Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
CHAPTER 15-4 BUREAU OF FIRE PREVENTION
CHAPTER 15-8 RESERVED*
CHAPTER 15-12 RESERVED*
CHAPTER 15-16 FIRE PROTECTION EQUIPMENT
CHAPTER 15-20 EXPLOSIVES AND FIREWORKS
CHAPTER 15-24 FLAMMABLE LIQUIDS
CHAPTER 15-26 FUME AND FLAMMABLE COMPRESSED GASES
CHAPTER 15-28 HAZARDOUS MATERIALS AND COMBUSTIBLE SOLIDS
ARTICLE I. GENERAL (15-28-010 et seq.)
ARTICLE II. HAZARDOUS CHEMICALS (15-28-040 et seq.)
ARTICLE III. OXIDIZING MATERIALS (15-28-200 et seq.)
ARTICLE IV. NITROMETHANE (15-28-230 et seq.)
ARTICLE V. ASPHALT, TAR, PITCH, RESIN AND PARAFFIN (15-28-260 et seq.)
ARTICLE VI. AMMONIUM NITRATE (15-28-300 et seq.)
ARTICLE VII. ORGANIC PEROXIDES (15-28-340 et seq.)
ARTICLE VIII. POTENTIALLY EXPLOSIVE CHEMICALS (15-28-360 et seq.)
ARTICLE IX. HIGHLY TOXIC MATERIALS (15-28-380 et seq.)
ARTICLE X. CORROSIVE LIQUIDS (15-28-390 et seq.)
ARTICLE XI. RADIOACTIVE MATERIALS (15-28-490 et seq.)
ARTICLE XII. COMBUSTIBLE SOLIDS (15-28-500 et seq.)
ARTICLE XIII. SMOKEHOUSES AND SMOKEROOMS (15-28-680 et seq.)
ARTICLE XIV. LUMBER DRY KILNS (15-28-710 et seq.)
ARTICLE XV. MISCELLANEOUS COMBUSTIBLES (15-28-730 et seq.)
ARTICLE XVI. MANUFACTURE, TRANSPORTATION OR SALE OF MATCHES (15-28-760 et seq.)
ARTICLE XVII. NITROCELLULOSE PRODUCTS (15-28-810 et seq.)
ARTICLE XVIII. NITROCELLULOSE (15-28-940 et seq.)
ARTICLE XIX. RESERVED (15-28-1000 et seq.)
ARTICLE XX. HAZARDOUS DUSTS (15-28-1050 et seq.)
ARTICLE XXI. UNDERGROUND STORAGE TANK VIOLATIONS. (15-28-1220 et seq.)
CHAPTER 15-30 RESERVED*
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
15-28-530 Ventilation.
   Every highly flammable material storage room and every picker or shredder room shall be provided with one or more windows, skylights or other ventilating opening facing a public way, private alley, yard or other open space not less than 15 feet wide, with closures arranged to open for natural ventilation and having a combined area of not less than five percent of the total wall area of the room. The required combined area of openings which are arranged to open for ventilation shall be provided with sashes or dampers, or other closures which shall be hung overbalanced and held in place in such manner that an explosion or fire within the room will cause such sash, damper or closure to open for its full area; provided, however, that in lieu of such requirements it shall be permissible to provide a vent flue or flues extending directly to the outside air, which shall be used solely for the purposes of ventilating such room, which shall have a combined area of not less than five percent of the total wall area of the room, with an inclosure of the same fire-resistive value as is required for the inclosures of the room, and equipped with a normally closed noncombustible trap door arranged to open automatically in case of explosion or fire within the room. No such window, skylight, ventilating opening or vent flue required by this section shall be nearer than four feet, six inches to any other building or structure on the same premises or to any interior lot line.
(Prior code §  92-42)
15-28-540 Fire protection equipment.
   Where a supply of steam at not less than five pounds pressure is available, a steam jet shall be installed in every picker or shredder room with a control valve outside of the room. Where such a supply of steam is not available, a standard two and one-half gallon fire extinguisher shall be kept outside the entrance door to every such room and adjacent thereto, with an opening 12 inches square provided through the inclosure of the room, through which the nozzle of the extinguisher may be directed into the room. Such opening shall be provided with a noncombustible cover, removable from the outside.
(Prior code §  92-43)
15-28-550 Instructions.
   Every valve required for the control of the discharge of steam through a steam jet in a picker or shredder room, shall be marked with a metal sign which shall bear the words "STEAM FIRE LINE". Every such sign shall meet the requirements of Section 15-28-120 for lettering.
(Prior code §  92-44)
15-28-560 Heating.
   In every picker or shredder room, all heating shall be by steam or hot water radiation equipped with guards as provided for a standard drying room.
(Prior code §  92-45)
15-28-570 Reserved.
Editor's note – Coun. J. 10-7-20, p. 21791, Art. VI, § 83, repealed § 15-28-570, which pertained to general construction requirements.
15-28-580 Danger signs.
   Every building or room for the use or storage of highly flammable materials, shall have the words "FLAMMABLE – KEEP FIRE AWAY" painted in a conspicuous position on the outside thereof. Such wording shall be in plainly legible bright red letters on a white background with letters not less than six inches high and with the principal strokes thereof not less than three-fourths inch in width.
(Prior code §  92-47)
15-28-590 General safety clearances.
   Two thousand five hundred cubic feet of loose highly flammable material may be stored in an entirely detached "loose" house. Such "loose" house shall be not nearer than 100 feet to any adjoining lot line except the minimum distance to any lot line on which a building containing a Group A, E, or I occupancy is situated shall be 200 feet. Such "loose" house shall be constructed of any suitable noncombustible materials with all openings properly protected against the entrance of sparks, flying brands or other fire hazard. Such "loose" house shall not be used for any other purpose.
(Prior code § 92-48; Amend Coun. J. 10-7-20, p. 21791, Art. VI, § 84)
Loading...