Skip to code content (skip section selection)
Compare to:
New York City Overview
The New York City Charter
The New York City Administrative Code
The Rules of the City of New York
THE RULES OF THE CITY OF NEW YORK
Title 1: Department of Buildings
Title 2: Board of Standards and Appeals
Title 3: Fire Department
Title 6: Department of Consumer and Worker Protection
Title 9: Procurement Policy Board Rules
Title 12: Franchise and Concession Review Committee
Title 15: Department of Environmental Protection
Title 16: Department of Sanitation
Title 17: Business Integrity Commission
Title 19: Department of Finance
Title 20: Tax Appeals Tribunal
Title 21: Tax Commission
Title 22: Banking Commission
Title 24: Department of Health and Mental Hygiene
Title 25: Department of Mental Health and Retardation [Repealed]
Title 28: Housing Preservation and Development
Title 29: Loft Board
Title 30: Rent Guidelines Board
Title 31: Mayor's Office of Homelessness and Single Room Occupancy
Title 34: Department of Transportation
Title 35: Taxi and Limousine Commission
Title 38: Police Department
Title 38-A: Civilian Complaint Review Board
Title 39: Department of Correction
Title 40: Board of Correction
Title 41: Department of Juvenile Justice
Title 42: Department of Probation
Title 43: Mayor
Title 44: Comptroller
Title 45: Borough Presidents
Title 46: Law Department
Title 47: Commission on Human Rights
Title 48: Office of Administrative Trials and Hearings (OATH)
Title 49: Department of Records and Information Services
Title 50: Community Assistance Unit
Title 51: City Clerk
Title 52: Campaign Finance Board*
Title 53: Conflicts of Interest Board
Title 55: Department of Citywide Administrative Services
Title 56: Department of Parks and Recreation
Title 57: Art Commission
Title 58: Department of Cultural Affairs
Title 60: Civil Service Commission
Title 61: Office of Collective Bargaining
Title 62: City Planning
Title 63: Landmarks Preservation Commission
Title 66: Department of Small Business Services
Title 67: Department of Information Technology and Telecommunications
Title 68: Human Resources Administration
Title 69: Department of Aging
Title 70: In Rem Foreclosure Release Board
Title 71: Voter Assistance Commission
Title 72: Office of Emergency Management
Title 73: Civic Engagement Commission
Title 74: Community Hiring
Loading...
105.3.9 Compliance with the requirements of the construction codes and Electrical Code.
The commissioner may require that the applicant for a permit or renewal thereof demonstrate, by submission of a certificate of occupancy or other authorization or approval issued by the Department of Buildings, that the building, structure or premises or portion thereof used for the manufacture, storage, handling or use of flammable or combustible liquids, combustible materials or hazardous materials, and all operations or facilities subject to this code, are designed, constructed and occupied in accordance with the certificate of occupancy, the construction codes and the Electrical Code.
105.3.9.1 Department of Buildings required approval.
No permit shall be issued when work requires the approval of the Commissioner of Buildings in connection with a material, operation or facility unless proof is submitted to the department that such work has been approved by the Commissioner of Buildings.
105.4 Design and installation documents.
Design and installation documents required to be submitted to the department pursuant to the provisions of this code, the rules or the construction codes, including but not limited to those set forth below, or as directed by the commissioner to demonstrate or document that a device, equipment, system, operation or facility regulated by this code is designed and installed in accordance with this code, shall be submitted in accordance with this section. Such submissions shall be reviewed by the department for compliance with the requirements of this code, the rules and other applicable laws, rules and regulations enforced by the department. The time limitations for approval of design and installation documents and for deeming such submissions abandoned shall be as set forth in FC 105.2.3 and 105.2.4.
   Aerosol products storage facilities:
      1.   General purpose warehouses (FC 2804 FC 5104).
      2.   Aerosol warehouses (FC 2804 FC 5104).
      3.   Liquid storage rooms (FC 2804 FC 5104).
      4.   Liquid warehouses (FC 2804 FC 5104).
      5.   Outdoor storage (FC 2805 FC 5105).
      6.   Retail display (FC 2806 FC 5106).
   Aircraft fueling systems (FC 2006).
   Ammonia diffusion systems for refrigerating systems using ammonia refrigerant (FC 606).
   Automated Parking Garage (FC 611).
   Auxiliary radio communication (ARC) systems, fire department in-building (FC 510).
   Cellulose nitrate film storage facilities (FC 306).
   Combustible fibers storage facilities:
      1.   Loose fiber storage (FC 3704).
      2.   Baled fiber storage (FC 3705).
   Combustible material storage (FC 315).
   Commercial cooking system fire extinguishing systems (FC 904).
   Corrosive materials systems and facilities:
      1.   Storage (FC 5404).
      2.   Handling and use (FC 5405).
   Cryogenic fluids systems and facilities:
      1.   Storage (FC 5503 and 5504).
      2.   Handling and use (FC 5503 and 5505).
      3.   Liquefied natural gas facilities (FC 5506).
   Distilleries (FC 4004 and 4005).
   Dry cleaning systems using Class II and III solvents (FC 2107).
   Emergency alarms (FC 908):
      1.   Flammable alcohol vapor (FC 4003).
      2.   Gaseous hydrogen (FC 5808).
      3.   Hazardous materials (FC 5004 and 5005).
      4.   Lighter-than-air motor fuels (FC 2308, 2309 and 2311).
      5.   Medical gases (FC 5306).
      6.   Flammable gases distribution piping operating above 15 psig (FC Table 908.1).
      7.   Ozone gas (FC 6005).
      8.   Refrigerants (FC 606).
      9.   Toxic/highly toxic materials (FC 6004).
   Energy storage systems, stationary (FC 608.6).
   Explosion control systems for certain hazardous materials and special uses (FC 911).
   Explosion (dust) protection systems for combustible metals, metal powders, metal dusts and sulfur (FC 2204).
   Explosives (FC 5604).
   Facilities in which a fumigant or insecticidal fogger are designed to be used in a stationary installation (FC 2603).
   Fire alarm systems and fire command centers (FC 907 and Sections 403, 907 and 911 of the Building Code).
   Fire apparatus access roads and security gates installed across such roads (FC 503).
   Fire extinguishing systems (sprinkler systems listed separately):
      1.   Aerosol (FC 904).
      2.   Carbon dioxide (FC 904).
      3.   Clean agent (FC 904).
      4.   Dry chemical (FC 904).
      5.   Foam (FC 904).
      6.   Halon (modification of lawfully existing installations) (FC 904).
      7.   Water mist (FC 904).
      8.   Wet chemical (FC 904).
   Fixed guideway transit and passenger rail systems (FC 321):
      1.   Emergency ventilation systems.
      2.   Emergency voice communication systems.
      3.   Means of egress.
      4.   Standpipe systems and other fire protection systems.
   Flammable and combustible liquid systems and facilities:
      1.   Piping, equipment, tanks, plants, terminals, fuel-dispensing facilities and similar facilities where flammable and combustible liquids are manufactured, stored, handled or used, including dispensing (FC 5704).
      2.   Group M occupancy wholesale and retail sales uses (FC 5704).
      3.   Liquid storage rooms (FC 5704).
      4.   Liquid storage warehouses (FC 5704).
      5.   Outdoor storage (FC 5704).
      6.   Bulk plants and terminals (FC 5706).
   Flammable gas systems and facilities:
      1.   Storage (FC 5804).
      2.   Handling and use (FC 5805).
      3.   CNG storage in portable containers (FC 5811).
      4.   Methane gas recovery from landfills (FC 5809).
      5.   Compressing of a flammable gas, including piped natural gas, to a pressure exceeding 6 psig (41.4 kPa) (FC Chapter 58).
      6.   Hydrogen fuel gas rooms (FC 5808).
   Flammable solid systems and facilities:
      1.   Storage (FC 5904).
      2.   Handling and use (FC 5905).
   Flammable/combustible spraying, dipping or powder-coating systems and facilities:
      1.   Spray booths (spray finishing) (FC 2404).
      2.   Spray rooms (spray finishing) (FC 2404).
      3.   Dip tanks (FC 2405).
      4.   Spray booths (powder coating) (FC 2406).
      5.   Spray rooms (powder coating) (FC 2406).
      6.   Limited spraying space (FC 2404).
   Flaring systems for refrigerating systems using flammable or toxic or highly toxic refrigerants (FC 606).
   Hazardous materials systems and facilities (FC 5003, 5004 and 5005) (applicable to compressed gases, corrosive materials, cryogenic fluids, explosives, flammable and combustible liquids, flammable gases, flammable solids, highly toxic and toxic materials, LPG, organic peroxides, oxidizers, pyrophoric materials, unstable (reactive) materials and water-reactive solids and liquids):
      1.   Tanks (FC 5003).
      2.   Piping, tubing, valves and fittings (FC 5003).
      3.   Highly toxic and toxic compressed gas rooms (FC 5003).
   Highly toxic and toxic materials systems and facilities:
      1.   Storage, handling and use of highly toxic and toxic solids and liquids (FC 6003).
      2.   Storage, handling and use of highly toxic and toxic compressed gases (FC 6004).
      3.   Ozone gas generators (FC 6005).
   High-piled combustible storage areas (FC 3201).
   Industrial furnaces (FC 3001).
   LPG (FC 6101).
   Marina fire protection systems (FC 3605).
   Medical gases:
      1.   Storage and piping systems (FC 5306).
   Motor fuel dispensing facilities and repair garages (FC 2301):
      1.   Fleet motor fuel-dispensing facilities.
      2.   Full-service motor fuel-dispensing facilities.
      3.   Self-service motor fuel-dispensing facilities.
      4.   Repair garages for vehicles fueled by lighter-than-air motor fuels.
   Natural gas distribution piping systems designed for or operated at 15 psig (103 kPa gauge) or greater (Fuel Gas Code).
   Nonflammable compressed gases systems and facilities (FC 5303).
   Organic coating manufacturing process facilities (FC 2905).
   Organic peroxides storage and facilities:
      1.   Storage (FC 6204).
      2.   Handling and use (FC 6205).
   Oxidizer systems and facilities:
      1.   Storage (FC 6304).
      2.   Handling and use (FC 6305).
   Oxygen-fuel gas systems (FC 3501 and 3509).
   Private fire hydrant systems (FC 507).
   Pyrophoric materials systems and facilities:
      1.   Storage (FC 6404).
      2.   Handling and use (FC 6405).
      3.   Storage, handling and use of silane gas (FC 6404 and 6405).
   Pyroxylin plastics systems and facilities (FC 6504).
   Roof access (altered roofs) (FC 504.4 and 504.5)
   Semiconductor fabrication facilities:
      1.   Facilities (FC 2703).
      2.   Fabrication areas (FC 2703).
      3.   Hazardous production material (HPM) rooms (FC 2703).
   Sprinkler systems where the design requirements are specified in this code (FC 2309, 3206, 3207, 3208, 3209, 3210, 5104, 5106 and 5704).
   Treatment systems for refrigerating systems using toxic or highly toxic refrigerants (FC 606).
   Unstable (reactive) materials systems and facilities:
      1.   Storage (FC 6604).
      2.   Handling and use (FC 6605).
   Vehicle tunnels and bridges (FC 322):
      1.   Emergency ventilation systems.
      2.   Emergency voice communication systems.
      3.   Means of egress.
      4.   Standpipe systems and other fire protection systems.
   Water-reactive solids and liquids systems and facilities:
      1.   Storage (FC 6704).
      2.   Handling and use (FC 6705).
   Yard hydrant systems (FC 507.2.3 and 5706.4.10.5).
105.4.1 Submissions.
Design and installation documents shall be submitted in such number and in such form and detail as may be prescribed by the commissioner. The design and installation documents shall be prepared by a registered design professional. The commissioner may require that such submissions be made in an approved electronic format or medium or online application.
   Exception: Design and installation documents for pre-engineered fire extinguishing systems for commercial cooking systems may be prepared by a licensed master fire suppression piping contractor.
(Am. L.L. 2018/195, 12/1/2018, eff. 5/30/2019)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2018/195.
105.4.2 Information on design and installation documents.
Design and installation documents shall be drawn to scale. Design and installation documents shall indicate the location, nature and extent of the work proposed and demonstrate compliance with the requirements of this code, the rules and other applicable laws, rules and regulations.
105.4.3 Approved documents required.
When department review of design and installation documents is required by this code or other laws, rules or regulations, it shall be unlawful to construct or alter any facility, or install, alter or remove any device, equipment or system, without first having obtained department approval of the design and installation documents.
(Am. L.L. 2018/195, 12/1/2018, eff. 5/30/2019)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2018/195.
105.4.4 Approved documents.
The department shall approve, or deny, or preliminarily deny design and installation documents in accordance with the procedures and time periods set forth in FC 105.2.4. Department approval of design and installation documents may be made subject to the requirements of the Building Code and other applicable laws, rules and regulations, and shall be documented and effective as set forth in this section.
(Am. L.L. 2018/195, 12/1/2018, eff. 5/30/2019)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2018/195.