Loading...
806.3 Reserved.
806.4 Reserved.
806.5 Foam plastic as trim.
Foam plastic used as trim shall comply with Section 2604.2 and shall not be permitted in occupancies other than Group R-3, within individual dwelling units of Group R-1 and R-2 occupancies, or unless approved in accordance with Section 2603.9.
806.6 Pyroxylin plastic.
Imitation leather or other material consisting of or coated with a pyroxylin or similarly hazardous base shall not be used in Group A occupancies.
806.7 Interior trim.
Material, other than foam plastic used as interior trim, shall have a minimum Class C flame spread index and maximum smoke-developed index when tested in accordance with ASTM E 84 or UL 723 as described in Section 803.1.1. Combustible trim, excluding handrails and guardrails, shall not exceed 10 percent of the specific wall or ceiling area in which it is attached.