Skip to code content (skip section selection)
Compare to:
New York City Overview
The New York City Charter
The New York City Administrative Code
The Rules of the City of New York
THE RULES OF THE CITY OF NEW YORK
Title 1: Department of Buildings
Title 2: Board of Standards and Appeals
Title 3: Fire Department
Title 6: Department of Consumer and Worker Protection
Title 9: Procurement Policy Board Rules
Title 12: Franchise and Concession Review Committee
Title 15: Department of Environmental Protection
Chapter 1: Asbestos Control Program
Chapter 2: Engineering Criteria for Fossil Fuel Burning Boilers and Water Heaters
Chapter 3: Cessation of Operation and Removal and Sealing of Refuse Burning Equipment
Chapter 4: Certification of Gasoline Dispensing Sites and Transport Vehicles
Chapter 5: Criteria Used For Upgrading Existing Apartment House Incinerators
Chapter 6: Interpolation of Allowable Sound Levels For Motor Vehicles
Chapter 7: Tunneling
Chapter 8: Industrial Equipment
Chapter 9: Gas Fired Burner Installations
Chapter 10: Air Pollution Control Instruction in Fuel Burning Equipment Using Residual Fuel Oil and Refuse Burning Equipment
Chapter 11: Hazardous Substances Emergency Response
Chapter 12: Perchloroethylene Dry Cleaning Facilities
Chapter 13: Rules Pertaining to the Prevention of the Emission of Dust from Construction Related Activities
Chapter 14: Rules Concerning the Use of Ultra Low Sulfur Diesel Fuel and Emissions Control Technology in Nonroad Vehicles Used in City Construction
Chapter 15: Rules Concerning the Use of Ultra Low Sulfur Diesel Fuel and Emission Control Technology on City Motor Vehicles
Chapter 16: NYCDEP Rules for the Recreational Use of City Property*
Chapter 17: [Occupation or Use of New York City Property (Lands, Water Bodies, Reservoirs and Infrastructure) in the Counties of Delaware, Dutchess, Greene, Orange, Putnam, Schoharie, Sullivan, Ulster, and Westchester]
Chapter 18: Protection from Contamination, Degradation and Pollution of the New York City Water Supply and Its Sources
Chapter 19: Use of the Public Sewers
Chapter 19.1: Stormwater Management for Water Pollution Control
Chapter 20: Governing and Restricting the Use and Supply of Water
Chapter 21: Water Shortage Emergency Rules
Chapter 22: Withdrawal of Water from the New York City Water Supply System
Chapter 23: Construction of Private Sewers or Private Drains
Chapter 24: [Contamination of Tax Lot by Hazardous Materials or Hazardous Waste; Placement and Removal of an (E) Designation on Tax Lot in Connection with Zoning Map Amendment]
Chapter 25: Rules Concerning the Use of Emissions Control Technology on Sight-Seeing Buses
Chapter 26: Rules Concerning the Use of Ultra Low Sulfur Diesel Fuel and Emissions Control Technology on Vehicles That Transport Children to and from School
Chapter 27: Rules Concerning the Use of Ultra Low Sulfur Diesel Fuel and Emissions Control Technology On Solid Waste Vehicles
Chapter 28: Citywide Construction Noise Mitigation
Chapter 29: Commercial Music Noise Mitigation Rules
Chapter 30: Minimal Noise Impact Construction Activities
Chapter 31: Rule Governing House / Site Connections to the Sewer System
Chapter 32: Adjudications
Chapter 33: Sale of Tax Liens and Complaint Resolution
Chapter 34: [Air Pollution Control Code Fees]
Chapter 35: Voluntary Master Environmental Hazard Remediation Technician Registration Program
Chapter 36: Cure Period for Certain Air and Noise Code Violations
Chapter 37: Emission Reduction Technologies for Char Broilers
Chapter 38: Emissions Reduction Technologies for New Cook Stoves
Chapter 39: Engine Idling
Chapter 40: Rules Concerning the Registration of Emergency Generators [Repealed]
Chapter 41: Community Right-to-Know Regulations
Chapter 42: City Environmental Quality Review (CEQR) (City Planning and Department of Environmental Protection)
Chapter 43: Air Code Penalty Schedule
Chapter 44: Standard Test Procedures to Determine Smoke Emissions from Generators with an Output of 40 kw or More
Chapter 45: Abatement Orders
Chapter 46: Filming and Photography Authorized by the Department
Chapter 47: Noise Code Penalty Schedule
Chapter 48: Green Infrastructure Grant Program
Chapter 49: Spraying Insulating Material
Chapter 50: Registration of Other Emission Sources or Activities
Chapter 51: [Retrofit Technology in Heavy Duty Trade Waste Hauling Vehicles]
Chapter 52: After Hours Noise Complaints
Chapter 53: Air Asbestos Penalty Schedule
Chapter 54: Community Right-To-Know Law Penalty Schedule
Chapter 55: Stormwater Penalty Schedule
Chapter 56: Sewer Control Rules Penalty Schedule
Chapter 57: Rules Concerning Drilling and Excavation
Chapter 58: Notification of Mold Remediation
Chapter 59: Hazardous Substances Emergency Response Law Penalty Schedule
Chapter 60: Rulemaking Petitions
Chapter 61: Public Hearings Held Pursuant to Administrative Code § 24-110
Chapter 62: Emissions Reduction Technologies for Existing Cook Stoves
Chapter 63: Stationary Engines
Title 16: Department of Sanitation
Title 17: Business Integrity Commission
Title 19: Department of Finance
Title 20: Tax Appeals Tribunal
Title 21: Tax Commission
Title 22: Banking Commission
Title 24: Department of Health and Mental Hygiene
Title 25: Department of Mental Health and Retardation [Repealed]
Title 28: Housing Preservation and Development
Title 29: Loft Board
Title 30: Rent Guidelines Board
Title 31: Mayor's Office of Homelessness and Single Room Occupancy
Title 34: Department of Transportation
Title 35: Taxi and Limousine Commission
Title 38: Police Department
Title 38-A: Civilian Complaint Review Board
Title 39: Department of Correction
Title 40: Board of Correction
Title 41: Department of Juvenile Justice
Title 42: Department of Probation
Title 43: Mayor
Title 44: Comptroller
Title 45: Borough Presidents
Title 46: Law Department
Title 47: Commission on Human Rights
Title 48: Office of Administrative Trials and Hearings (OATH)
Title 49: Department of Records and Information Services
Title 50: Community Assistance Unit
Title 51: City Clerk
Title 52: Campaign Finance Board*
Title 53: Conflicts of Interest Board
Title 55: Department of Citywide Administrative Services
Title 56: Department of Parks and Recreation
Title 57: Art Commission
Title 58: Department of Cultural Affairs
Title 60: Civil Service Commission
Title 61: Office of Collective Bargaining
Title 62: City Planning
Title 63: Landmarks Preservation Commission
Title 66: Department of Small Business Services
Title 67: Department of Information Technology and Telecommunications
Title 68: Human Resources Administration
Title 69: Department of Aging
Title 70: In Rem Foreclosure Release Board
Title 71: Voter Assistance Commission
Title 72: Office of Emergency Management
Title 73: Civic Engagement Commission
Title 74: Community Hiring
Loading...
§ 37-04 Records.
   (a)   Recordkeeping. 
      (i)   Effective May 6, 2016, any person operating a new under-fired commercial char broiler or an existing or new chain-driven commercial char broiler used to cook 875 pounds or less of meat per week, must maintain records showing the amount of meat purchased per month.
      (ii)   Effective May 6, 2016, any person operating a new under-fired commercial char broiler or an existing or new chain-driven commercial char broiler used to cook more than 875 pounds of meat per week must maintain records regarding the date of installation, replacement and maintenance of any emissions control device installed to abate emissions from the char broiler.
      (iii)   For purposes of this subdivision, maintenance includes, but is not limited to, preventative maintenance, breakdown repair, and cleaning performed on the emissions control device. The records must include the date, time, and a brief description of the work.
   (b)   Retention of Records. All records required by this section must be retained for at least one year and must be made available to the department upon request.
(Added City Record 8/17/2016, eff. 9/16/2016)
§ 37-05 Certification of Emissions Control Devices.
   The manufacturer or owner of an emissions control device may seek department certification by submitting documentation from an independent testing laboratory that tests in accordance with an EPA accredited laboratory testing method that the emissions control device has been tested in accordance with the applicable procedures set forth in 15 RCNY § 37-06 and that such device meets the requirements of 15 RCNY § 37-02. Such documentation must be submitted in accordance with the requirements of 15 RCNY § 37-06(c). The department will maintain a list of approved certified emissions control devices for use with particular models of commercial char broilers on the department's website and will update the list periodically as necessary.
(Added City Record 8/17/2016, eff. 9/16/2016)
§ 37-06 Protocols for Testing Emissions Control Devices.
   (a)   Protocols for Testing Emissions Control Devices on Chain-Driven Commercial Char Broilers. 
      (i)   Laboratory testing must be performed on an emissions control device that is installed on a chain-driven commercial char broiler per manufacturer's specifications. ASTM International Standard Test Method F 2239-10 must be followed using heavy load cooking tests and careful attention must be given to the following specifications as set forth in greater detail in such test method:
         a.   The chain-driven commercial char broiler must be positioned such that a minimum of 6 inches is maintained between the edge of the hood and the vertical plane of the front and sides of the appliance.
         b.   The patties must consist of 18-22% fat by weight and 58-62% moisture. The patties must be shaped into 0.375 inch thick round patties of 5 inch diameter. The fat and moisture content of the patties must be verified in accordance with the laboratory procedures set forth in the Association of Official Analytical Chemists Official Actions 960.39 and 950.46B.
         c.   Patties must be loaded, cooked, and removed in accordance with Section 10 of ASTM International Standard Test Method F 2239-10 using heavy load conditions.
      (ii)   Emissions testing for filterable and condensable particulate matter must be performed following EPA Method 5, Appendix A-3 to 40 C.F.R. Part 60, or EPA Method 202, Appendix M to 40 C.F.R. Part 51, or South Coast Air Quality Management District Method 5.1. During each test, samples must be collected from the outlet of the control.
   (b)   Protocols for Testing Emissions Control Devices on Under-Fired Commercial Char Broilers. 
      (i)   Laboratory testing must be performed on an emissions control device that is installed on an under-fired commercial char broiler per manufacturer's specifications. ASTM International Standard Test Method F 1695-03 must be followed using heavy load cooking tests and careful attention must be given to the following specifications as set forth in greater detail in such test method:
         a.   The exhaust hood must have the capacity to operate at a nominal net exhaust ventilation rate of 400 cubic feet per minute (cfm) for each linear foot of active hood length. The hood must extend over the surface of the under-fired commercial char broiler by at least 6 inches in the front and sides.
         b.   The under-fired commercial char broiler must be warmed up for a minimum of 30 minutes before testing and the controls must be set to operate at a maximum temperature of 600 degrees Fahrenheit, with a cooking energy rate established at this setting.
         c.   Pure beef, finished grind hamburgers of 0.33 lbs each must be cooked on the under-fired commercial char broiler during testing. The patties must be shaped into 0.625 inch thick round patties of 5 inch diameter.
         d.   The patties must consist of 18 - 22% fat by weight and 58 - 62% moisture.
         e.   The fat and moisture content of the patties must be verified in accordance with the laboratory procedures set forth in the Association of Official Analytical Chemists Official Actions 960.39 and 950.46B.
         f.   Hamburger patties must be loaded, cooked, and removed in accordance with Section 10 of ASTM International Test Method F 1695-03 using heavy load conditions.
      (ii)   Emissions testing for filterable and condensable particulate matter must be performed following EPA Method 5, Appendix A-3 to 40 C.F.R. Part 60, or EPA Method 202, Appendix M to 40 C.F.R. Part 51, or South Coast Air Quality Management District Method 5.1. During each test, samples must be collected from the outlet of the control.
   (c)   Reporting. The results of the testing required by this section must be submitted on forms prescribed by the department available on the department's website and must include the following information:
      a.   Name and address of the manufacturer of the commercial char broiler, brand name, trade name, model number of the commercial char broiler, any accoutrements installed to enhance or support the operation of the emissions control device, the maximum air flow rate, and other relevant operating conditions during the test, as specified by the department.
      b.   A description of the emissions control device used on the commercial char broiler model being certified.
      c.   A statement that testing has been conducted in accordance with the requirements of this section.
(Added City Record 8/17/2016, eff. 9/16/2016)