Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
PART 4.  FIRE EXTINGUISHERS (15-16-160 et seq.)
15-16-160  General requirements.
   Standard fire extinguishers shall be provided in accordance with the provisions of Sections 15-16-620 to 15-16-680 of this Code inclusive.
(Prior code §  64-15)
ARTICLE II.  FIRE PROTECTION EQUIPMENT (15-16-170 et seq.)
PART 1.  STANDARD SPRINKLER SYSTEMS (15-16-170 et seq.)
15-16-170  Definition of system.
   A standard sprinkler system, for the purpose of this code, is hereby defined as an arrangement of piping installed in a building with outlets termed sprinklers distributed in such a manner that water can be discharged automatically in a spray directly from the sprinklers, for the purpose of extinguishing an incipient fire and protecting the building and its occupants and contents, with pumps, tanks and other equipment as necessary to provide an adequate supply of water to the sprinklers. Every sprinkler system required by this code shall comply with all the requirements hereinafter enumerated for such a system. Fire pumps, filling pumps, air compressors, sprinklers, hose and all equipment installed in connection with a standard sprinkler system shall be of a make, type and design which has been tested and listed by and which bears the label of a product testing laboratory which regularly tests fire protection equipment and conducts periodic inspection of the production of listed equipment or materials.
(Prior code §  91-1; Amend Coun. J. 10-30-96, p. 31216, § 1)