§ 2.05 RESIDENTIAL DESIGN STANDARDS.
   Any residential , including and not located in , shall be or constructed only if in compliance with the following residential design standards.
   A.   General requirements. 
      1.   Area and regulations. Any residential , including any unit, shall comply with the minimum floor area requirements specified for the where such is located. shall comply with all regulations normally required for site-built housing in the in which it is located, unless specifically indicated otherwise herein.
      2.   Foundation. Any residential , including a , shall be placed on a permanent foundation to form a complete enclosure under the exterior walls. The foundation shall be constructed in accordance with the adopted building code of the . A shall be securely anchored to its foundation in order to prevent displacement during windstorms. The wheels, tongue and hitch assembly, and other towing appurtenances, shall be removed before attaching a to its permanent foundation.
      3.   Other regulations. Residential shall be constructed in compliance with applicable state, federal, or local laws or ordinances, including the Michigan State Construction Code. shall comply with the most recent regulations specified by the United States Department of Housing and Urban Development, Manufactured Home Construction and Safety Standards (24 CFR 3280), as amended.
      4.   . No , including , shall be located within a 100-year .
      5.   Use.  and other shall be used only for the purposes permitted in the in which they are located.
      6.   Attachments. Any exterior attachments or extensions onto a , such as entry steps and storage , shall comply with the adopted building code of the .
   B.   Requirements applicable to . or units outside of after the effective date of this Ordinance shall comply with the general requirements set forth previously in § 2.05A. and with the following regulations.
      1.   Design features. The design and position of windows and other features of and , including exterior wall colors and color combinations, shall be similar to site-built homes within 1,200 feet of the property boundaries. If no more than one site-built is presently located within 1,200 feet of the proposed location, then the or shall be compared to the nearest 50 site-built homes.
      2.   Roof pitch. The pitch of the main roof shall have a minimum vertical rise of one foot for each four feet of horizontal run, and the minimum distance from the eaves to the ridge shall be ten feet, except where the specific housing design dictates otherwise (i.e., French provincial, Italianate, etc.). The roof shall be finished with a type of shingle or other material that is commonly used in standard on-site residential construction in the vicinity.
      3.   Exterior materials. The exterior siding of a or shall consist of materials that are generally acceptable for site-built housing in the vicinity, provided that the reflection from such exterior surface shall be no greater than from white semi-gloss exterior enamel, and provided further that any such exterior is comparable in composition, appearance, and durability to the exterior siding commonly used in standard residential construction.
      4.   Dimensions. The dimensions and placement of or shall be comparable to typical dimensions and placement of site-built housing in the vicinity. Therefore, a or shall be located on the so that the minimum width of the front elevation is no less than 34 feet and the minimum dimension along any side or rear elevation is no less than 24 feet. If there are any extensions or additions off of the front of the or , the minimum width of any such secondary front elevation shall be 24 feet. Such dimensions shall be measured from the outer extremities and shall include additions to the main body of the or , such as living or recreation , garages, carports, utility , and the like, the front portions of which are within 10 feet of the front of the main body of the or .
      5.   Roof overhang.  and shall be designed with either a roof overhang of not less than six inches on all sides or with window sills and roof drainage systems to concentrate roof drainage at collection points along the sides of the .
      6.   Exterior doors.  and shall have not less than two exterior doors which shall not be located on the same side of the . Where required because of a difference in elevation, all exterior doors shall be provided with steps that are permanently attached to the .
(Ord. passed 7-9-2013)