Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
CHAPTER 14E-1 GENERAL
CHAPTER 14E-2 WIRING AND PROTECTION
CHAPTER 14E-3 GENERAL REQUIREMENTS FOR WIRING METHODS AND MATERIALS
14E-3-300 General requirements for wiring methods and materials.
14E-3-310 Conductors for general wiring.
14E-3-312 Cabinets, cutout boxes, and meter socket enclosures.
14E-3-314 Outlets, device, pull and junction boxes, conduit bodies; fittings; and handhole enclosures.
14E-3-320 Armored cable: Type AC.
14E-3-322 Flat cable assemblies: Type FC.
14E-3-324 Flat conductor cable: Type FCC.
14E-3-326 Integrated gas spacer cable: Type IGS.
14E-3-328 Medium voltage cable: Type MV.
14E-3-330 Metal-clad cable: Type MC.
14E-3-332 Mineral-insulated, metal-sheathed cable: Type MI.
14E-3-334 Nonmetallic-sheathed cable: Types NM, NMC, and NMS.
14E-3-336 Power and control tray cable: Type TC.
14E-3-338 Service-entrance cable: Type SE and USE.
14E-3-340 Underground feeder and branch-circuit cable: Type UF.
14E-3-342 Intermediate metal conduit: Type IMC.
14E-3-344 Rigid metal conduit: Type RMC.
14E-3-348 Flexible metal conduit: Type FMC.
14E-3-350 Liquidtight flexible metal conduit: Type LFMC.
14E-3-352 Rigid polyvinyl chloride conduit: Type PVC.
14E-3-353 High density polyethylene conduit: Type HDPE conduit.
14E-3-354 Nonmetallic underground conduit with conductors: Type NUCC.
14E-3-355 Reinforced thermosetting resin conduit: Type RTRC.
14E-3-356 Liquidtight flexible nonmetallic conduit: Type LFNC.
14E-3-358 Electrical metallic tubing: Type EMT.
14E-3-360 Flexible metallic tubing: Type FMT.
14E-3-362 Electrical nonmetallic tubing: Type ENT.
14E-3-366 Metallic auxiliary gutters.
14E-3-368 Busways.
14E-3-370 Cablebus.
14E-3-372 Cellular concrete floor raceways.
14E-3-374 Cellular metal floor raceways.
14E-3-376 Metal wireways.
14E-3-378 Nonmetallic wireways.
14E-3-380 Multi-outlet assembly.
14E-3-382 Nonmetallic extensions.
14E-3-384 Strut-type channel raceway.
14E-3-386 Surface metal raceways.
14E-3-388 Surface nonmetallic raceways.
14E-3-390 Underfloor raceways.
14E-3-392 Cable trays.
14E-3-393 Low-voltage suspended ceiling power distribution systems.
14E-3-394 Concealed knob-and-tube wiring.
14E-3-396 Messenger-supported wiring.
14E-3-398 Open wiring on insulators.
14E-3-399 Outdoor overhead conductors over 1,000 volts.
CHAPTER 14E-4 EQUIPMENT FOR GENERAL USE
CHAPTER 14E-5 SPECIAL OCCUPANCIES
CHAPTER 14E-6 SPECIAL EQUIPMENT
CHAPTER 14E-7 SPECIAL CONDITIONS
CHAPTER 14E-8 COMMUNICATIONS SYSTEMS
CHAPTER 14E-9 TABLES
CHAPTER 14E-10 INFORMATIVE ANNEXES
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
14E-3-320 Armored cable: Type AC.
The provisions of Article 320 of NFPA 70 are adopted by reference with the following modifications:
1.   Revise section 320.10 to read:
"Uses Permitted. Type AC cable shall be permitted to be installed as specified in 320.10(A) or (B).
(A)   Existing Installations. Except where otherwise specified in this Code and where not subject to physical damage, listed Type AC cable with listed fittings and not exceeding 7.62 m (25 ft) in length between junction boxes shall be permitted to be installed for branch circuits in concealed work fished into existing walls, partitions, floors, or hard surface ceilings where other work does not require or include removal of the existing finished surface.
(B)   Exposed Work. For exposed work only under the following conditions:
(1)   In lengths not more than 1.83 m (6 ft), at terminations where flexibility is necessary;
(2)   In lengths not more than 1.83 m (6 ft) in accessible, but not habitable, attics and roof spaces where installed in accordance with 320.12;
(3)   In lengths not greater than 1.83 m (6 ft), below the basement ceiling joists where it is necessary to connect a cabinet or junction box."
2.   Revise section 320.12 to read:
"Uses Not Permitted. Type AC cable shall not be used for any installation not permitted in 320.10."
14E-3-322 Flat cable assemblies: Type FC.
The provisions of Article 322 of NFPA 70 are not adopted.
14E-3-324 Flat conductor cable: Type FCC.
The provisions of Article 324 of NFPA 70 are adopted by reference without modification.
14E-3-326 Integrated gas spacer cable: Type IGS.
The provisions of Article 326 of NFPA 70 are not adopted.
14E-3-328 Medium voltage cable: Type MV.
The provisions of Article 328 of NFPA 70 are adopted by reference without modification.
14E-3-330 Metal-clad cable: Type MC.
The provisions of Article 330 of NFPA 70 are adopted by reference with the following modifications:
1.   Revise section 330.10 to read:
"Uses Permitted.
(A)   Existing Installations. Except where otherwise specified in this Code and where not subject to physical damage, listed Type MC cable with listed fittings and not exceeding 7.62 m (25 ft) in length between junction boxes shall be permitted for branch circuits in concealed work fished into existing walls, partitions, floors, or hard surface ceilings where other work does not require or include removal of the existing finished surface.
(B)   Exposed Work. For exposed work only under the following conditions:
(1)   In lengths not more than 1.83 m (6 ft), at terminations where flexibility is necessary;
(2)   In lengths not greater than 1.83 m (6 ft) in accessible, but not habitable, attics and roof spaces where installed in accordance with 320.23;
(3)   In lengths not greater than 1.83 m (6 ft), below the basement ceiling joists where it is necessary to connect a cabinet or junction box."
2.   Revise section 330.12 to read:
"Uses Not Permitted. Type MC cable shall not be used for any installation not permitted in 330.10."
14E-3-332 Mineral-insulated, metal-sheathed cable: Type MI.
The provisions of Article 332 of NFPA 70 are adopted by reference without modification.