Skip to code content (skip section selection)
Compare to:
New York City Overview
The New York City Charter
The New York City Administrative Code
NEW YORK CITY ADMINISTRATIVE CODE
Title 1: General Provisions
Title 2: City of New York
Title 3: Elected officials
Title 4: Property of the City
Title 5: Budget; Capital Projects
Title 6: Contracts, Purchases and Franchises
Title 7: Legal Affairs
Title 8: Civil Rights
Title 9: Criminal Justice
Title 10: Public Safety
Title 11: Taxation and Finance
Title 12: Personnel and Labor
Title 13: Retirement and Pensions
Title 14: Police
Title 15: Fire Prevention and Control
Title 16: Sanitation
Title 16-A: [Commercial Waste Removal]
Title 16-B: Commercial Waste Zones
Title 17: Health
Title 18: Parks
Title 19: Transportation
Title 20: Consumer and Worker Protection
Title 20-A: [Shipboard Gambling]
Title 21: Social Services
Title 21-A: Education
Title 22: Economic Affairs
Title 23: Communications
Title 24: Environmental Protection and Utilities
Title 25: Land Use
Title 26: Housing and Buildings
Title 27: Construction and Maintenance
Title 28: New York City Construction Codes
Title 29: New York City Fire Code
Title 30: Emergency Management
Title 31: Department of Veterans' Services
Title 32: Labor and Employment
Title 33: Investigations
Title 34: Racial Equity
Appendix A: Unconsolidated Local Laws
The Rules of the City of New York
THE RULES OF THE CITY OF NEW YORK
Title 1: Department of Buildings
Title 2: Board of Standards and Appeals
Title 3: Fire Department
Title 6: Department of Consumer and Worker Protection
Title 9: Procurement Policy Board Rules
Title 12: Franchise and Concession Review Committee
Title 15: Department of Environmental Protection
Title 16: Department of Sanitation
Title 17: Business Integrity Commission
Title 19: Department of Finance
Title 20: Tax Appeals Tribunal
Title 21: Tax Commission
Title 22: Banking Commission
Title 24: Department of Health and Mental Hygiene
Title 25: Department of Mental Health and Retardation [Repealed]
Title 28: Housing Preservation and Development
Title 29: Loft Board
Title 30: Rent Guidelines Board
Title 31: Mayor's Office of Homelessness and Single Room Occupancy
Title 34: Department of Transportation
Title 35: Taxi and Limousine Commission
Title 38: Police Department
Title 38-A: Civilian Complaint Review Board
Title 39: Department of Correction
Title 40: Board of Correction
Title 41: Department of Juvenile Justice
Title 42: Department of Probation
Title 43: Mayor
Title 44: Comptroller
Title 45: Borough Presidents
Title 46: Law Department
Title 47: Commission on Human Rights
Title 48: Office of Administrative Trials and Hearings (OATH)
Title 49: Department of Records and Information Services
Title 50: Community Assistance Unit
Title 51: City Clerk
Title 52: Campaign Finance Board*
Title 53: Conflicts of Interest Board
Title 55: Department of Citywide Administrative Services
Title 56: Department of Parks and Recreation
Title 57: Art Commission
Title 58: Department of Cultural Affairs
Title 60: Civil Service Commission
Title 61: Office of Collective Bargaining
Title 62: City Planning
Title 63: Landmarks Preservation Commission
Title 66: Department of Small Business Services
Title 67: Department of Information Technology and Telecommunications
Title 68: Human Resources Administration
Title 69: Department of Aging
Title 70: In Rem Foreclosure Release Board
Title 71: Voter Assistance Commission
Title 72: Office of Emergency Management
Title 73: Civic Engagement Commission
Title 74: Community Hiring
Loading...
§ 27-773 Definitions.
For definitions to be used in the interpretation of this subchapter, see subchapter two of this chapter.
§ 27-774 Plans.
For the requirements governing the filing of plans and the work to be shown on plans, see subchapter one of this chapter.
§ 27-775 Permits.
For the requirements governing equipment work permits and equipment use permits, see subchapter one of this chapter.
§ 27-776 General requirements.
   (a)   Ventilation. The minimum quantities of air and other requirements for the ventilation of habitable and occupiable rooms shall be as required by subchapter twelve of this chapter, and for the ventilation of special uses and occupancies by subchapters seven and eight of this chapter.
   (b)   Noise control. Noise control requirements for mechanical equipment shall be as required by subchapter twelve of this chapter.
   (c)   Safety. All systems, equipment, and materials including any devices, apparatus, piping work, sheet metal work, insulation work, and supports therefor, used as part of or in connection with installations governed by this subchapter, shall be designed, installed, located, and operated so that they will not create an immediate or potential danger to life or impair public health or welfare. No piping of any kind, with the exception of piping required or, permitted under subchapter seventeen of this chapter, shall be permitted within a stair enclosure. Ducts protected in accordance with the requirements of this subchapter, which do not reduce the required clearances of a stair enclosure, are permissible.
   (d)   Openings. No openings for outdoor exhaust air discharges, air intakes, or reliefs from equipment shall be located and constructed so as to:
      (1)   Interfere with the proper functioning of other openings in the same building or in adjoining buildings.
      (2)   Interfere unreasonably with the occupants of the same building or adjoining buildings or with the general public.
      (3)   Create a fire or health hazard.
§ 27-777 Construction.
The construction, installation, and alteration of systems for providing mechanical ventilation, air conditioning, air cooling, air heating, and refrigeration, shall be in accordance with the following:
   (a)   Air conditioning and ventilating systems for all occupancies shall be constructed in accordance with the provisions of reference standard RS 13-1. In addition, equipment used for air conditioning systems shall be constructed, installed and altered in accordance with the provisions of reference standards RS 13-7 through 13-15. Where any conflicts arise between the electrical provisions of the foregoing reference standards and the New York city electrical code, the provisions of the latter shall govern.
   (b)   Air conditioning systems for one and two family dwellings, for one story buildings four thousand square feet or less in gross floor area provided ducts do not penetrate fire divisions, and for buildings classified in mercantile occupancy group C, twenty-five hundred square feet or less in gross floor area shall be constructed and installed in accordance with the provisions of reference standard RS 13-4. Also see article eleven of subchapter fourteen of this chapter.
   (c)   Exhaust systems for cooking spaces requiring mechanical ventilation in accordance with the provisions of subchapter twelve of this chapter, except kitchens located within dwelling units, shall be installed as provided in reference standard RS 13-2.
   (d)   Restaurant cooking equipment shall be provided with a means of ventilating such equipment constructed in accordance with the provisions of reference standard RS 13-3, provided however that restaurant cooking equipment installed for periodic cooking use other than commercial only, in community rooms of multiple dwellings, firehouses and other low hazard occupancies as determined by the commissioner may be provided with a means of ventilation constructed in accordance with the provisions of reference standard RS 13-1.
   (e)   Air blower and exhaust systems, where required for the removal or conveying of dust, vapor, or other impurities, shall be installed in accordance with the provisions of reference standard RS 13-5.
   (f)   Refrigeration systems shall be constructed, installed, and altered in accordance with the provisions of reference standard RS 13-6.
   (g)   The utilization of city water in air conditioning and refrigeration systems shall be subject to the requirements of reference standard RS-16.
§ 27-777.1 Smoke control requirements.
   (a)   In all buildings classified in occupancy group C, D, E, F, G, H, J-1 or J-2:
      (1)   Ventilation systems supplying different occupancy groups shall not be interconnected, provided however that a ventilation system may serve two occupancy groups located on the same floor when the accessory use occupies less than twenty per cent of the floor area occupied by the principal use.
      (2)   Ventilation systems supplying corridors shall not be interconnected with systems serving other spaces, except that this requirement shall not apply to floors used exclusively as office space in buildings classified in occupancy group E which are fully sprinklered.
      (3)   A ventilation system supplying any part of a means of egress shall not be interconnected with any other ventilation system.
      (4)   A ventilation system supplying public areas and assembly spaces shall have smoke detecting devices that will shut down the system upon detecting smoke.
      (5)   In buildings classified in occupancy group J-2, ventilation systems supplying individual apartments shall not be directly connected with any other ventilation system.
      (6)   Except in buildings classified in occupancy group J-2, and as otherwise provided in section 27-343 of article five of subchapter five of this chapter, either a combined heat and smoke damper or independent heat and smoke dampers shall be installed at any penetration of construction required to have a fire-resistance rating.
   (b)   In all buildings classified in occupancy group C, D, E, F, G, H or J-1, there shall be provided a system of mechanical means of sufficient capacity to exhaust six air changes per hour or 1 cfm/sq. ft., whichever is greater, from the largest floor in the building, using either dedicated fan equipment or the building ventilation system arranged to shut down automatically with manual override capability to exhaust one floor at a time through a roof or an approved location on an exterior wall other than a lot line wall.
§ 27-777.2 Ventilation in existing J-1 buildings.
In any existing building classified in occupancy group J-1, either seventy-five feet or more in height or containing thirty or more sleeping rooms:
   (a)   Where a corridor or space above a ceiling in a corridor is being used on or after February first, nineteen hundred eighty-four to furnish direct ventilation to a sleeping room or suite, such use shall, unless continued use is permitted by the commissioner, be discontinued by closing all openings between the corridor and sleeping room with construction having a fire-resistance rating equal to the construction in which the opening occurs. When continued use of corridor spaces as a plenum is permitted, smoke detecting devices shall be installed in accordance with the requirements of section 27-981 of article six of subchapter seventeen of this chapter and activation of any two detectors on a floor shall cause closure of all openings to that floor and shut-off of ventilation service to the floor.
   (b)   All corridors and other public areas not provided with natural ventilation meeting the requirements of section 27-761 of article eight of subchapter twelve of this chapter shall be provided with manual smoke purging by means of existing ventilation systems.
   (c)   The requirements of this section shall be complied with on or before April first, nineteen hundred eighty-seven.
Loading...