe system shall comply with Sections 15-16-870 through 15-16-890, 15-16-920 through 15-16-940, 15-16-971, and 15-16-1020 through 15-16-1040, except that no hose connection shall be required above the roof.
   A permanent sign shall be posted at each hose valve on a manual dry standpipe system and at the Fire Department connection reading “MANUAL DRY STANDPIPE.”
(Added Coun. J. 1-23-19, p. 94952, Art. II, § 3)
15-16-1120  Buildings under construction.
   For all buildings requiring a standpipe system, there shall be installed during construction a standpipe system which will protect the building during construction. The standpipe shall be installed when the building height reaches 80 feet. When the height of the building reaches 300 feet, fire pumps shall be installed and in service. This may be part of the permanent installation or may be an independent temporary system. If a temporary system, it shall consist of a main to which shall be connected not less than one-half the number of risers required for the permanent system and supplied through not less than one-half the number of siamese connections located where easily accessible with a check valve at each siamese and risers carried up through the building provided with two and one-half inch valves with fire department thread located in each story. These connections shall be accessible and protected with non-corrodible lugged caps attached to the riser with a chain not less than eight inches long. Outlets shall be in accessible locations and installed so that hose can be attached without kinking or bending.
   In buildings under construction the standpipe risers shall be extended so that the top hose connection is not more than two floors below the highest construction level. Risers shall be capped and kept closed at the top.
(Prior code §  91-93; Amend Coun. J. 10-30-96, p. 31261, § 1)
15-16-1130  Buildings being demolished.
   In all buildings or structures which are being reduced in height, wrecked or demolished and which are equipped with inside standpipe systems, the work of demolition shall proceed in such a manner that the systems will be maintained in an operative condition with the top of the risers not more than two stories below the top of the main structural supports of the building, or until the structural supports have leached a height of less than 40 feet above the street grade.
   Siamese connections shall not be removed until the lowest section of the risers has been removed.
(Prior code §  91-94; Amend Coun. J. 10-30-96, p. 31261, § 1)
15-16-1140  Alarms.
   Each standpipe shall be provided with a flow indicating device connected to operate a local alarm sounding device inside the main lobby at the fire command panel.
(Prior code §  91-95; Amend Coun. J. 10-30-96, p. 31261, § 1)
15-16-1150  Test method.
   Each new fire pump shall be given an acceptance test for one hour and shall deliver its rated capacity at the required speed and net pressure. Pumps rated at less than 1,500 gpm shall deliver 150 percent of the rated capacity at 65 percent of its rated pressure. The test shall not cause the bearings in the pump or on its motor, engine or turbine to become excessively heated. On electric driven fire pumps, there shall be no increase in the temperature of the electric wiring, electric windings of the motor and electric current carrying devices on the control panel other than as noted on the ratings of the various equipment.
   Automatic operation of the fire pump shall be verified by a pressure drop in the system. The test shall include manual starting and stopping of the pump.
   All electric wiring to the fire pump motor including the controller, emergency power supply, and pressure maintenance pump shall be completed prior to the acceptance test. The pressure at the intake side of the pump shall not be less than five pounds per square inch under any flow rate.
   An acceptance test shall be performed on any pump in which the impeller is replaced or repaired.
   All such tests shall be performed by an independent contractor licensed under the Illinois Fire Sprinkler Contractor Licensing Act in the presence of the fire commissioner.
(Prior code § 91-96; Amend Coun. J. 10-30-96, p. 31261, § 1; Amend Coun. J. 5-18-16, p. 24131, § 129)
15-16-1160  Annual test required.
   An annual test shall be made of each fire pump during which time water shall be discharged from the highest hose outlet of each riser. At least one riser shall be flowed for five minutes. Each fire pump shall deliver its rated capacity at its rated pressure through a test manifold or wall hydrant for a period of at least ten minutes. All such tests shall be performed by an independent contractor licensed under the Illinois Fire Sprinkler Contractor Licensing Act in the presence of the fire commissioner. A fee of $31.50 for each 50 gallon pumping capacity per minute shall be charged for each fire pump tested, with a minimum fee of $315.00 for each fire pump tested. The aforestated fees shall not be assessed with respect to any building used solely as a school operated by the Chicago Board of Education.
(Prior code § 91-97; Amend Coun. J. 7-13-94, p. 53399; Amend Coun. J. 10-30-96, p. 31261, § 1; Amend Coun, J, 11-16-11, p. 13798, Art. VIII, § 3; Amend Coun. J. 5-18-16, p. 24131, § 130; Amend Coun. J. 11-14-18, p. 90376, Art. V, § 6)
15-16-1170  Inspection.
   It shall be the duty of the fire commissioner to cause an inspection to be made of all standpipe systems at least once every year by an independent contractor licensed under the Illinois Fire Sprinkler Contractor Licensing Act. Such inspections shall be schedule with, and may be overseen by or in the presence of, the fire commissioner. If such inspection discloses any violations of, or variation from, the requirements of this Code pertaining to standpipes or standpipe systems, or any defective conditions which would handicap the operation of the standpipe system, notice shall be sent to the owner or agent in control of the building containing such standpipe system to remove or correct such defective conditions within such time as shall be set forth in said notice. It shall be the duty of the building owner to pay the comptroller an inspection fee of $50.00 for each standpipe, other than a manual dry standpipe, inspected in connection with such annual inspection.
(Prior code § 91-98; Amend Coun. J. 12-15-92, p. 27387; Amend Coun. J. 10-30-96, p. 31261, § 1; Amend Coun. J. 11-16-11, p. 13798, Art. I, § 11; Amend Coun. J. 5-18-16, p. 24131, § 131; Amend Coun. J. 1-23-19, p. 94952, Art. II, § 4)
Loading...