Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
Subdivision 3401 - General
CHAPTER 13-196 EXISTING BUILDINGS - MINIMUM REQUIREMENTS
13-196-010 Application.
13-196-020 Occupancy.
13-196-030 Structural stability.
13-196-031 Maintenance of exterior walls and enclosures - Definitions.
13-196-032 Maintenance of exterior walls and enclosures - Application.
13-196-033 Maintenance of exterior walls and enclosures - Critical examinations.
13-196-034 Maintenance of exterior walls and enclosures - Ongoing inspection and repair program.
13-196-035 Maintenance of exterior walls and enclosures - Reporting.
13-196-036 Maintenance of exterior walls - Retention of records at the building.
13-196-036.5 Reserved.
13-196-037 Maintenance of exterior walls and enclosures - Unsafe exterior walls and enclosures.
13-196-038 Rules and regulations.
13-196-038.5 Reserved.
13-196-039 Fines and penalties.
13-196-040 Floor loading.
13-196-050 Exit requirements.
13-196-060 Exits - Generally.
13-196-070 Exits - Types.
13-196-080 Passageways and exits to be unobstructed.
13-196-084 Stairwell re-entry in existing buildings.
13-196-085 Stairwell identification.
13-196-086 Area of rescue assistance identification.
13-196-090 Exit, stairway, fire escape and directional signs.
13-196-100 Smoke alarms - Where required.
13-196-110 Smoke alarms - Installation near sleeping rooms and in living levels.
13-196-120 Smoke alarms - Interior stairwell installation.
13-196-130 Smoke alarms - Standards.
13-196-140 Smoke alarms - Owner/tenant responsibilities.
13-196-150 Smoke alarms - Unlawful acts.
13-196-160 Reserved.
13-196-165 Carbon monoxide detectors.
13-196-170 Self-closing devices required for corridor doors.
13-196-180 Sprinkler systems - Where required.
13-196-190 Standpipe systems - Where required.
13-196-200 Standard fire alarm system requirements.
13-196-203 Life safety data sheet - Required.
13-196-204 Voice communication systems in existing buildings.
13-196-205 Automatic sprinkler system installation in existing high-rise buildings.
13-196-206 Life safety evaluation of existing high- rise buildings.
13-196-207 Materials and installation standards for retrofit fire protection systems.
13-196-208 Smokeproof towers in existing high- rise buildings - Fire shields.
13-196-209 High-rise buildings - Stairways - Doors - Frames.
13-196-210 High rise fire systems - Hotels.
13-196-220 Class II standard fire alarm systems.
13-196-230 Floor area and height.
13-196-240 Automatic fire detectors - Where required.
13-196-250 Permitted omission of sprinklers, heat and smoke detectors.
13-196-260 Fire extinguishers.
13-196-270 Elevator recall.
13-196-271 Continued operation.
13-196-280 Reserved.
13-196-290 Pre-ordinance hotels.
13-196-300 Institutional units.
13-196-310 Roominghouses.
13-196-320 Roominghouses - Sanitary facilities.
13-196-330 Roominghouses - Responsibility of operator.
13-196-340 Minimum requirements for residential buildings - General.
13-196-350 Residential buildings - Water closet.
13-196-360 Residential buildings - Lavatory.
13-196-370 Residential buildings - Bathtub or shower.
13-196-380 Residential buildings - Limitations on sharing sanitary facilities.
13-196-390 Residential buildings - Kitchen sink.
13-196-400 Residential buildings - Heating facilities.
13-196-410 Residential buildings - Heat to be furnished.
13-196-420 Residential buildings - Cold and hot water lines.
13-196-430 Residential buildings - Hot water to be furnished.
13-196-440 Gas-fired appliances.
13-196-450 Residential buildings - Hall and stairway lighting.
13-196-460 Residential buildings - Storage beneath stairways.
13-196-470 Residential buildings - Space, use and location - Applicability of provisions.
13-196-480 Residential buildings - Space requirements.
13-196-490 Residential buildings - Space requirements - Sleeping rooms.
13-196-500 Residential buildings - Access to water closets.
13-196-510 Residential buildings - Ceiling heights.
13-196-520 Residential buildings - Basement units.
13-196-530 Residential buildings - Foundations, exterior walls and roofs - Maintenance.
13-196-540 Residential buildings - Floors, interior walls and ceilings - Maintenance.
13-196-550 Residential buildings - Windows, doors and hatchways - Maintenance.
13-196-560 Residential buildings - Screens.
13-196-570 Residential buildings - Stairways and porches - Maintenance.
13-196-580 Residential buildings - Basements and cellars - Maintenance.
13-196-590 Residential buildings - Facilities, equipment, chimneys - Maintenance.
13-196-600 Residential buildings - Lot grading and drainage.
13-196-610 Residential buildings - Responsibilities of owners and occupants - General.
13-196-620 Residential buildings - Responsibilities of occupants.
13-196-630 Residential buildings - Responsibilities of owner or operator.
13-196-640 Residential buildings - Liability to city.
13-196-641 Application of certain sections.
13-196-650 Pre-ordinance conversion to existing buildings - Applicability.
13-196-660 Conversion of pre-ordinance buildings - Height limits.
13-196-670 Stairwells.
13-196-680 Corridors.
13-196-690 Dwelling separations.
13-196-700 Partitions.
13-196-710 Basement ceiling construction.
13-196-720 Heating plants.
13-196-730 Light and ventilation.
13-196-740 One additional dwelling unit over original allowed - Conditions.
13-196-750 Heat required.
13-196-760 Endangering health of employees.
Subdivision 3403 - Additions, Alterations or Repairs
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
13-196-420  Residential buildings – Cold and hot water lines.
   Every kitchen sink, lavatory and bathtub or shower required shall be connected with hot and cold water lines. The hot water lines shall be connected with water heating facilities which are capable of heating water to such a temperature as to permit water to be drawn at every required outlet at a temperature of not less than 120 degrees Fahrenheit even when the heating facilities required by this Code are not in operation.
(Prior code § 78-40)
13-196-430  Residential buildings – Hot water to be furnished.
   Every family unit or rooming unit to which hot water is furnished from water heating facilities used in common shall be supplied with hot water throughout the year so that the occupants may draw water at every hot water outlet between the hours of 6:00 a.m. and 10:30 p.m. of a minimum temperature of 120 degrees Fahrenheit.
(Prior code § 78-41)
13-196-440  Gas-fired appliances.
   All gas-fired heating, cooking and other appliances and gas-fired water heaters, shall conform to the requirements in Chapter 18-28 of the building provisions of this Code concerning installation, vents and flues.
(Prior code § 78-42; Amend Coun. J. 11-9-16, p. 36266, § 26)
13-196-450  Residential buildings – Hall and stairway lighting.
   Every public hall and stairway in every dwelling having more than one family unit shall be adequately lighted at all times, except that in a two-family dwelling an adequate lighting system which may be turned on when needed by conveniently located light switches shall be permitted instead of a full-time lighting system.
(Prior code § 78-43)
13-196-460  Residential buildings – Storage beneath stairways.
   There shall be no closets or storage of any kind beneath stairways in any dwelling containing two or more family units or in any roominghouse unless the stair complies with the fire resistive requirements of Sections 15-8-120 to 15-8-180 inclusive, or unless the stairs and storage space are separated by noncombustible materials having a fire rating of not less than one hour. No combustible or flammable materials, fluids, or compounds shall be placed, stored or kept in any place inside or outside of any building where the ignition or burning of such materials, fluids, or compounds would obstruct or render hazardous the egress from any family unit or from the building.
(Prior code § 78-44)
Loading...